K2202-CX-EGB-16-WIFI Automatic Sliding Gate Opener
“
Specifications:
- Power supply: AC 220V
- Maximum load: 1000KGS
- Rated power: 80W
- Rated speed: 1400RPM
- Open/close speed: 18m/min
- Output torque: 22.0 N.m
- Output gear module: M=4
- Output gear number: Z=16
- Remote control distance: 1200N
- Working humidity: 11KG
- Net weight: 4KG
- Protection Class: IP44
- Working temperature of motor: -20°C to 50°C
Product Usage Instructions:
1. General Safety:
Before starting the installation process, ensure that the gate
can be opened and closed manually without any obstruction.
2. Installation Overview:
The motor should be installed with the power off and unplugged.
By default, the gate motor opens the gate to the right-hand side.
Refer to Diagram 2 for default operation.
3. Installation Steps:
3.1 Installation of Motor Base Plate:
- Determine the position of the motor base plate and secure it to
a cement foundation using embedded bolts or expansion bolts. - If the gear rack is already installed on the door, match the
motor gear with the gear rack, determine the position of the base
plate, and fix it.
3.2 Installation of Gate Opener:
- Place the gate opener on the base plate and secure it using
hexagon screws.
Frequently Asked Questions (FAQ):
Q: How can I manually open or close the gate in case of a power
failure?
A: You can use the override keys provided with the product to
unlock the clutch and manually operate the gate.
Q: Can I adjust the automatic closing function of the gate
opener?
A: Yes, the automatic closing function is adjustable from 0 to
99 seconds.
“`
Automatic Sliding Gate Opener
User’s Manual
³ Thank you for purchasing the sliding gate opener. ³ Please read and follow all warnings, precautions and instructions
before installation and using. ³ Periodic checks of the opener are required to ensure safe operation. ³ Keep the manual for future reference.
Contents
1.General safety ························································ 1 2.Product description ················································ 2 3.Parameters ···························································· 3 4.Features of sliding gate opener ································ 3 5.Installation overview ··············································· 4
5.1 Installation of motor base plate ····························· (5) 5.2 Installation of gate opener ··································· (5) 5.3 Installation of racks ············································ (5) 5.4 Installation of limit magnet ··································· (6) 5.5 Function of clutch ·············································· (6) 6.Connection of the power supply ······························· 7 7.Control board instruction ········································ 7 7.1 Terminal and buttons instruction ··························· (7) 7.2 LED indicator ···················································· (8) 7.3 Control board wire diagram ·································· (8) 8.How to program or erase the remote ························ 10 9.How to use the remote to operate your gate opener ··· 11 10.Control board function description ························ 11 11.Control board digital display menu setting ············· 14 12. Smart module instruction ···································· 18 Add the device ······················································ (18) Share the device ·················································· (20) Remote assistance ················································ (21) Add USB card / RF remote control off/at site ················ (22) Management of the USB card and RF remote control ···· (23) Binding with camera ··············································· (23)
CHECK YOUR GATE
Before installation, please make sure that the gate itself can be opened and closed smoothly & freely BY HAND
WITHOUT THE GATE OPENER.
1. General safety
WARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or properties, should always request the assistance of qualified personnel. · This product was exclusively designed and manufactured for the use specified in the present documentation. Any other use not specified in this documentation could damage the product and be dangerous. · The factory declines all responsibility for any consequences resulting from improper use of the product, or use which is different from that expected and specified in the present documentation. · Do not install the product in explosive atmosphere or where there is any danger of flooding. · To AVOID damaging gas, power, or other underground utility lines, contact underground utility locating companies BEFORE digging. · Disconnect the electrical power supply before carrying out any work on the installation or maintenance. · Please ensure that the using power voltage matches with the supply voltage of gate opener (AC220V±10% 50Hz ). · To ensure safety, before installing the motor, all potential hazards and exposed pinch points of the gate must be eliminated or guarded prior, and make sure Gate End Stop and a Gate Stopper mounted at each end of the rail to prevent the gate travelling off the track. · Never mount any device that operates the gate motor where the user can reach over, under, around or through the gate to operate the controls. These must be placed at least 1.8m from any moving part of the moving gate. · Keep remote control and other control devices out of children’s reach, in order to avoid unintentional activation. · If required, install infrared photocells ( sold separately) to detect obstructions and prevent injury or damage. · Instruct all users about the control systems provided and the manual opening operation in case of emergency. · Anything which is not expressly provided for in these instructions is not allowed and will void warranty. · Only use original parts for any maintenance or repair operation. We decline all responsibility with respect to the automation safety and correct operation when other supplier’s components are used.
