Introduction
QSFPTEK S7600-24X2C L3+ aggregation switch is designed with 24x 10G SFP+ ports and 2x 40/100G QSFP28 uplinks. Each QSFP28 port can be split into 4x 10G ports or 4x 25G ports, providing converged 10G, 25G, 40G, and 100G fiber links. This 24-port switch delivers an 880 Gbps switching capacity and 540 Mpps forwarding rate to meet high-performance aggregation layer requirements. The 10GbE network switch is equipped with 2 hot-swap AC power supplies (1+1 redundancy) and 3 built-in smart fans (2+1 redundancy), providing hardware redundancy for enhanced reliability. As a layer 3+ managed switch, it supports full layer 3 features (static routing, RIP, OSPF, BGP, etc.) and advanced data center features such as MLAG for high-reliability and VXLAN, NVGRE, GENEVE tunnel technology for virtual networking. S7600 series aggregation switches support remote direct memory access (RDMA), which over other network APIs for lower latency, CPU load, and higher bandwidth. This 24-port 10Gb switch caters to the Ethernet aggregation platform to HCI (hyper-converged infrastructure), cloud networking, data center, and enterprise applications.
Accessories
Hardware Overview
Front Panel Ports
Ports | Description |
SFP+ | Hot-swappable SFP+ ports for 1/10G connection |
QSFP28 | QSFP28 ports for 40G/100G connection |
CON | An RJ45 console port for serial management |
ETH | An RJ-45 Ethernet management port |
USB | A USB management port for software and configuration backup and offline software upgrade |
Front Panel LEDs
LEDS | Status | Description | |
ID | Blue | On | ID indication function enable |
Off | ID indication function disable | ||
SYS | Green | On | The system is normal running |
Amber | On | The system occur alarm or error | |
– | Off | No power or system is not run or abnormality | |
ETH | Green | On | Port link. |
Blinking | Port is receiving or transmitting packets. | ||
Off | Port not link. | ||
SFP+ | Green | On | 10G port link. |
(Port 1-24) | Blinking | 10G packets receiving or transmitting. | |
Amber | On | 1G port link. | |
Blinking | 1G packets receiving or transmitting. | ||
– | Off | Port not link | |
QSFP28 (Port 25-26) | Green | On | 100G/40G port link. |
Blinking | 100G/40G packets receiving or transmitting. | ||
Amber | On | 100G/40G port link. | |
Blinking | 100G/40G packets receiving or transmitting. | ||
– | Off | Port not link |
Back Panel
Installation Requirements
Tools Preparation
- Flathead screwdrivers
- Phillips screwdrivers
- ESD-preventive wrist strap
Temperature/Humidity Requirements
Temperature | Humidity |
0~45°C | 10%~95% |
Cleanliness Requirements
Substance | Unit | Concentration limit |
DUST | Particle/m3 | ≤ 3 X 104 (No visible dust on the tabletop for three days) |
SO2 | mg/m3 | 0.2 |
H2S | mg/m3 | 0.006 |
NH3 | mg/m3 | 0.05 |
Cl2 | mg/m3 | 0.01 |
Note: The dust particle size is ≥ 5 μm |
Mounting the Switch
Connecting the Power
Plug the AC power cord to the switch power port on the back rear.
- Connect the other end of the power cord to an AC power source equipment.
Connecting the SFP+ Ports
- Insert the SFP+ module into the SFP+ port.
- Plug a fiber patch cable into the SFP+ transceiver.
- Connect the other end of the fiber to the device that you want to realize data communication.
Connecting the QSFP28 Port
- Insert the QSFP28 module into the QSFP28 port.
- Plug a fiber patch cable to the QSFP28 transceiver.
- Connect the other end of the fiber to the device that you want to realize data communication.
Connecting the Management Ports
Connecting the Console Port
- Prepare a console cable.
- Insert the RJ45 connector of the console cable into the console port on the switch.
- Connect the D89 female connector on the other end of the console cable to the serial port on the computer host.
Connecting the ETH Port
- Prepare a standard RJ45 Ethernet patch cable.
- Insert one end of the RJ45 Ethernet patch cable into the computer RJ45 port.
