RG-S6580 Series Data Center Switches
“
Specifications
- Model Options: RG-S6580-48CQ8QC,
RG-S6580-24DC8QC - Ports:
- RG-S6580-48CQ8QC: 48 100GE DSFP ports, 8 400GE QSFP-DD
ports - RG-S6580-24DC8QC: 24 200GE QSFP56 ports, 8 400GE QSFP-DD
ports
- RG-S6580-48CQ8QC: 48 100GE DSFP ports, 8 400GE QSFP-DD
- Switching Capacity: 16.0 Tbps
- Packet Forwarding Rate: 5350 Mpps
- VLAN Support: 802.1Q VLAN
- Dimensions:
- RG-S6580-48CQ8QC: 442 mm x 700 mm x 44 mm, 11.5 kg
- RG-S6580-24DC8QC: 442 mm x 670.8 mm x 43.6 mm, 11 kg
Product Usage Instructions
Installation
- Ensure the switch is powered off before installation.
- Mount the switch in a rack using appropriate mounting
brackets. - Connect power inputs as per the specified voltage
requirements.
Configuration
To configure the switch:
- Connect to the switch using the console port and a terminal
emulator. - Access the CLI interface to configure settings such as VLANs,
port configurations, and management options.
Management
The switch supports various management interfaces:
- Console Port
- Management Interface
- USB Interface
FAQ
Q: What are the available model options for the RG-S6580 series
switches?
A: The available model options are
RG-S6580-48CQ8QC and RG-S6580-24DC8QC.
Q: What are the key features of the RG-S6580 series
switches?
A: The switches offer high-density ports
(100GE, 200GE, and 400GE), low-latency networking, carrier-class
reliability, IPv4/IPv6 dual-stack support, and robust management
capabilities.
Q: How can I manage the RG-S6580 series switch?
A: The switch supports CLI-based management,
telnet, cluster management, SNMP v1/v2c/v3, SSH2.0, and SSL for
secure management.
“`
Ruijie RG-S6580 Series Switch Datasheet
CONTENT
Overview………………………………………………………………………………………………………………………………………………..2 Appearance ……………………………………………………………………………………………………………………………………………2 Product Highlights ……………………………………………………………………………………………………………………………………2 Specifications …………………………………………………………………………………………………………………………………………4 Configuration Guide…………………………………………………………………………………………………………………………………..7
Contact Us
Tel: +852-63593631 (Hong Kong) Email: sales@network-switch.com (Sales Inquiries) ccie-support@network-switch.com (CCIE Technical Support)
Network-switch.com
1
OVERVIEW
The RG-S6580 series switches are new-generation high-performance and high-density switches released by Ruijie Networks for AI and other application scenarios. The switches are highlighted by the high performance and high density. The switches provide high-density 200GE or 100GE ports and can be used with the RG- S6980-64QC switch to meet design requirements of the spine-leaf network architecture.
There are two models available: RG-S6580-48CQ8QC: 48 100GE DSFP ports and eight 400GE QSFP-DD ports RG-S6580-24DC8QC: 24 200GE QSFP56 ports and eight 400GE QSFP-DD ports.
APPEARANCE
RG-S6580-48CQ8QC Front
RG-S6580-48CQ8QC Rear
RG-S6580-24DC8QC Front
RG-S6580-24DC8QC
Product highlights
Next-Generation Data Center Network
The rapid development of AI/machine learning, and other applications drives the evolution of the next-generation data center network to the 100GE/400GE network. The next-generation data center network requires switches to have higher performance and bandwidth within a specific space. With a height of 1 RU, the RG-S6580 series switches provide a maximum of 48 100GE ports (or 24 200GE ports) and eight 400GE ports, which better meets the evolution requirements of the next-generation data center network.
Network-switch.com
2
High-Performance and Low-Delay Data Center Network
The RG-S6580 series switches can work with the RG-S6980-64QC switch to build end-to-end, lossless, lowlatency remote direct memory access (RDMA) networks based on priority-based flow control (PFC), explicit congestion notification (ECN), and other network flow control technologies as well as the memory management unit (MMU) technology. It meets network deployment requirements in various scenarios including AI/machine learning, high performance computing, distributed storage, and big data.
Carrier-Class Reliability Protection
The RG-S6580 series switches support 1+1 power redundancy and 5+1 fan redundancy. All power supply modules and fan modules can be hot-swapped without affecting the normal operation of the switch. The switch provides fault detection and alarm functions for power supply modules and fans. It automatically adjusts the fan speed based on temperature changes, to better adapt to the environment in data centers. The switch also supports device-level and link-level reliability protection as well as overcurrent protection, overvoltage protection and overheating protection.
