SCT-1100
Quick Setup Guide
Key Functions
Key | Function |
![]() |
In setup: scroll forward through parameters In numeric input: decreases digit to be modified |
![]() |
In setup: scroll back through the functions In numeric input: increases digit to be modified |
![]() |
In setup: quickly position the first step of a menu In numeric input: selects digit to be modified, from left to right |
![]() |
In setup: enter into a parameter or to confirm asetting In numeric input: confirms the entry made |
C ON/OFF | Turn the instrument on/off In setup: exit a step without confirming the setting In numeric input: clears the present value |
- Press the ON/OFF key (C) to turn the instrument on.
- Press the mode key (
) when the firmware version displays to enter the setup menu.
- Press the print key (
) in the setup menu to view/select the parameter choices.
Note
When settings are complete press C until the indicator displays . Press
to save set up and return to weigh mode. Pressing any other key exits the setup and discards changes.
Wiring Diagram
Pin Number | Label | Description |
VE 12-24 VDC Power Supply | ||
1 | +VDC | +12-24 VDC |
2 | GND | 0 VDC (GND) |
Inputs and Outputs | ||
Optoisolated Inputs Positive Logic (12-24 VDC, 5-20 mA max) | ||
3 | COM | Common Output |
4 | IN1 | Input 1 |
5 | IN2 | Input 2 |
Relays | ||
6 | RL1 | Relay 1 |
7 | RL2 | Relay 2 |
8 | COM | Common Relay |
Analog Output | ||
Voltage | ||
9 | I+ | +20 mA |
10 | I- | -0 mA (GND) |
Current | ||
11 | V+ | +10 V |
12 | V- | 0 V (GND) |
Serial Port | ||
RS-485 | ||
13 | (A) 485 + Line | |
14 | (B) 485 – Line | |
RS-232 | ||
15 | TX | Transmission |
16 | RX | Reception |
17 | GND | Ground |
Load Cell 1 | ||
18 | SIG+ | Signal + |
19 | SIG- | Signal- |
20 | SEN+ | Sense + |
21 | SEN- | Sense- |
22 | EXC+ | Excitation + |
23 | EXC- | Excitation – |
Load Cell 2 | ||
24 | SIG+ | Signal + |
25 | SIG- | Signal – |
26 | EXC+ | Excitation + |
27 | EXC- | Excitation – |
Load Cell 3 | ||
28 | SIG+ | Signal + |
29 | SIG- | Signal – |
30 | EXC+ | Excitation + |
31 | EXC- | Excitation – |
Load Cell 4 | ||
32 | SIG+ | Signal + |
33 | SIG- | Signal- |
34 | EXC+ | Excitation + |
35 | EXC- | Excitation – |
230 W. Coleman St.
Rice Lake, WI 54868
USA USA: 800-472-6703
International: +1-715-234-9171
© Rice Lake Weighing Systems
Content subject to change without notice.
www.ricelake.com
PN 185438 Rev B
Documents / Resources
![]() |
RICE LAKE WEIGHING SYSTEMS SCT-1100 Signal Conditioning Transmitter [pdf] User Guide SCT-1100 Signal Conditioning Transmitter, Signal Conditioning Transmitter, Conditioning Transmitter, Transmitter |