1
2. Product description
The PYM-K2202 motor was designed as a device for moving 1000KGS sliding gates. The way of the gear works prevents the gate from moving when the motor is turned off, so there is no need to use an electric lock. Avoid a power failure, user can use the override key to unlock the clutch to manual open or close the gate.
70mm 270mm
86mm
256mm 218mm
14mm
Part list
109mm
Diagram 1
Motorx1
Striker Plate Fixing Boltsx4
RHS/LHS Limit Switch Striker Platex2
Remote Control Optional
Remotex2
2
Motor to mounting plate screwsx4
Override keysx2
Optional accessories parts list (available at giant store)
Gear Rack
Photocell Sensor
Flash Lamp
TKM-01
WIFI&RF Receiver
3. Parameters
Bluetooth Controller
Power supply
Maximum load
Rated power Rated speed Open(close) speed
Output torque
Output gear module
Output gear number
Remote control distance Working humidity Maximum pull Net weight
Protection Class
Working temperature of motor
Packing
Wireless Push Button
Loop Detector
AC 220V 1000KGS
80W 1400RPM v=18m/min 22.0 N.m
M=4 Z=16 PHWHU 1200N 11KG
B -25°Cj +55°C In a standard carton
4. Features of sliding gate opener
6RIWVWDUWDQGVORZVWRS Automatic closing function adjustable from 0 to 99 seconds. Thermal protection against engine overheating. Anti-pinch protection in case of meeting an obstacle. Signaling the current operating status of the machine on the display. Ability to support up to 128pcs remote controls.
Possibility to connect external buttons and control devices (e.g.push button, Wi-Fi controller, radio receiver etc).
Possibility of partial opening of the gate, without the need to perform the full scope of work. Manual release of the gate in the event of a lack of 220V mains voltage. Add smart module for 2.4G Bluetooth control (optional).
3
5. Installation overview
Any works done to the motor must be completed whilst the power is off, and the motor is unplugged. The gate motor will open the gate to the right-hand side as its default setting (Refer to diagram 2).
Default operation: Motor mounted on the
right-hand side
Diagram 2 If gate need to open to the left-hand , then motor need to be installed on the left side of gate, as below picture(Diagram 3) showed.
Left-Hand Opening: Motor mounted on the
left-hand side
Diagram 3
4
5.1 Installation of motor base plate 1. Depending on the installation size of the motor and mounting height of racks, after determine the
installation position of the motor base plate, first let the bolt embedded or use expansion bolt to make base plate fixed on watering good cement foundation.
218mm
70mm
Diagram 4
2. If gear rack has been installed on door, motor can be fixed on it, use a allen key rotation to clutch “off ” position, after motor gear and gear rack match well to determine position of base plate, then remove motor and fix base plate.
5.2 Installation of gate opener 1. Put gate opener on base plate, use a random matching hexagon screw make the motor fixed on
the base plate.
2. Unscrew the screws fixed the motors cover, remove motor cover. According electrical wiring diagram, connected power cord, after adjust in good position, then install cover and use screws to fixed it.
5.3 Installation of racks 1. After the motor is installed,the racks teeth the down ,then put the gear on the motors.and final
connected with screws and gate.push the door with hand.so can let door sliding it and can move it without any problem.after confirmed,fixed the racks.
2. Rack is usually unit assembly,in order to avoid gate run jitter or jammed, rack and joint clearance must be corrected.Suggest use this way,see diagram3 with a small correction of the rackafter connecting right with racks 1 and racks 2 ,then fixed racks 1 and 2.
Rack 1
Correction of the rack Diagram 5
5
Rack 1
5.4 Installation of limit magnet
here are 2 limit magnet supplied. Note there is a left hand and a right hand magnet. The magnet should be installed one at either end of the rack. See Diagram 6.
To install the magnet in the correct position, open the clutch door and press the `CLOSE’ button on the remote, the motor will run but will not drive the gate. Close the gate manually and adjust the limit magnet to contact the toggle switch and switch the motor off at the desired gate position. To adjust the stop position of the gate when it is open, press the `OPEN’ button, manually open the gate and adjust the other limit magnet to contact the toggle switch and switch the motor off.
When you are satisfied the limit magnet are in the correct positions, tighten the screws in the limit magnet to clamp them to the rack, close the clutch door and using the remote control check the gate opens and closes to the desired positions. Adjust the limit magnet if necessary.
