PW250 Relay Level Converter
Main Features
- M-Bus Level Converter for 250 devices
- Transparent level converting of several interfaces to M-Bus
- Ethernet 10/100BaseT and USB 2.0 with driver for virtual serial port
- 1 x RS232C with terminals (TXD, RXD, GND) and 1 x RS232C with DSUB socket
- 2-wire RS485 interface (not addressable)
- M-Bus Booster with Repeater function for extension of M-Bus networks
- Galvanic isolation of all interfaces from M-Bus
- Intelligent access control of the interfaces by a microcontroller
- Internal power supply with wide range input for worldwide use
- Housing for wall mounting (optional rail mounting kit)
Installation
Mounting
The case of the PW250 can be attached to a wall with four screws. The drill pattern is rectangular (180 mm horizontal, 180 mm vertical). The drillings shall have a diameter of 5 mm. You can alternatively fix a special rail holder to the case to enable the mounting on a rail of the type TS 35 (Accessory: GHZ TSH35-2). The case can be secure closed with the optional cylinder lock (accessory: GHZ Lock).
Connectors in the terminal compartment
PE / PE | Protective conductor (earth) |
L / N | Main power supply 110VAC to 240 VAC, to be connected only by electricians |
M-Bus + – | M-Bus output, wires to the M-Bus meters, 3 pairs of parallel connections |
M-Bus IN Repeater | M-Bus Repeater input for network extension |
RS485 A B | RS485 interface, 2-wire, A = + / B = – |
RS485 Term | Terminator for RS485 interface, jumper placed (default) = 120 Ω |
RS232 RX,TX,GND | RS232C interface, RX = PC receives data, TX = PC transmits data, GND |
Attention: When laying the cables in the terminal compartment, please take care that the light pipes are not blocked by cables after closing the housing cover.
Interfaces at the housing
- Ethernet 10/100MBit RJ45 Ethernet socket for network connection
- RS232 RS232C D-SUB9 socket
- USB Device USB connector of the internal USB-to-RS232 converter (FTDI).
- Cable glands for power supply, M-Bus, RS232C, RS485 and M-Bus IN
LED indicators
There are in total six LEDs in the front part showing the status of the M-Bus. A lighted LED has the following meanings:
Two LEDs in the RJ45 Ethernet socket show the state of the network and the virtual comport. The LEDs have a reduced intensity of 20% of the normal value without a connected network cable. Once a network is connected, the brightness changes to 100%. The most important flash patterns have the following meaning:
You can find all other patterns in the online help of the DS Manager (F1-button) in the chapter “Firmware Manuals / Device Server Application Firmware / Status LED Signals (Red = Green / Green = Yellow).
Description of functions
The PW250 is a transparent Level Converter from several interfaces to M-Bus for up to 250 meters. The device allows external connected controllers such as a building control, a DDC or a PC to read the connected meters by use of an M-Bus software (not in scope of delivery). The PW250 can also be used as a Repeater for extension of M-Bus networks relating to the cable length and number of meters.
Interface multiplexer/switch
An internal microcontroller handles the bus control to just give one interface access to the M-Bus even with multiple connected interfaces. This ensures that systems do not interfere with each other during the communication when two or more systems are connected, for example, a BMS via RS485 and a PC via USB. This automatic switch operates on the principle “first come, first served”, i.e. when an interface sends a signal to the M-Bus, this interface takes control of the M-Bus and has exclusive access to communication. The “ACTIVE” labeled LED indicates the activity status of the internal interface switch. While the LED is lit, one of the six possible interfaces is active. The other interfaces are disabled at this time and cannot access the MBus. The active interface remains enabled for about 3 seconds after the last communication. Another interface can occupy the M-Bus as soon as the LED goes off.
