Rapidline logoHalo Static Single Sided Fixed
Height Workstation Frame

Instruction ManualRapidline Static Single Sided Fixed Height Workstation Frame

Component parts

Rapidline Static Single Sided Fixed Height Workstation Frame - Component parts

NO. Component Name PCS
1 Table feet 2
2 Column( right) 1
3 Bolt: M6x12 5
4 Screw: ST4x20 22
5 Side brackets 2
6 Rubber pad 14
7 Top frame-1 1
8 Bolt: M6x10 3
9 Centre bracket 1
10 Center rails 2
11 Top frame-2 1
12 Column( left) 1
13 Allen Wrench(4mm) 1
14 Allen Wrench(5mm) 1
15 Cable Tie 5

Assembly Instructions

Step 1
Loosen the pre-installed bolts and adjust the length of the top frame to match the size of the table top.

Rapidline Static Single Sided Fixed Height Workstation Frame - Assembly Instructions 1

Step 2
Insert the Column to the top frame, fix the lifting column with 4pcs of screws M6x12 like.

Rapidline Static Single Sided Fixed Height Workstation Frame - Assembly Instructions 2

Step 3
Place the table feet on the Column and rotate it to align, then tighten the pre-installed bolt.

Rapidline Static Single Sided Fixed Height Workstation Frame - Assembly Instructions 3

Step 4
Place the side bracket on the top frame and tighten the bolts.

Rapidline Static Single Sided Fixed Height Workstation Frame - Assembly Instructions 4

Step 5
Mount the tabletop and fix it with 14 pcs screws ST4x20;
Fix the centre bracket with 2 pcs of screws M6x10
Tighten the pre-installed bolts on the top frame

Rapidline Static Single Sided Fixed Height Workstation Frame - Assembly Instructions 5

Cable tray installation

Step 1
– Fix the cable tray (B2-SSCT ) to the cable tray arms (HP-SSARM) with 8 pcs M6x10 screws.

Rapidline Static Single Sided Fixed Height Workstation Frame - Cable tray installation 1

Step 2
– Install the U brackets to the desk frame with 4 pcs M8x10 screws.
– Mount the cable tray to the desk frame and fix it with 6 pcs M6x10 screws

Rapidline Static Single Sided Fixed Height Workstation Frame - Cable tray installation 2

Screen panel installation ( Shush30 Privacy Screen )

Step 1
– Insert the tapped plates to the screen panel ( plates can be found in the B2-SBRAC carton )

Rapidline Static Single Sided Fixed Height Workstation Frame - Screen panel installation 1

Step 2
– Install the screen brackets (B2-SBRAC) to the Shush30 Extrusion with 8 pcs M5x6 screws.

Rapidline Static Single Sided Fixed Height Workstation Frame - Screen panel installation 2

Step 3
– Fix the screen brackets (B2-SBRAC) to the desk frame with 10 pcs M6x10 screws.

Rapidline Static Single Sided Fixed Height Workstation Frame - Screen panel installation 3

EPS (900mm H Eco Panel) Screen panel installation

Step 1
– Install the screen brackets (B2-SBRAC) on the cable tray arm (HP-SSARM)with 10 PCS M6x10 Screws. The direction as the photos display.

Rapidline Static Single Sided Fixed Height Workstation Frame - Screen panel installation 4

Step 2
– Place the EPS panel on the screen brackets
Using a 6mm drill bit ( not included ), drill out holes in the Eco Panel Screen in line with the back-to-back screen bracket holes ( Note: Carbide Drill Bits Work Best For PET panel )
– Place 8 x Double Ended Bolts M5* 32mm – 6mm through the screen bracket ( B2-SBRAC ) holes and the holes you have created in the Eco Panel Screen. Tighten the double-ended bolt with the Allen key.

Rapidline Static Single Sided Fixed Height Workstation Frame - Screen panel installation 5