Blue
Open the gate from left-hand to right-hand(Diagram 2) Red
If you install the motor on the left of the gate, please adjust the blue and red limit magnet position as below picture show.
Open the gate from right-hand to left-hand(Diagram 3) Blue
Diagram 6
5.5 Function of clutch When the clutch is opened to the open position, you can manually push the door; when closing the clutch, electric door can run on, off, when touching limiting the bezel will stop automatically.
Diagram 7
Insert key. rotate 90 degrees
Releasing arm in torsion,wriggle 90 degress gate operator will be in releasing state
6
6. Connection of the power supply
WARNING! NEVER connect the gate opener to the power outlet before all the installations have been done.
Only use the AC electricity as the power source
Diagram 8
7.Control board instruction
Technical Parameters 1. Power supply: AC 220V 2. Power: 80W 3. Application: AC three phase asynchronous sliding gate opener 4. Remote control: Giant customized rolling code 5. Remote control memory: max support 128pcs Note: After user turned off the power for the control board, due to the existence of the large capacitance of
the board, there will be residual power, please do not touch the exposed wires of the board directly.
7.1 Terminal and buttons instruction
Limit Switch
D1 D2 D3
D4 D5 D6 D7
Digital Display
D8 D9 D10
Operation for PCB Function Setting/learning remote control/Pairing with smart module
Diagram 9 7
The following functions refer to the picture control board layout. 1 &2. Power: used for connecting with AC 220V power. 3 & 4. Lamp: used for connecting with flashing light, output voltage is AC 220V. 5 & 6 & 7. Motor: used for connecting with sliding gate motor’s wire. 8.VCC: DC 12V output used for connecting with external devices, max 100mA. 9.COM: used for connecting with COM terminal or GND. 10.Ph: used for connecting with the photocell sensor. 11.Start: It is a single button control mode switch for controlling the gate by “open -stop-close ” cycle. 12.COM: used for connecting with COM terminal or GND. 13.Close: used for connecting with any external devices that will operate to close the gate. 14.Open: used for connecting with any external devices that will operate to open the gate. 15.ANT: antenna connection. 16.LEARN: It is for programming/removing the remote control. 17.DEC/SMART: It is for figure decreasing of setting the data and add intelligent device. 18.FUN: Used for enter the menu setting and confirm the data. 19.INC/START: It is for figure increasing of setting the data and setting the single button control mode. 7.2 LED indicator D1: The photocell sensors output signal instructions
LED ON(Blue): Photocell sensors detection,if there have obstacle when closed the gate, the motor will stop running. LED OFF: Photocell sensors detection, there is no obstacle. D2: LED ON(Blue): Trigger the start terminal. D3: LED ON(Blue): Trigger the close terminal. D4: LED ON(Blue): Trigger the open terminal. D5: Indicate for operation of smart module D6: LED ON: the board with power on D7: Indicate for leaming/Delete remote control D8: Limit switch of closing the door LED ONThe door is not completely closedLED OFFThe door is completely closed D9: Limit switch of opening the door. LED ONThe door is completely opened. LED OFFThe door is not completely opened D10: LED ON(Blue): Warning light on flashing.. 7.3 Control board wire diagram
Diagram 10
Terminal , and is for connecting with the motor. If you want to install motor in the left-hand of gate, please enter the digital display menu to set the parameter J2 value from 0 to 1.
8
&RQQHFWZLWKIODVKODPS
Diagram 11
Terminal and is for connecting with the flash lamp .
&RQQHFWZLWKSKRWRFHOOVHQVRU
TX Connect terminal with the “COM ” of photocell RX. Connect terminal with the “OUT ” of photocell RX. Connect terminal with the “+ ” of photocell RX and TX. Connect terminal with the “- ” of photocell RX and TX.
Diagram 12 RX
&RQQHFWZLWKVWDUWWHUPLQDO Start terminal is used for connecting with some external devices , such push button, wired keypad, receiver etc.
Control gate by ” open-stop-close-stop-open ” mode
Terminal and is for connecting with the push button. Note! If you connect the wired keypad, etc devices, please also connect with
9
Vcc and
Com to get the power supply.
&RQQHFWZLWKRSHQFORVHJDWHGHYLFH
Open gate device:
Terminal and is for supplying the power to the push button. Terminal and is for connecting with the device.
