FP2070 SERIES
QUICK START GUIDE
FP2070 SERIES Analog Resistive Touch Screen
Product Code
FP2070T-V2: 800 x 480, WVGA, 7” color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port & 1 USB Host port.
FP2070TN-V2: 800 x 480, WVGA, 7” color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port, one USB Host port & 1 Ethernet Port.
FP2070T-E: 800 x 480, WVGA, 7” color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port & 1 USB Host port. It supports upto 3 expansions.
FP2070TN-E: 800 x 480, WVGA, 7” color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port, one USB Host port & 1 Ethernet Port. It supports upto 3 expansions.
GETTING STARTED
User should follow the given sequence to configure and use any FlexiPanels series unit:
- Install FlexiSoft Software.
- Create a PZM application using FlexiSoft software.
- Connect programming cable.
- Download Firmware i.e. driver for the HMI.
- Download application.
- Now FP unit is ready to use in the system.
SPECIFICATIONS
Power (Base) | 24VDC (+20%) @200mA, 4.8W (T-V2 module) 24VDC (+20%, -15%) @230mA, 5.52W(TN-V2 module) |
Power (With 3 Expansions) |
24VDC (+20%) @220mA, 5.28W (T-E type module) 24VDC (+20%) @250mA, 6W (TN-E type module) |
Display | 7”, 800 x 480 pixels, WVGA color TFT with 4-wire analog resistive touch screen |
LEDs | 1 |
RAM | 32MB max. |
User Application | 8MB |
Ladder Memory | 2MB |
Alarm Memory | 1350 Alarms |
Retentive Memory | 8000 Words |
Data Log | 4MB |
Keep Memory Registers | 1000 Words |
Panel Cutout | 127.00(H) x 175.00(W)mm |
Dimensions | 138(H) x 186.0(W) x 31.0(D)mm |
Weight | Approx. 400gm |
Communication | |
Serial Ports | 2 x RS232 /RS485 |
USB Ports | 1 USB Type C & 1 USB Host |
SD card # | Micro SD card supported (4 to 32 GB) |
Ethernet | 1 Ethernet Port |
Expansions* | Supports 3 Expansion slot |
Environment & Approvals | |
Operating Temperature | 0°C to 50°C |
Storage Temperature | -30°C to 85°C |
Humidity | 10 to 90% (Noncondensing) |
Shock | 25g, 11ms, 6 shocks per axis, Total 18 shocks (X, Y, Z) |
Vibration | 5~150Hz, 3g peak, (X, Y, Z) |
Protection | Front panel-IP66, Rare panel-IP20 |
APPROVALS | CE, UL (Class 1 DIV 2) ,UKCA,REACH& RoHS |
# Note –Applied for FP2070TN-V2 and FP2070TN-E model] Earthing
The optimum method for Earthing electronic equipment is to earth it separately from other high-power systems, to earth more than one unit of electronic equipment with a single-point earth. The Earthing marked terminal (see below) is provided on the unit.

PRODUCT DIMENSIONS
PANEL CUTOUT DIMENSIONS
Panel Cutout Dimensions: 127(H) x 175.00(W)mm
Panel Thickness: Maximum 6mm
Mounting Clamps: 4
Tighten the mounting screws evenly to a torque between
0.4N/m to maintain water and dust resistance.
WARNINGS:
WARNING: DO NOT REMOVE OR REPLACE WHILE BE FREE OF IGNITIBLE CONCENTRATIONS OF FLAMMABLE SUBSTANCES.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only.
WARNING – EXPLOSION HAZARD –Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous.
WARNING – EXPLOSION HAZARD – Substitution of components may impair suitability for Class I, Division 2.
A recommendation for the user to periodically inspect the sealed devices used, for any degradation of properties and replace if degradation is found.
COMMUNICATION
This section provides information regarding communication interfaces supported by this product.
COM1
FP2070Tx-E has one terminal block port (COM1) which support RS232 / RS485 signal levels.
Pin number | Signal |
1 | RX- |
2 | TX- |
3 | RX+ |
4 | TX+ |
5 | GND |
6 | RXD |
7 | TXD |
COM2
FP2070Tx-E has one DB9 female port (COM2) which support RS232 / RS485 signal levels.
Pin No. | Signal |
1 | TX+(RS422/RS485) |
2 | TXD(RS232) |
3 | RXD(RS232) |
4 | RX+(RS422/RS485) |
5 | GND |
6 | NC |
7 | NC |
8 | TX-(RS422/RS485) |
9 | RX-(RS422/RS485) |
Cables
USB Type C Port
- USB Type C, compliant with USB 2.0 specification, self- powered device.
- Connector used: Micro USB Type C Female connector.
USB Host Port
- USB Host, compliant with USB 2.0 specification.
- USB Host can handle only USB memory stick devices and can source current up to 150mA only.
- Connector used: Standard USB Type a Female connector.
Pin number | Signal |
1 | VCC |
2 | D- |
3 | D+ |
4 | GND |
Ethernet Port
- Fully compliant with IEEE 802.3 / 802.3u standards.
- 10 / 100 Mbps support.
- Connector used: Standard shielded RJ-45 female jack with in-built speed and link activity indication LEDs.
Default IP Address: 192.168.0.254
Default Subnet Activity Mask: 255.255.255.0
Pin number | Signal |
1 | TX+ |
2 | TX- |
3 | RX+ |
4 | NC |
5 | NC |
6 | RX- |
7 | NC |
8 | NC |
UL APPROVAL
Capacitance and inductance of the field wiring from the nonincendive equipment to the associated apparatus shall be calculated and must be included in the system calculations as shown in Table 1.
Where the cable capacitance and inductance per foot are not known, the following values shall be used: Ccable = 60 pF/ft., Lcable = 0.2 µH/ft. Wiring method must be in accordance with ANSI/NFPA70
REVISION HISTORY
Rev. | Description | Date |
1.0 | First Draft | 14/08/2020 |
1.1 | Added Website Information | 27/08/2020 |
1.2 | Updated Communication Information | 7/9/2020 |
1.3 | Updated IP rating | 2/6/2021 |
1.4 | Replaced USB type from Micro to Type C | 11/10/2021 |
1.5 | Remove Micro USB Pinout dia | 8/12/2021 |
1.6 | Logo Updated | 20/09/2022 |
1.7 | Specification updated | 9/6/2025 |
RENU Electronics Pvt. Ltd® reserves the right to change or discontinue specifications and features without prior notice.
For More Information, Visit
https://www.renuelectronics.com
Documents / Resources
![]() |
RENU FP2070 SERIES Analog Resistive Touch Screen [pdf] User Guide FP2070 SERIES Analog Resistive Touch Screen, FP2070 SERIES, Analog Resistive Touch Screen, Resistive Touch Screen, Touch Screen |