IPv4/IPv6 Dual-Stack Protocols and Multilayer Switching
The hardware of the RG-S6580 series switches supports IPv4 and IPv6 protocol stacks and multilayer line-rate switching. The hardware differentiates and processes IPv4 and IPv6 packets. The switch also integrates multiple tunneling technologies such as manual tunneling. Users can flexibly work out IPv6 inter-network communication solutions by using this switch based on IPv6 network planning and network conditions. The RG-S6580 series switches support a wide range of IPv4 routing protocols, including static routing, Routing Information Protocol (RIP), RIPv2, Open Shortest Path First (OSPF), and Border Gateway Protocol version 4 (BGP4). Users can select appropriate routing protocols based on network environments, to flexibly build networks. The switch also supports abundant IPv6 routing protocols, including static routing, Routing Information Protocol next generation (RIPng), OSPFv3, and BGP4+. Appropriate routing protocols can be selected to upgrade an existing network to an IPv6 network or build a new IPv6 network.
All-Round Management Performance
The switch provides various management interfaces such as the console interface, management interface, and USB interface, and supports Simple Network Management Protocol (SNMP) v1/v2c/v3 and universal network management platform. It supports CLI-based management, telnet, and cluster management, which facilitates device management. The supported encryption modes such as SSH2.0 and SSL ensure more secure management.
Network-switch.com
3
Technical Specifications
Hardware Specifications
System Specifications
System Specifications
RG-S6580-48CQ8QC
RG-S6580-24DC8QC
Ports Expansion Modules Expansion Module Slots Management Port Switching Capacity Packet Forwarding Rate 802.1Q VLAN
48 × 100GE ports (DSFP) + 8 × 400GE ports (QSFP-DD)
Not supported
24 × 200GE ports (QSFP56) + 8 × 400GE ports (QSFP-DD)
Two power supply module slots (1+1 redundancy) Six fan module slots (5+1 redundancy; the system needs at least 5 fan modules are required)
One management port, one console port, and one USB port, compliant with the USB2.0 standard 16.0 Tbps
5350 Mpps
4094
Dimensions
Dimensions
RG-S6580-48CQ8QC
RG-S6580-24DC8QC
Dimensions (W × D × H) Weight
442 mm x 700 mm x 44 mm (17.40 in. x 27.56 in. x 1.73 in., 1 RU)
Chassis with six fan modules and two power supply modules: 11.5 kg (25.35 lbs.)
442 mm x 670.8 mm x 43.6 mm (17.40 in. x 26.41 in. x 1.72 in., 1 RU)
Chassis with six fan modules and two power supply modules: 11 kg (24.25 lbs.)
Power Supply and Consumption
Power Supply and Consumption
RG-S6580-48CQ8QC
RG-S6580-24DC8QC
Power Input
AC input
RG-PA1200I-F module
Rated voltage: 110 V AC/220 V AC
Rated voltage range: 100 V AC to 127 V AC (50 Hz to 60 Hz), rated current: 13.8 A Rated voltage range: 200 V AC to 240 V AC (50 Hz to 60 Hz), rated current: 8.5 A Max voltage range: 90 V AC to 264 V AC (47 Hz to 63 Hz) HVDC input
RG-PA1200I-F module
Rated voltage: 240 V DC
Max voltage range: 180 V DC to 300 V DC Max input current: 6.5 A
Maximum Power Consumption
Max: 742 W Typical: 633 W Static: 178 W
Max: 850 W Typical: 700 W Static: 300 W
Network-switch.com
4
Environment and Reliability
Environment and Reliability
RG-S6580-48CQ8QC
Temperature Alarm
Temperature alarms and overheat protection
Operating Temperature
0ºC to 40ºC (32ºF to 104ºF)
Storage Temperature
40°C to +70°C (40ºF to +158ºF)
Operating Humidity
10% RH to 90% RH (non-condensing)
Storage humidity
5% to 95% RH (non-condensing)
Working altitude
Operating altitude: up to 5000 m (16,404.20 ft.) Storage altitude: up to 5000 m (16,404.20 ft.)