Close gate device:
Terminal and is for supplying the power to the push button. Terminal and is for connecting with the device.
8.How to program or erase the remote
3URJUDPWKHUHPRWH3UHVVOHDUQEXWWRQIRUDWOHDVWVHFRQGDQGWKHQUHOHDVHWKH/(‘LQGLFDWRU will light on. Now user needs to press the button on the remote control, with the buzzer short beep, which means the code learning is successful, the digital LED will show the quantity of that remotes were learned.
After the user presses the learn button, within 8 seconds, if the controller doesn’t receive the signal from the remote, the controller’s LED indicator will turn out and exit the code learning statute. Note: Due to the digital display only can show two digital numbers, if the controller already learned more than 99pcs remote, from the 100th remote, the digital display will show A to replace the ten and hundred digits. Such as the 100th remote will show A0, and the 101st remote will show A1. If the controller already learned more than 109pcs remote, from the 110th remote, the digital display will show b to replace the ten and hundred digits. Such as the 110th remote will show b0. Max capacity: 128pcs remote. If the digital display show “- -” with a buzzer short beep 5 times, then means can not learn more remotes. (UDVHWKHUHPRWH3UHVVDQGKROGWKHOHDUQLQJEXWWRQIRUVHFRQGVZKLOHWKHXVHUKHDUVWKH
buzzer with a long beep, release the button, and the digital display show “00”. Now all remotes can not control the gate.
10
9.How to use the remote to operate your gate opener
Each remote has 4 buttons, can set them with different work mode independently through the digital display menu L1, L2, L3 and L4, 0: No function. 1: Open-Stop-Close… 2: Pedestrian mode 3: Open only. 4: Close only. 5: Stop only. 6: Turn auto close off via remote.
10.Control board function description
Item Power on
Z
After the control board powered on, the buzzer will sound, and the digital display will show model number and version,and the status indicator LED lit up.
Auto travel learning
The newly installed motor needs to operate the auto travel learning once before the high and low speeds can be normally allocated. After the auto travel learning completed, the gate motor will automatically allocated the high and slow speed. The high and slow speeds for opening and closing can be set through the digital display menu. 1. Before starting the auto travel learning, the gate must be fully closed. 2. Enter the menu, select Pr, set 5, and confirm to start the auto travel learning 3. The gate will automatically open and close with slow speed to remember the travel time. 4. The speed of slow speed for opening and closing separately through the menu. The larger the value, the more slow speed. 5. During the auto travel learning process, if any control occurs, such as RF control, Pedestrian terminal trigger, safety beam trigger, etc., the auto travel learning will be interrupted and the learning operation needs to be restarted. If the auto travel learning fails halfway, the buzzer will sound twice, and the learning will be long once if the learning is successful. Note: If Pr is set to 10, you can also enter the auto travel learning, but at this time it will run with the high speed set in the menu. It is recommended to select 5 to use the slow speed to learn the travel. After the slow speed auto travel learning, if you found that the high and slow speed distribution of the gate is not ideal, you can try to use the high-speed auto travel learning.
Setting slow speed running time
Setting running speed for opening and closing
After completed the auto-travel learning, the gate opener will automatic set the slow speed running time for opening and closing from 0 – 5 levels. The bigger the value is, the more slow speed running time. 0 means No slow speed running time.
The gate opener can set the high speed and slow speed for opening and closing from 0 – 5 levels. The bigger the value is, the higher speed running time. If adjust the running speed, please operate the auto-travel learning again.
Overcurrent
The overcurrent function can achieve an anti-smashing car. While the gate is opening, it detects the overcurrent and stop. If the gate is closing and detects the overcurrent, the user can set different response modes through the menu A9. 0: reverse back to the opened position. 1: reverse to open the gate for 1 second. 2: 1: reverse to open the gate for 3 seconds. 3: stop. Setting overcurrent for opening and closing the gate through the digital display menu.
11
Limit switch mode Safety beam mode
1. When the gate is fully opened/closed, and trigger the limit switch, the motor will auto stop.
2. The control board support to work with NO and NC limit switch, and can set the limit switch mode of NO and NC mode through the digital display menu.
3. The control board can switch the limit direction through the digital display menu. When the digital display show “Lr” means the limit switch detect a bug (limit error). Please check whether the limiter is damaged or in poor contact, or whether the normally open and normally closed mode (menu F0) set by the system does not match the actual limit switchtype.
