User Manual
RFID reader with access
control
SecureEntry-CR40
Specifications:
- Warranty: 1 year
- RFID Card Supported: 125 kHz
- Device Type: Access Control RFID Card Reader
- Interface: Wiegand 26
- Verification Type: RFID Card
- Access Control: Yes
- Voltage: 9~24V DC
- Ingress protection: IP66
- Reading Distance: > 3cm
- Operating current: 25 mA
- Operating temperature: -40°C~60°C
- Operating humidity: 10% to 95%
- Product dimensions: 105 x 20 mm
- Package dimensions: 103 x 48 x 19 mm
- Product weight: 180 g
- Product weight with packaging: 260 g
Set contents:
- RFID reader with access control
- Screws and mounting plugs
- Manual
Features:
- The RFID reader can be combined with an electric lock, thanks to which we will obtain a device that allows us to manage access to rooms and buildings.
- The device supports RFID cards with 125 kHz frequencies
- The access control system has a water-resistant housing with IP66 protection, so it can be installed outdoors.
- The reader is equipped with a Wiegand 26 interface, which allows it to be connected to a time recorder and transfer data.
Installation
- Drill 2 holes in the wall for screws (A, C) and one hole for wire (B)
- Drive the rubber pins into the holes (A, C)
- Attach the back cover to the wall with 2 screws
- Insert the wire through the cable hole (B)
- Attach the device to the back cover
Function Table
Reading the card | The LED will turn green and the buzzer will beep, meanwhile, the reader will send a Wiegand signal. |
External LED Control | When the input voltage for the LED is low, the LED will turn green |
External buzzer control | When the input voltage for the buzzer is low, the buzzer will make a sound |
Wiegand Data Output | The factory default setting is 26 bits. |
Wiring Diagram
Colour | Function | Comments |
Red | Power | +DC (9-24V) |
Black | GND | Ground |
Green | D0 | Data 0 |
White | D1 | Data 1 |
Brown | LED | Green LED control |
Yellow | Buzzer | Buzzer control |
(Note: The brown and yellow wires are optional connections.)
Data Signal
Description | Reader Typical Time |
Pulse Duration | 42 μS |
Pulse Interval Time | 2 mS |
The table above shows the waveform of time, pulse width (pulse duration), and interval time (time between pulses) of Wiegand data sent from readers. (Example 1010)
Documents / Resources
![]() |
RFID SecureEntry-CR40 Reader with Access Control [pdf] User Manual SecureEntry-CR40 Reader with Access Control, Reader with Access Control, Access Control, Control |