RG-S6580-24DC8QC
Software Specifications
Software Specifications
RG-S6580-48CQ8QC
RG-S6580-24DC8QC
L2 Protocols L3 Protocols (IPv4) IPv6 Basic Protocols IPv6 Features
ACL
IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP),Jumbo Frame (9 KB)
BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, Policy-based Routing (PBR), route-policy, EqualCost Multi-Path Routing (ECMP), WCMP, VRRP
Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS
Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+
ACL 80ACL-based Redirection IPv6 ACL Extended/Standard IP/MAC-based ACL Time-based ACLGlobal ACL When an ACL is applied to different physical interfaces or SVIs, resources can be shared.ACL CounterACL Counter OnlyACL Logging Diplaying ACL Resource UsageExpert- level ACL IPv4 UDF ACLGlobal ACL Counter OnlyMatching Against the Inner 5-Tuple of the VXLANIPv6 UDF ACL Matching Against the Inner 5-Tuple of the Passing VXLANIngress/Egress ACLs
ACL80 ACL – based redirectionIPv6 ACL Extended/Standard IP ACLExtended MAC ACL Time-based ACL Global ACL Resource sharing in the case of applying an ACL on different physical ports or SVIs ACL counter ACL counter only ACL loggingDisplaying ACL resource usageACL- based re-marking Expert-level ACLIPv4 user- defined function(UDF) ACLConfiguring ACL counteronly globallyACL matching against the inner 5-tuple of VXLAN packetsIPv6 UDF ACL ACL matching against the inner 5-tuple of packets passing through the VXLAN
Data Center Features
PFC, ECN, and other data center features RDMA
Visualization
gRPC sFlow sampling
Network-switch.com
5
Software Specifications
RG-S6580-48CQ8QC
RG-S6580-24DC8QC
QoS
Mapping of IEEE 802.1p, DSCP, and ToS priorities ACL-based traffic classification Priority marking/remarking
Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR Congestion avoidance mechanisms such as WRED and tail discarding
HA Design
Security Features Management Mode Other Protocols
GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules
Network foundation protection policy (NFPP), CPP, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, broadcast packet suppression, hierarchical user management
SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, syslog, SPAN/RSPAN/ ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and temperature alarm
DHCP client, DHCP relay, DHCP server, DNS client, ARP proxy, and Syslog
Safety and Regulatory Compliance
Specifications
RG-S6580-48CQ8QC
Safety
IEC 62368-1 EN 62368-1 BS EN 62368-1 GB 4943.1
RG-S6580-24DC8QC GB 4943.1
Electromagnetic Compatibility (EMC)
EN 55032
BS EN 55032 EN 55035 BS EN 55035 EN 61000-3-2 EN 610003-3 BS EN 61000-3-2 BS EN 61000-3-3 EN 300 386 GB/T 9254.1
GB/T 9254.1 VCCI-CISPR 32:2016
Environment
2011/65/EU EN 50581 2012/19/EU EN 2011/65/EU EN 50581 2012/19/EU EN
50419 (EC) No.1907/2006
50419 (EC) No.1907/2006
GB/T 26572
GB/T 26572
*For more country-specific regulatory information and approvals, contact your local sales agency.
Network-switch.com
6
Configuration Guide
The configuration procedure for RG-S6580 series switches is as follows:
*Select the switch (installed with all fan and power supply modules) *Select optical transceivers based on port requirements
NETWORK-SWITCH. COM ORDERING INFORMATION
Chassis, Fan Module
Product Model
Description
RG-S6580-48CQ8QC
48 × 100GE DSFP ports + 8 × 400GE QSFP-DD ports Two power slots and six fan slots The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules.
RG-S6580-24DC8QC
24 × 200GE QSFP56 ports + 8 × 400GE QSFP-DD ports Two power slots and six fan slots The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules.
Power Supply Module
Product Model
RG-PA1200I-F
Description 1200 W AC module (AC/240 V HVDC)
Fan Module
Product Model
M1HFAN II-F
Description Fan module (front-to-rear ventilation)
400GBASE Series Optical Modules
Product Model
Description
400G-QDD-SR8-MM850 400G-QDD-DR4-SM1310 400G-QDD-FR4-SM1310
400G SR8 module, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF
400G DR4 module, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF 400G FR4 module, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF
Network-switch.com
7
100G BASE Series Optical Modules
Product Model
Description
100G-AOC-5M 100G-AOC-10M 100G-QSFP-SR-MM850 100G-QSFP-iLR4-SM1310 100G-QSFP-LR4-SM1310 100G-QSFP-ER4-SM1310
100G QSFP28 AOC cable, 5 m (16.40 ft.)
100G QSFP28 AOC cable, 10 m (32.81 ft.)
100G SR module, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF
100G iLR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF
100G LR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF 100G ER4 module, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF
Network-switch.com
8
Documents / Resources
![]() |
Ruijie RG-S6580 Series Data Center Switches [pdf] Owner's Manual RG-S6580 Series, RG-S6580 Series Data Center Switches, Data Center Switches, Switches |