QK-CE2204UNI Swing Gate Control Board
“
Product Specifications
- Model: V25 HB2125
- Origin: Made in Italy
- Control Board: QK-CE2204UNI 230V
- Power Supply: 230 VAC 50/60 HZ +- 10%
- Operating Modes: Sliding, Swing, Dual Sliding
Product Usage Instructions
Gate Configuration
The control board has three operating modes for different gate
types: Sliding, Swing, or Dual Sliding. When powered up, the
display shows the operating mode set followed by the firmware
version.
Changing Control Board Mode
To change the control board mode:
- Hold down Button A or B until the display shows “DT”.
- Hold down Button C or D until the display blinks to show the
operating mode you are setting. - When the display stops blinking, the configuration has been
set.
Checking Motor Direction
To check if the motors turn in the right direction:
- Ensure the phases cables of the motor/s are correctly
connected. - If one or both motors close instead of open, swap the
connections. - DIR2 = CLOSE is the default setting for swing gate
operation.
Frequently Asked Questions (FAQ)
Q: Where can I find the complete user manual?
A: The complete user manual is available for download in the
reserved area of our website quikoitaly.com. Please refer to it for
more detailed information.
“`
® QK-CE2204UNI 230V CONTROL BOARD QUICK
MADE IN ITALY
V25 HB2125
SWING GATE CONFIGURATION GUIDE
TERMINAL BLOCK CONNECTION
GO
START
5t
STOP
E1
+24V
E2
+24V
1 2 3 4 5 6 7 8 9 101112
1 2 3 4 5 6 7 8 9 101112
E1 = GO
PE
PEDESTRIAN
E7 +24V
1 2 3 4 5 6 7 8 9 101112
E2 = 5t
FLASHING LAMP
1 2 3 4 5 6 7 8 9 101~11~2
QK-CE2204UNI 230V CONTROL BOARD
V25 HB2125
SWING GATE CONFIGURATION
The control board has three opera ng modes for different kinds of gate: SLIDING, SWING, or DUAL SLIDING. When powered up the display shows the opera ng mode set followed by the firmware version. The opera ng mode can also be viewed by selec ng DT parameter.
A
x5 SLIDING xb SWING
B C
xx DOUBLE SLIDING D
UP DOWN
YES NO
QUICK
GUIDE
®
MADE IN ITALY
BLACK
SIGNAL SCREEN
RED
E7 = PE
24 VDC OUTPUT
+24V -24V
1 2 3 4 5 6 7 8 9 101112
TA OPENING PHOTOCELLS
E4
+24V GND
1 2 3 4 5 6 7 8 9 101112
TA
RX
TX
E4 = TA
NC +
+
A MOTOR
First motor to open, last motor to close.
1314 15
COM
DIR1
DIR2
A
13
15
If one or both motors closes instead, swap
L8 = NO DIR1 = OPEN
24 VAC 20 W
230 VAC POWER SUPPLY
230 VAC 50/60 HZ +- 10%
19 G120
G2
on PCB
N
L
TD CLOSING PHOTOCELLS
E3
+24V GND
1 2 3 4 5 6 7 8 9 101112
Td
RX
TX
E3 = TD
NC +
+
B MOTOR
1617 18
COM
DIR1
DIR2
B
16
18
the phases cables of the motor/s that was closing.
DIR2 = CLOSE swing gate default
A 88
B
24 VAC
230 VAC
G2
C+ – D
E1 E2 E3 E4 E5 E6 E7 +24
+24 TEST – 24V
~~
FUSE 52A30V
230VAC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A MOTOR B MOTOR 19 G1 20
NL
HOW TO CHANGE CONTROL BOARD MODE
Hold A er
down or keep pressing about one second, the
BUTTON A or B un l display shows display shows the current opening
DT. mode:
H5
HB
HH
Hold down BUTTON C or D of the control board. The display blinks showing the opera ng
mode you are se ng.
When the display stops blinking, the configura on has been set.
CHECKING IF THE MOTORS TURN IN THE RIGHT DIRECTION
Once all the connec ons have been done and the system is ready to start, before se ng the system it is important to check that the motors turn in the right direc on. To do that: 1 Power supply the control board and check that the display shows Hb 21 25 2 Remove electricity. 3 Unlock both motors and manually put the leafs in the middle. 4 Give electricity. 5 Give a first start impulse to the system with remote control or push – bu on. 6 Make sure that both motors open. 7 If one or both motors closes instead, swap the phases cables of the motor/s that was closing. 8 Once you have swapped motor/s phases cables, repeat the procedure above and make sure that now both motors open at first start signal a er giving electricity. 9 The system is now ready for setup.
QK-CE2204UNI ®
MADE IN ITALY
V25 HB2125
XB 230V CONTROL BOARD SWING GATE CONFIGURATION
QUICK GUIDE
®
MADE IN ITALY
MENU
xb default
A1 14
A2 7.0
A3 0.8
A4 06
A5 06
MOTOR A SETTING
Standard Working me Slowdown working me Start up me Displacement me on closure Standard force
IMPORTANT NOTICE: when you see this symbol please refer to the complete user manual for more details. The complete user manual is available for download in the reserved area of our website quikoitaly.com
MENU
xb default
r0
r1
A6 08 A7 no A8 No aa no
Slowdown force
C D from 00 to 99 to no Standard oblstacle detec on threshold. During opening, for standard working me, the display shows motor A stress. C D from 00 to 99 to no Slowdown oblstacle detec on threshold. During opening, for slowdown working me, the display shows motor A stress.