RS232C interfaces
The PW250 has two independent RS232C interfaces, one of them as a 9-pin D-SUB socket in the case front and the other as a 3-pin screw terminal in the terminal compartment. The RS232C pins assignments are: RX = PC transmits to M-Bus, TX = PC receives from M-Bus, GND = Signal ground The pin assignments of the D-SUB socket (female) are designed so that for connection to a PC a simple 9- pin extension cable (male/female with 1: 1 connection) can be used.
Pin 1 | DCD (data carrier detect) | Unused |
Pin 2 | RXD (PC receives data) | M-Bus transmits data to PC |
Pin 3 | TXD (PC transmits data) | PC transmits data to M-Bus |
Pin 4 | DTR (data terminal ready) | Bridged to Pin 6 (DSR) |
Pin 5 | GND (Signal ground) | GND |
Pin 6 | DSR (date set ready) | Bridged to Pin 4 (DTR) |
Pin 7 | RTS (request to send) | Bridged to Pin 8 (CTS) |
Pin 8 | CTS (clear to send) | Bridged to Pin 7 (RTS) |
Pin 9 | RI (ring indicator) | Unused |
RS485 interface
A 2-wire RS485 interface will be connected to the RS485 terminals (A = + and B = -) in the terminal compartment. Please note that this is a transparent interface without addressing on the RS485 bus. The direction control of the half-duplex 2-wire connection is realized that the PW250 is passive in the idle state (receiver on, transmitter off) and becomes on transmitted data from M-Bus meters (receiver off, transmitter on). The level converter remains active on the RS485 for approximately 50ms after the last transmitted space (0-Bit) of the slave. The master software should not start a new request to the connected meters during this period. The RS485 bus is terminated at the factory with a 120Ω resistor. This can be disabled if necessary by removing the jumper “RS485 TERM” on the board in the terminal compartment. The terminating resistor is designed for permanent overvoltage up to a value of 7 VDC on the RS485 bus. If a higher overvoltage protection is required, the jumper should be removed and a proper dimensioned external resistor be connected between terminals A and B.
Repeater interface
The PW250 can be used as a so-called Repeater, as a network extension for existing M-Bus systems, if the maximum number of meters or the maximum cable length has been exceeded for the installation. Up to 250 devices and up to 4km cable (1 x 2 x 0.8 JYSTY) at 2400 baud transmission speed can be connected to a repeater.
The M-Bus line of the existing master or level converter is connected to the terminals labeled with M-Bus IN (Repeater). The polarity does not matter – as usable and standardized for M-Bus slaves. The signal at the M-Bus output of the PW250 is reconditioned to connect a complete M-Bus network. An almost unlimited number of repeaters can be cascaded or connected in parallel due to the automatic measurement of the maximum transmission speed and the recovery of bit times (bit recovery) by the digital repeater. This allows nearly unlimited M-Bus networks.
USB interface
The USB device port of the PW250 is as a USB 2.0 connector type B available on the front of the housing. Please use a USB cable with a type A plug on one end and a type B plug on the other side (not supplied) to connect a PC. You must install the software driver for the virtual COM port before you can use the USB interface. This simulates a serial port that you can use as usual in your M-Bus software. You can find the driver on our CD “Tools & Docs”, on our homepage www.relay.de or directly from FTDI Chip, the manufacturer of the used USB chip: https://ftdichip.com/drivers/vcp-drivers (here you will also find drivers for Linux and Mac OS). Please unpack the ZIP file after download. Install the drivers by clicking on the unzipped file in the File Explorer with the right mouse button and select the menu item “Run as administrator“ (example file name is: CDM212364_Setup.exe).
Now you can connect the PC. The USB driver for the PW250 is installed automatically and generates a new, virtual COM port. The new COM port number of the USB serial port is displayed after the installation is finished (here: COM29). You can look up this number at any time in the Device Manager under ports (USB Serial Port) and – if desired – change it in the advanced settings of the driver. Please select the appropriate comport number in your M-Bus software.
