Instruction Manual for QUIKO models including: QK-CE2204UNI, V25 HB2125, QK-CE2204UNI Swing Gate Control Board, QK-CE2204UNI, Swing Gate Control Board, Gate Control Board, Control Board
made in italy 230v control board swing gate configuration l8 = no dir1 = open dir2 = close swing gate default b motor 13 15 16 18 terminal block connection nc 123456789101112 24v gnd rx tx td e3 e3 = td 123456789101112 24v gnd rx e4 tx nc ta e4 = ta ta opening photocells td closing photocells 123456789101112 e7 24v e7 = pe
7 feb 2025 — Hold down or keep pressing BUTTON A or B un l display shows . DT. ○ After about one second, the display shows the current opening mode: H5 HB HH.
Hold down or keep pressing BUTTON A or B un l display shows . DT. ○ After about one second, the display shows the current opening mode: H5 HB HH.
File Info : application/pdf, 2 Pages, 3.46MB
DocumentDocument® QK-CE2204UNI 230V CONTROL BOARD QUICK MADE IN ITALY V25 HB2125 SWING GATE CONFIGURATION GUIDE TERMINAL BLOCK CONNECTION GO START 5t STOP E1 +24V E2 +24V 1 2 3 4 5 6 7 8 9 101112 1 2 3 4 5 6 7 8 9 101112 E1 = GO PE PEDESTRIAN E7 +24V 1 2 3 4 5 6 7 8 9 101112 E2 = 5t FLASHING LAMP 1 2 3 4 5 6 7 8 9 101~11~2 QK-CE2204UNI 230V CONTROL BOARD V25 HB2125 SWING GATE CONFIGURATION The control board has three opera ng modes for different kinds of gate: SLIDING, SWING, or DUAL SLIDING. When powered up the display shows the opera ng mode set followed by the firmware version. The opera ng mode can also be viewed by selec ng DT parameter. A x5 SLIDING xb SWING B C xx DOUBLE SLIDING D UP DOWN YES NO QUICK GUIDE ® MADE IN ITALY BLACK SIGNAL SCREEN RED E7 = PE 24 VDC OUTPUT +24V -24V 1 2 3 4 5 6 7 8 9 101112 TA OPENING PHOTOCELLS E4 +24V GND 1 2 3 4 5 6 7 8 9 101112 TA RX TX E4 = TA NC + + A MOTOR First motor to open, last motor to close. 1314 15 COM DIR1 DIR2 A 13 15 If one or both motors closes instead, swap L8 = NO DIR1 = OPEN 24 VAC 20 W 230 VAC POWER SUPPLY 230 VAC 50/60 HZ +- 10% 19 G120 G2 on PCB N L TD CLOSING PHOTOCELLS E3 +24V GND 1 2 3 4 5 6 7 8 9 101112 Td RX TX E3 = TD NC + + B MOTOR 1617 18 COM DIR1 DIR2 B 16 18 the phases cables of the motor/s that was closing. DIR2 = CLOSE swing gate default A 88 B 24 VAC 230 VAC G2 C+ - D E1 E2 E3 E4 E5 E6 E7 +24 +24 TEST - 24V ~~ FUSE 52A30V 230VAC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 A MOTOR B MOTOR 19 G1 20 NL HOW TO CHANGE CONTROL BOARD MODE Hold A er down or keep pressing about one second, the BUTTON A or B un l display shows display shows the current opening DT. mode: H5 HB HH Hold down BUTTON C or D of the control board. The display blinks showing the opera ng mode you are se ng. When the display stops blinking, the configura on has been set. CHECKING IF THE MOTORS TURN IN THE RIGHT DIRECTION Once all the connec ons have been done and the system is ready to start, before se ng the system it is important to check that the motors turn in the right direc on. To do that: 1 Power supply the control board and check that the display shows Hb 21 25 2 Remove electricity. 3 Unlock both motors and manually put the leafs in the middle. 4 Give electricity. 5 Give a first start impulse to the system with remote control or push - bu on. 6 Make sure that both motors open. 7 If one or both motors closes instead, swap the phases cables of the motor/s that was closing. 8 Once you have swapped motor/s phases cables, repeat the procedure above and make sure that now both motors open at first start signal a er giving electricity. 9 The system is now ready for setup. QK-CE2204UNI ® MADE IN ITALY V25 HB2125 XB 230V CONTROL BOARD SWING GATE CONFIGURATION QUICK GUIDE ® MADE IN ITALY MENU xb default A1 14 A2 7.0 A3 0.8 A4 06 A5 06 MOTOR A SETTING Standard Working me Slowdown working me Start up me Displacement me on closure Standard force IMPORTANT NOTICE: when you see this symbol please refer to the complete user manual for more details. The complete user manual is available for download in the reserved area of our website quikoitaly.com MENU xb default r0 r1 A6 08 A7 no A8 No aa no Slowdown force C D from 00 to 99 to no Standard oblstacle detec on threshold. During opening, for standard working me, the display shows motor