Final release: motor A open for “0. aa” sec at the end of closing to be er meet european safety standards. It works with obstacle detec on only.
MENU
xb default
f0 10
f1 07
f2 0.0
f3 0.0
f4 No
f5 01
FUNCTIONS
Automa c closure me. To disable hold down C bu on un l display shows 5t Pedestrian working me Kick-back func on during closing. It can be useful when an electric-lock is installed. Pre-blinking me
Kick-back func on during opening. It can be useful when an electric-lock is installed. Logic: STANDARD 01 COMMUNITY 02 STEP-BY-STEP 03
R2 R3 R4
MENU
xb default
b1 14
b2 7.0
b3 0.8
b4 03
b5 06
b6 08
b7 no
b8 No
MOTOR B SETTING
Standard Working me
Slowdown working me
Start up me
Displacement me on closure
Standard force
Slowdown force C D from 00 to 99 to no Standard oblstacle detec on threshold. During opening, for standard working me, the display shows motor B stress. C D from 00 to 99 to no Slowdown oblstacle detec on threshold. During opening, for slowdown working me, the display shows motor B stress.
f7 5.0 f8 No l0 no
l1 no l5 no l6
l7 00 l8 no
t1 no t2 51 o1 07
o2 13
Fast closure delay
Safety devices as sliding
Electric lock me from no (disabled) to 99 seconds. Cold winter func on It is useful in countries where the winter is extremely cold. Assistance request from cycle counter
Work cycles counter Flashing lamp opera ng mode Swap motors direc on
0 = FLASHING LAMP 1 = FIXED LAMP
Photocells test
Motors thermal protec on test 51 = ENABLE
Output 1 func on Output 2 func on
QK-RELAY *op onal
These func ons are useful when output expansions are used.
MENU
xb default
WORKING TIME PROGRAMMING
P2
2 motors working me programming
P6
Obstacle detec on threshold programming
MENU
xb default
CONTROL BOARD MODE
MENU
xb default
RB 01
RADIO SELECTION
Internal radio 01 External radio module 02
ON PCB QK-MODRAL4 *op onal
MENU
xb default
t=
r=
e=
LOGS
Errors log
Radio log
Input log
R5
MENU
xb default
r6 PO
r7 PC
r8 el
MENU
xb default
e1 go
e2 no
e3 no
e4 no
e5 op
e6 cL
e7 pe
D0 DT
Restore factory se ng selected by dt
CD
Change control board mode and set its factory se ng.
MENU
TA
SAFETY DEVICE DISPLAY REPORT Opening photocells
MENU
GO PE FG
START & SERVICE COMMAND DISPLAY REPORT Start / Pedestrian / Fast Closure
MENU
9A 9b 7A 7b 1t
TEST & GATE FUNCTION DISPLAY REPORT Motor A/B is in thermal protec on Motor A/B has detected an obstacle Photocells test error
TD TC Fx OO CC
Closing photocells mode 2/1 Opening + Closing photocells Opening / closing 8K2 Sa y Edge
OP Cl Po PC el do
Open only / Close only Open / Close Dead man Eletric lock Remote key dummy func on
5l
Assistance request func on
5T
Stop
Eo
Terminal block dummy func on
®
REMOTE KEY CONFIGURATIONS
Erase a remote control key: hold down C bu on on the selected code un l display turns off.
Save a remote control key as START: hold down a remote key. When the display shows __._ push down C bu on.
Save a remote control key as STOP: hold down a remote key. When the display shows __._ push down C bu on.
Save a remote control key as PEDESTRIAN START: hold down a remote key. When the display shows __._ push down C bu on.
Save a remote control key as FAST CLOSURE: hold down a remote key. When the display shows __._ push down C bu on.
Erase all remotes control keys: hold down C bu on un l display stops flashing 51
PROGRAMMABLE FUNCTIONS
The func on you can select is one of the following: op Open Only, Cl Close Only, PO Dead Man Open, PC Dead Man Close, el Electric lock, dO dummy output, rt radio range.
TERMINAL BLOCKS FUNCTIONS
1
Terminal block input 1
2
Terminal block input 2
3
Terminal block input 3
4
Terminal block input 4
5
Terminal block input 5
6
Terminal block input 6
7
Terminal block input 7
MENU
FC LC fa la ua xa uC xC ab 1x 2x 3x
LIMIT SWITCHES DISPLAY REPORT Motor A closing limit switch NC / NO Motor A opening limit switch NC / NO Motor B closing limit switch NC / NO Motor B opening limit switch NC / NO Motor A+B limit switches Motor A limit switches error Motor B limit switches error Motor A+B limit switches error
MADE IN ITALY
Documents / Resources
![]() |
QUIKO QK-CE2204UNI Swing Gate Control Board [pdf] Instruction Manual QK-CE2204UNI, V25 HB2125, QK-CE2204UNI Swing Gate Control Board, QK-CE2204UNI, Swing Gate Control Board, Gate Control Board, Control Board |