Ethernet interface
The Ethernet interface of the PW250 converts the physical interface Ethernet 10/100BaseT to M-Bus and the TCP / IP protocol to the serial protocol. The Ethernet interface is available in the front panel as an 8-pin RJ45 socket. The PW250 can be integrated into an existing local network and the M-Bus meters can be read from one or more PCs in that network. This requires the so-called “Tibbo Device Server Toolkit” to be installed on that PC. With this software the Ethernet interface is configured in the PW250 and a virtual COM port is set up. This simulated serial interface enables the use of the usual M-Bus software designed for normal serial interfaces. Please perform the following steps of installation:
IT preparations
The IT division of the network containing the PW250 must define the following items:
- Fixed IP address must be identical to the IP range of the reading computer. Only the last number must be different. (e.g. 192.168.1.239)
- You need also the subnet mask and IP address of the gateway if the IP addresses are reassigned by a gateway.
- The converter uses the port 1001 by default for the TCP protocol. This port must not be blocked by any firewall.
You can find your own IP address in your network this way:
Software installation
You can find the driver software on our CD “Tools&Docs”, on our homepage www.relay.de or directly at the manufacturer´s site: https://tibbo.com/support/downloads/tdst.html. Please start depending on your operating system either the 32 bit or 64 bit version of the installation program as an administrator: tdst_5-14-00-x86.exe (32-Bit Windows) or tdst_5-14-00-x64.exe (64-Bit Windows) TDST = Tibbo Device Server Toolkit, 5-14-00 = Version 5.14.00 dated August 2021)
After a reboot of the PC the installation of the drivers and software tools is completed
Setup of the device server
Please start the Tibbo – DS Manager (Start – Programs – Tibbo – Tibbo Device Server Toolkit –
Tibbo DS Manager
The DS Manager (DS = Device Server) shows all by broadcast detectable device servers in the sheet „AutoDiscovery“. Device servers which are not in the same IP address range will not be found and must be manually added into the sheet “Address Book” (button “Add”). Please select the device which you want to configure and click on the button “Settings”. Then you see the settings of the device which you shall change according to the following pictures. You can get help for the DS Manager with F1 key.
Recommended settings:
Setup of the virtual port
The next step is the setup of a virtual, serial port in your PC. You don´t need the virtual port if the used software offers a TCP/IP port instead of serial ports. In this case you must correctly program all settings of the serial interface like baudrate, parity and data bits. You also don´t need a virtual port in the bridge mode (two device servers connected together, i.e. one TCP001 (serial device server) to the PW250. Please start the Tibbo – DS Manager (Start – Programs – Tibbo – Tibbo Device Server Toolkit – Tibbo VSP Manager.
Please do the following settings:
Then you can program the values for the serial communication after startup in the sheet “Default Serial Settings” (baudrate, data bits, parity, flow control). A click at „OK“ generates the virtual port and then it can be used in your M-Bus software. Please select the respective port (VSP name) in your software as the communication interface. Now the installation is completed. You can change the settings of the device and the COM port using the DS manager respectively the VSP manager at any time. You can also change the settings of the device server and check its routing state after first setup using a web browser connected to the assigned IP address. The required password for the login is empty on delivery.