A stress. C D from 00 to 99 to no Slowdown oblstacle detec on threshold. During opening, for slowdown working me, the display shows motor A stress. Final release: motor A open for "0. aa" sec at the end of closing to be er meet european safety standards. It works with obstacle detec on only. MENU xb default f0 10 f1 07 f2 0.0 f3 0.0 f4 No f5 01 FUNCTIONS Automa c closure me. To disable hold down C bu on un l display shows 5t Pedestrian working me Kick-back func on during closing. It can be useful when an electric-lock is installed. Pre-blinking me Kick-back func on during opening. It can be useful when an electric-lock is installed. Logic: STANDARD 01 COMMUNITY 02 STEP-BY-STEP 03 R2 R3 R4 MENU xb default b1 14 b2 7.0 b3 0.8 b4 03 b5 06 b6 08 b7 no b8 No MOTOR B SETTING Standard Working me Slowdown working me Start up me Displacement me on closure Standard force Slowdown force C D from 00 to 99 to no Standard oblstacle detec on threshold. During opening, for standard working me, the display shows motor B stress. C D from 00 to 99 to no Slowdown oblstacle detec on threshold. During opening, for slowdown working me, the display shows motor B stress. f7 5.0 f8 No l0 no l1 no l5 no l6 l7 00 l8 no t1 no t2 51 o1 07 o2 13 Fast closure delay Safety devices as sliding Electric lock me from no (disabled) to 99 seconds. Cold winter func on It is useful in countries where the winter is extremely cold. Assistance request from cycle counter Work cycles counter Flashing lamp opera ng mode Swap motors direc on 0 = FLASHING LAMP 1 = FIXED LAMP Photocells test Motors thermal protec on test 51 = ENABLE Output 1 func on Output 2 func on QK-RELAY *op onal These func ons are useful when output expansions are used. MENU xb default WORKING TIME PROGRAMMING P2 2 motors working me programming P6 Obstacle detec on threshold programming MENU xb default CONTROL BOARD MODE MENU xb default RB 01 RADIO SELECTION Internal radio 01 External radio module 02 ON PCB QK-MODRAL4 *op onal MENU xb default t= r= e= LOGS Errors log Radio log Input log R5 MENU xb default r6 PO r7 PC r8 el MENU xb default e1 go e2 no e3 no e4 no e5 op e6 cL e7 pe D0 DT Restore factory se ng selected by dt CD Change control board mode and set its factory se ng. MENU TA SAFETY DEVICE DISPLAY REPORT Opening photocells MENU GO PE FG START & SERVICE COMMAND DISPLAY REPORT Start / Pedestrian / Fast Closure MENU 9A 9b 7A 7b 1t TEST & GATE FUNCTION DISPLAY REPORT Motor A/B is in thermal protec on Motor A/B has detected an obstacle Photocells test error TD TC Fx OO CC Closing photocells mode 2/1 Opening + Closing photocells Opening / closing 8K2 Sa y Edge OP Cl Po PC el do Open only / Close only Open / Close Dead man Eletric lock Remote key dummy func on 5l Assistance request func on 5T Stop Eo Terminal block dummy func on ® REMOTE KEY CONFIGURATIONS Erase a remote control key: hold down C bu on on the selected code un l display turns off. Save a remote control key as START: hold down a remote key. When the display shows __._ push down C bu on. Save a remote control key as STOP: hold down a remote key. When the display shows __._ push down C bu on. Save a remote control key as PEDESTRIAN START: hold down a remote key. When the display shows __._ push down C bu on. Save a remote control key as FAST CLOSURE: hold down a remote key. When the display shows __._ push down C bu on. Erase all remotes control keys: hold down C bu on un l display stops flashing 51 PROGRAMMABLE FUNCTIONS The func on you can select is one of the following: op Open Only, Cl Close Only, PO Dead Man Open, PC Dead Man Close, el Electric lock, dO dummy output, rt radio range. TERMINAL BLOCKS FUNCTIONS 1 Terminal block input 1 2 Terminal block input 2 3 Terminal block input 3 4 Terminal block input 4 5 Terminal block input 5 6 Terminal block input 6 7 Terminal block input 7 MENU FC LC fa la ua xa uC xC ab 1x 2x 3x LIMIT SWITCHES DISPLAY REPORT Motor A closing limit switch NC / NO Motor A opening limit switch NC / NO Motor B closing limit switch NC / NO Motor B opening limit switch NC / NO Motor A+B limit switches Motor A limit switches error Motor B limit switches error Motor A+B limit switches error MADE IN ITALY