Owner's Manual for Ruijie models including: RG-S6580 Series, RG-S6580 Series Data Center Switches, Data Center Switches, Switches
Ruijie RG-S6580 Series 24-Port 200GE & 8-Port 400GE Switch | Network-Switch – Network-Switches
File Info : application/pdf, 9 Pages, 491.54KB
DocumentDocumentRuijie RG-S6580 Series Switch Datasheet CONTENT Overview....................................................................................................................................................................2 Appearance ...............................................................................................................................................................2 Product Highlights ......................................................................................................................................................2 Specifications ............................................................................................................................................................4 Configuration Guide.....................................................................................................................................................7 Contact Us Tel: +852-63593631 (Hong Kong) Email: sales@network-switch.com (Sales Inquiries) ccie-support@network-switch.com (CCIE Technical Support) Network-switch.com 1 OVERVIEW The RG-S6580 series switches are new-generation high-performance and high-density switches released by Ruijie Networks for AI and other application scenarios. The switches are highlighted by the high performance and high density. The switches provide high-density 200GE or 100GE ports and can be used with the RG- S6980-64QC switch to meet design requirements of the spine-leaf network architecture. There are two models available: RG-S6580-48CQ8QC: 48 100GE DSFP ports and eight 400GE QSFP-DD ports RG-S6580-24DC8QC: 24 200GE QSFP56 ports and eight 400GE QSFP-DD ports. APPEARANCE RG-S6580-48CQ8QC Front RG-S6580-48CQ8QC Rear RG-S6580-24DC8QC Front RG-S6580-24DC8QC Product highlights Next-Generation Data Center Network The rapid development of AI/machine learning, and other applications drives the evolution of the next-generation data center network to the 100GE/400GE network. The next-generation data center network requires switches to have higher performance and bandwidth within a specific space. With a height of 1 RU, the RG-S6580 series switches provide a maximum of 48 100GE ports (or 24 200GE ports) and eight 400GE ports, which better meets the evolution requirements of the next-generation data center network. Network-switch.com 2 High-Performance and Low-Delay Data Center Network The RG-S6580 series switches can work with the RG-S6980-64QC switch to build end-to-end, lossless, lowlatency remote direct memory access (RDMA) networks based on priority-based flow control (PFC), explicit congestion notification (ECN), and other network flow control technologies as well as the memory management unit (MMU) technology. It meets network deployment requirements in various scenarios including AI/machine learning, high performance computing, distributed storage, and big data. Carrier-Class Reliability Protection The RG-S6580 series switches support 1+1 power redundancy and 5+1 fan redundancy. All power supply modules and fan modules can be hot-swapped without affecting the normal operation of the switch. The switch provides fault detection and alarm functions for power supply modules and fans. It automatically adjusts the fan speed based on temperature changes, to better adapt to the environment in data centers. The switch also supports device-level and link-level reliability protection as well as overcurrent protection, overvoltage protection and overheating protection. IPv4/IPv6 Dual-Stack Protocols and Multilayer Switching The hardware of the RG-S6580 series switches supports IPv4 and IPv6 protocol stacks and multilayer line-rate switching. The hardware differentiates and processes IPv4 and IPv6 packets. The switch also integrates multiple tunneling technologies such as manual tunneling. Users can flexibly work out IPv6 inter-network communication solutions by using this switch based on IPv6 network planning and network conditions. The RG-S6580 series switches support a wide range of IPv4 routing protocols, including static routing, Routing Information Protocol (RIP), RIPv2, Open Shortest Path First (OSPF), and Border Gateway Protocol version 4 (BGP4). Users can select appropriate routing protocols based on network environments, to flexibly build networks. The switch also supports abundant IPv6 routing protocols, including static routing, Routing Information Protocol next generation (RIPng), OSPFv3, and BGP4+. Appropriate routing protocols can be selected to upgrade an existing network to an IPv6 network or build a new IPv6 network. All-Round Management Performance The switch provides various management interfaces such as the console interface, management interface, and USB interface, and supports Simple Network Management Protocol (SNMP) v1/v2c/v3 and universal network management platform. It supports CLI-based management, telnet, and cluster management, which facilitates device management. The supported encryption modes such as SSH2.0 and SSL ensure more secure management. Network-switch.com 3 Technical Specifications Hardware Specifications System Specifications System Specifications RG-S6580-48CQ8QC RG-S6580-24DC8QC Ports Expansion Modules Expansion Module Slots Management Port Switching Capacity Packet Forwarding Rate 802.1Q VLAN 48 × 100GE ports (DSFP) + 8 × 400GE ports (QSFP-DD) Not supported 24 × 200GE ports (QSFP56) + 8 × 400GE ports (QSFP-DD) Two power supply module slots (1+1 redundancy) Six fan module slots (5+1 redundancy; the system needs at least 5 fan modules are required) One management port, one console port, and one USB port, compliant with the USB2.0 standard 16.0 Tbps 5350 Mpps 4094 Dimensions Dimensions RG-S6580-48CQ8QC RG-S6580-24DC8QC