- Connect the RJ45 connector on the other end of the patch cable to the ETH port on the switch.
Connecting the USB Port
- Prepare a Universal Serial Bus (USB) flash disk.
- Insert the USB to the switch USB port.
Configuring the Switch
Configuring the Switch Using the Web-based Interface
- Step 1: Connect your computer to the switch using an Ethernet cable and open a web browser.
- Step 2: Set the IP address of the computer to 192.168.1.x (where “x” is any number from 2 to 254) and the subnet mask to 255.255.255.0.
- Step 3: Open a web browser and type http://192.168.1.1 in the address bar. Enter the default username and password (admin/admin).
- Step 4: Click sign-in to access the web-based configuration page.
Configuring the Switch Using the Console Port
- Step 1: Use the console cable to directly connect the switch console port to your computer.
- Step 2: Launch the terminal simulation software such as Hyper Terminal on the computer.
- Step 3: Configure the parameters of the terminal emulation software as follows: 115200 bits per second, 8 data bits, no parity, 1 stop bit, and no flow control.
- Step 4: Enter the default username and password (admin/admin).
Troubleshooting
Loading Failure Processing
After loading fails, the system will keep running in the original version. At this time, users should refer to the following steps to re-check:
- if physical port connections are good first. If some ports are not connected, then re-connect them to ensure that physical connections are correct, and begin re-loading.
- If physical connections are correct, then check the loading process information displayed on the super terminal to verify if there are input errors. If there are input errors, correct them and re-load. For example, when using TFTP protocol, we enter incorrect IP addresses of the Server and Switch, name of loading software, do not specify the correct working path of the correct TFTP server, and so on.
- if physical connections are good, and there are no input errors in the loading process but the loading fails finally, please contact agents for help.
User Password Lost
If the system password is lost or forgotten, the following method can be used to reset the password:
- Enter uBoot operation mode; see Chapter 5 for how to enter;
- Input the boot_flash_nopass command to start the system in uBoot mode;
Note: After using the boot_flash_nopass command, the system will clear up the startup-config files; before starting this operation, the startup-config files will be stored in flash:/startup-config.conf.old file.
Power System Troubleshooting
The switch can judge if its power system is faulty according to the PWR indicator on the front panel: when the power system works normally, the PWR indicator shall always keep lighting; when the PWR indicator is off, please check if:
- The power line of the switch is connected correctly.
- The EPS of the switch matches the power required by the switch.
Configuration System Troubleshooting
After the switch is powered on, if the system is normal, the startup information will be displayed on the configuration terminal; If no display information on the configuration terminal appears, maybe the configuration system is faulty, please check if:
- The power is normal.
- The cable of the configuration port (Console) is properly connected.
If no problems have been found after the above checks, it is possible that the configuration cable is faulty or the parameter setting of the terminal (such as a super terminal) is incorrect, please check accordingly. - Troubleshooting for the terminal displaying hashes:
If the configuration terminal displays hashes, probably the parameter setting of the terminal (such as a super terminal) is incorrect Please confirm the parameter setting of the terminal (such as HyperTerminal): baud rate: 115200, data bit: 8, parity: no, stop bit: 1, flow control: NA, selecting terminal emulation: VT100.
Support and Other Resources
- Contact us https://www.qsfptek.com/company/contact-us.html
- Customer Success https://www.qsfptek.com/resources/customer-success-stories
- Email support@qsfptek.com
Product Warranty
S7600 series switches are backed by a 5-year limited warranty supported by QSFPTEK. You are eligible to apply for a return within 14 days and exchange within 90 days of receiving them.
For more details about applying qualifications, please live chat or email sales@qsfptek.com for support.
- 5 Year Warranty
- 14-day Return Window
- www.qsfptek.com
FAQ
What should I do if the LEDs indicate an error?
If the LEDs indicate an error, check the system status, power connections, and port linkages for abnormalities. Refer to the user manual for troubleshooting steps.
Documents / Resources
![]() |
QSFPTEK S7600-24X2C L3 Plus Aggregation Switch [pdf] User Guide S7600-24X2C, S7600-24X2C L3 Plus Aggregation Switch, L3 Plus Aggregation Switch, Aggregation Switch, Switch |