Technical data
General data
Operating voltage | 110 .. 240 VAC, 47 .. 63 Hz |
Power consumption | max. 100W |
Operating temperature range | 0 .. 45°C |
M-Bus voltage | 42 V ( Mark), 28V (Space) |
M-Bus basic current | max. 375 mA |
Overcurrent threshold | > 500 mA |
Internal bus resistance | 8 Ohm |
Communication speeds | 300 .. 38400 Baud |
Bit threshold | typ. 7,0 mA |
Collision threshold | typ. 48 mA |
Maximum cable length for
recommended cable type JYSTY 1 x 2 x 0,8 mm |
Total (all wires): 1km (9600 baud), 4km (2400 baud), 10km (300 baud)
Max. distance to slave (250 slaves at the end of the cable): 350 m Max. distance to slave (250 slaves equally distributed): 900 m |
Galvanic isolation | All interface are isolated from M-Bus and power supply. The Repeater input is additionally isolated from the other interfaces. |
Overcurrent threshold | > 500 mA |
Internal bus resistance | 8 Ohm |
Communication speeds | 300 .. 38400 Baud |
Bit threshold | typ. 7,0 mA |
Collision threshold | typ. 48 mA |
Maximum cable length for
recommended cable type JYSTY 1 x 2 x 0,8 mm |
Total (all wires): 1km (9600 baud), 4km (2400 baud), 10km (300 baud)
Max. distance to slave (250 slaves at the end of the cable): 350 m Max. distance to slave (250 slaves equally distributed): 900 m |
Galvanic isolation | All interface are isolated from M-Bus and power supply. The Repeater input is additionally isolated from the other interfaces. |
Housing | Light-grey ABS plastic, protective class IP52 H x W x D: 229 x 204 x 76 mm
Mounting on a rail or wall, optional cylinder lock |
LED indicators | Power, communication master, slave, warning, short circuit M-Bus, M-Bus activity |
Interfaces | 10/100 Mbit Ethernet, USB device, RS232C (SUB-D9), RS232C (terminals), RS485, Repeater (M-Bus IN) |
Terminals | 3 pairs screw terminals for M-Bus, 3-pin screw terminal for RS232C, each 1 pair screw terminals for RS485 and Repeater, 4-pin screw terminal for power supply |
Interface data
RS232C | Driver load | Current max. 5mA, resistive: min. 3kΩ, capacity: max. 2,5 nF |
Voltage transmit (at 3kΩ) | Mark: +5V ≤ UT ≤ +15V
Space: -15V ≤ UT ≤ -5V |
|
Voltage receive | Mark: +2,5V ≤ UR ≤ +15V
Space: -15V ≤ UR ≤ -2,5V |
|
RS485 | Driver load | Current max. 250 mA, resistance min. 54Ω |
Signal voltage TX | Space (0): +1.5V £ Ut £ +5.0V Mark (1): -5.0V £ Ut £ -1.5V | |
Addressing | Not possible (transparent) | |
Repeater | Current M-Bus IN | Basic current < 1,5 mA (1 Unit Load), TX current typ. 15mA |
Capacity | Max. 250 pF | |
Galvanic isolation | > 2,5 kV to all interfaces, M-Bus and power supply | |
USB | Type | USB 2.0 device, socket type B |
USB IC | FTDI Chip: FT232R, Vendor ID = 0403, Product ID = 6001 | |
Power supply | Bus powered, Low Power (max. 90mA) | |
Ethernet | Network interface | 10/100BaseT (RJ45), auto-MDIX, with 2 LEDs |
Protocols / adressing | TCP and UDP / static IP or dynamic IP (DHCP) |
Ordering information
Article number | Description |
PW250 | M-Bus Level Converter and Repeater for 250 slaves |
KA003 | Power cable 2m, with German plug according to CEE 7/4, grey |
KA USB AB | USB cable A to B plug/plug, length = 1m, grey |
KA PATCH.5E RJ45 1M | Network patch cable CAT5E FTP, Length = 1m, grey |
GHZ TSH35-2 | Rail mounting set TH35 incl. screws |
GHZ Lock | Cylinder lock for front lid of PW250 housing incl. 2 keys |
FAQ
- Q: What is the maximum number of devices the PW250 can support?
- A: The PW250 can support up to 250 devices.
- Q: Can the PW250 function as a repeater for extending M-Bus networks?
- A: Yes, the PW250 can be used as a repeater for extension of M-Bus networks based on cable length and number of meters.
Documents / Resources
![]() |
Relay PW250 Relay Level Converter [pdf] User Manual PW250 Relay Level Converter, PW250, Relay Level Converter, Level Converter |