Dimensions (W × D × H) Weight 442 mm x 700 mm x 44 mm (17.40 in. x 27.56 in. x 1.73 in., 1 RU) Chassis with six fan modules and two power supply modules: 11.5 kg (25.35 lbs.) 442 mm x 670.8 mm x 43.6 mm (17.40 in. x 26.41 in. x 1.72 in., 1 RU) Chassis with six fan modules and two power supply modules: 11 kg (24.25 lbs.) Power Supply and Consumption Power Supply and Consumption RG-S6580-48CQ8QC RG-S6580-24DC8QC Power Input AC input RG-PA1200I-F module Rated voltage: 110 V AC/220 V AC Rated voltage range: 100 V AC to 127 V AC (50 Hz to 60 Hz), rated current: 13.8 A Rated voltage range: 200 V AC to 240 V AC (50 Hz to 60 Hz), rated current: 8.5 A Max voltage range: 90 V AC to 264 V AC (47 Hz to 63 Hz) HVDC input RG-PA1200I-F module Rated voltage: 240 V DC Max voltage range: 180 V DC to 300 V DC Max input current: 6.5 A Maximum Power Consumption Max: 742 W Typical: 633 W Static: 178 W Max: 850 W Typical: 700 W Static: 300 W Network-switch.com 4 Environment and Reliability Environment and Reliability RG-S6580-48CQ8QC Temperature Alarm Temperature alarms and overheat protection Operating Temperature 0ºC to 40ºC (32ºF to 104ºF) Storage Temperature 40°C to +70°C (40ºF to +158ºF) Operating Humidity 10% RH to 90% RH (non-condensing) Storage humidity 5% to 95% RH (non-condensing) Working altitude Operating altitude: up to 5000 m (16,404.20 ft.) Storage altitude: up to 5000 m (16,404.20 ft.) RG-S6580-24DC8QC Software Specifications Software Specifications RG-S6580-48CQ8QC RG-S6580-24DC8QC L2 Protocols L3 Protocols (IPv4) IPv6 Basic Protocols IPv6 Features ACL IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP),Jumbo Frame (9 KB) BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, Policy-based Routing (PBR), route-policy, EqualCost Multi-Path Routing (ECMP), WCMP, VRRP Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+ ACL 80ACL-based Redirection IPv6 ACL Extended/Standard IP/MAC-based ACL Time-based ACLGlobal ACL When an ACL is applied to different physical interfaces or SVIs, resources can be shared.ACL CounterACL Counter OnlyACL Logging Diplaying ACL Resource UsageExpert- level ACL IPv4 UDF ACLGlobal ACL Counter OnlyMatching Against the Inner 5-Tuple of the VXLANIPv6 UDF ACL Matching Against the Inner 5-Tuple of the Passing VXLANIngress/Egress ACLs ACL80 ACL - based redirectionIPv6 ACL Extended/Standard IP ACLExtended MAC ACL Time-based ACL Global ACL Resource sharing in the case of applying an ACL on different physical ports or SVIs ACL counter ACL counter only ACL loggingDisplaying ACL resource usageACL- based re-marking Expert-level ACLIPv4 user- defined function(UDF) ACLConfiguring ACL counteronly globallyACL matching against the inner 5-tuple of VXLAN packetsIPv6 UDF ACL ACL matching against the inner 5-tuple of packets passing through the VXLAN Data Center Features PFC, ECN, and other data center features RDMA Visualization gRPC sFlow sampling Network-switch.com 5 Software Specifications RG-S6580-48CQ8QC RG-S6580-24DC8QC QoS Mapping of IEEE 802.1p, DSCP, and ToS priorities ACL-based traffic classification Priority marking/remarking Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR Congestion avoidance mechanisms such as WRED and tail discarding HA Design Security Features Management Mode Other Protocols GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules Network foundation protection policy (NFPP), CPP, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, broadcast packet suppression, hierarchical user management SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, syslog, SPAN/RSPAN/ ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and temperature alarm DHCP client, DHCP relay, DHCP server, DNS client, ARP proxy, and Syslog Safety and Regulatory Compliance Specifications RG-S6580-48CQ8QC Safety IEC 62368-1 EN 62368-1 BS EN 62368-1 GB 4943.1 RG-S6580-24DC8QC GB 4943.1 Electromagnetic Compatibility (EMC) EN 55032 BS EN 55032 EN 55035 BS EN 55035 EN 61000-3-2 EN 610003-3 BS EN 61000-3-2 BS EN 61000-3-3 EN 300 386 GB/T 9254.1 GB/T 9254.1 VCCI-CISPR 32:2016 Environment 2011/65/EU EN 50581 2012/19/EU EN 2011/65/EU EN 50581 2012/19/EU EN 50419 (EC) No.1907/2006 50419 (EC) No.1907/2006 GB/T 26572 GB/T 26572 *For more country-specific regulatory information and approvals, contact your local sales agency. Network-switch.com 6 Configuration Guide The configuration procedure for RG-S6580 series switches is as follows: *Select the switch (installed with all fan and power supply modules) *Select optical transceivers based on port requirements NETWORK-SWITCH. COM ORDERING INFORMATION Chassis, Fan Module Product Model Description RG-S6580-48CQ8QC 48 × 100GE DSFP ports + 8 × 400GE QSFP-DD ports Two power slots and six fan slots The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules. RG-S6580-24DC8QC 24 × 200GE QSFP56 ports + 8 × 400GE QSFP-DD ports Two power slots and six fan slots The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules. Power Supply Module Product Model RG-PA1200I-F Description 1200 W AC module (AC/240 V HVDC) Fan Module Product Model M1HFAN II-F Description Fan module (front-to-rear ventilation) 400GBASE Series Optical Modules Product Model Description 400G-QDD-SR8-MM850 400G-QDD-DR4-SM1310 400G-QDD-FR4-SM1310 400G SR8 module, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF 400G DR4 module, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF 400G FR4 module, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF Network-switch.com 7 100G BASE Series Optical Modules Product Model Description 100G-AOC-5M 100G-AOC-10M 100G-QSFP-SR-MM850 100G-QSFP-iLR4-SM1310 100G-QSFP-LR4-SM1310 100G-QSFP-ER4-SM1310 100G QSFP28 AOC cable, 5 m (16.40 ft.) 100G QSFP28 AOC cable, 10 m (32.81 ft.) 100G SR module, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF 100G iLR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF 100G LR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF 100G ER4 module, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF Network-switch.com 8