Command format: VSET<X>:<NR2>

  1. VSET: Command header
  2. X: output channel
  3. separator
  4. NR2: parameter
Command Details:
  1. ISET<X>:<NR2>
    Description: Sets the output current.
    Example: ISET1 :2.225
    Sets the CH 1 output current to 2.225A
  2. ISET<X>?
    Description: Returns the output current setting.
    Example: ISET1?
    Returns the CH 1 output current setting
  3. VSET<X>:<NR2>
    Description: Sets the output voltage. Example:
    VSET1:20.50
    Sets the CH 1 voltage to 20.S0V
  4. VSET<X>?
    Description: Returns the output voltage setting.
    Example: VSET1?
    Returns the CH1 voltage setting.
  5. IOUT<X>?
    Description: Returns the actual output current.
    Example: IOUT1?
    Returns the CH1 output current
  6. VOUT<X>?
    Description: Returns the actual output voltage.
    Example: VOUT1?
    Returns the CH 1 output voltage
  7.  BEEP<Boolean>
    Description: Turns on or off the beep. Boolean: boolean logic.
    Example: BEEP1 Turns on the beep.
  8. OUT<Boolean>
    Description: Turns on-off the output.
    Boolean: 0 OFF, 1 ON
    Example: OUT1 Turns on the output
  9. STATUS?
    Description: Returns the POWER SUPPLY status.
    Contents 8 bits in the following format
    Bit Item Description
    0 When output is ON,0=CC mode, 1 =CVmode
    4 Beep 0=Off, 1 =On
    5 OCP 0=Off, 1 =On
    6 Output 0=Off, 1 =On
    7 OVP 0=Off, 1 =On
  10. * IDN?
    Description: Returns the RND 320-KA3005P identification.
    Example *IDN?
    Contents RND 320-KA3005P V1 .3 (Manufacturer, model name,).
  11. RCL<NR1>
    Description: Recalls a panel setting.
    NR 1 1-5: Memory numbers 1 to 5
    Example RCL 1 Recalls the panel setting stored in memory number1
  12. SAV<NR1>
    Description: Stores the panel setting.
    NR 1 1-5: Memory numbers 1 to 5
    Example SAV1 Stores the panel setting stored in memory number1
  13. OCP< Boolean >
    Description: Stores the panel setting.
    Boolean: 0 OFF, 1 ON
    Example: OCP1 Turns on the OCP
  14. OVP< Boolean >
    Description: Turns on the OVP.
    Boolean: 0 OFF, 1 ON
    Example: OVP1 Turns on the OVP