The safety beam mode can be be selected by menu F2, the default mode is 1, it is normal open mode. 1. While the gate is closing, if the infrared signal meets an obstruction, the gate will
rebound to open. 2. If set the auto-closing timer after fully opening, the gate will be auto-closed. 3. If the safety beam signal exists, the gate closing action will not be executed and the
countdown time will always be reset.
Auto-closing timer for fully opening
1. The auto-closing function is only triggered after the gate is fully opened. 2. Auto close timer for fully opening can be set through the digital display menu. 3. When auto-close timer start to countdown, the STATE LED will flash one time
each second. 4. The remote button can set to cancel the auto-closing command once. 5. Note: Cancellation only cancels this time, and the gate can be auto-closing
next time when it is fully opened.
Flash Lamp Mode Motor protection
The digital display menu can set the lamp work mode. Mode 0: Flashing light and motor will operate and stop at the same time. Mode 1: Flashing light will turn off 30 seconds after the motor stop. NOTE: No matter you choose the mode 0 or mode 1, when the gate is on the auto close timer countdown statue, the lamp also will light on.
As soon as the motor runs continuously for more than the 120s, the motor will automatically stop working to protect the motor.
Setting of start terminal
The start terminal can be setting with different function through the digital display menu. 0: Fully Open-Stop-Close……(factory default) 1: Pedestrian Open-Stop-Close. 2: Open only. 3: Close only. 4: Stop only.
Setting of open terminal
The open terminal can be setting with different function through the digital display menu. 0: Fully Open-Stop-Close…… 1: Pedestrian Open-Stop-Close. 2: Open only.(factory default). 3: Close only. 4: Stop only.
12
Setting of close terminal
Pedestrian mode
Upgrade control board system by USB device
Smart module (optional)
The close terminal can be setting with different function through the digital display menu. 0: Fully Open-Stop-Close…… 1: Pedestrian Open-Stop-Close. 2: Open only. 3: Close only.(factory default) 4: Stop only.
The remote button and Pedestrian terminal can trigger the Pedestrian mode, the gate will partially open then stop, not fully open. This mode is convenient for users walking in and out. The pedestrian mode work with ” open-stop-close-stop…” The auto-closing timer after Pedestrian mode can set through the digital display menu.
1.Before you upgrade the system, please confirm the U disk document isFAT32 or not. If not, please format the U disk as FAT32. 2.Copy the upgrade file into the root directory of the U disk and name it EGB-16A.bin. 3. Insert the U disk into the upgrade module, and then connect the upgrade module to the USB port. 4. Enter the menu, select the Pr and set 5, and confirm. At this time, the system will restart, the digital tube will display UP, and the upgrade will begin. After the upgrade is completed, it will restart automatically.
1. Program the 2.4G transmitter: Short press the DEC/Smart button, the buzzer will sound once, smart indicator LED will light on, enter the programming mode. Transmit the 2.4G signal, if the indicator LED flash twice and keep lighting on, which means the programming is successful. Otherwise, after 8s will exit the programming mode automatically. 2. 2.4G control mode: while the mode received the 2.4G signal, it will
open the gate once. 3. Add the Bluetooth device: Open the XHouse IOT app, enter the add device mode, and choose the Bluetooth device. Choose the correct Bluetooth device, press the add button. (The Bluetooth device mode number is XHOUSE_092BLE_XXXXXX
XXXXXX is its serial number). 4. Bluetooth device control mode: On the app, there has three buttons, including open,
close and stop. 5. Initialize the Bluetooth device: Hold press the 2.4G button about 5s, while you hear
the buzzer sound two beep, release the button, the operation is complete. 6. Factory reset the Bluetooth device: Hold press the 2.4G button about 10s, while you
hear the buzzer sound with a long beep, release the button. After that, the module will erase all the 2.4G transmitter and initialize the Bluetooth device.
13
11. Control board digital display menu setting
³Press and hold the [FUN] button for 3 seconds, and the digital display will indicate “A0”, then release the button, now the menu can be set to [INC/START] and [DEC/SMART] for increasing and decreasing numbers or values.
³After adjusting the value, press the [FUN] button to store the data, and the buzzer will beep one time to show the store successfully.
³After the menu setting is finished, press the [LEARN] button to exit the menu setting and close the display.
Item Function description
A0
Opening overcurrent setting in high speed
Value 0~20 level
Factory default Explanation
Opening overcurrent setting in high
10
speed, the bigger the value is, the harder the motor to stop. Setting
value from 0-20.
A1
Closing overcurrent setting in high speed
0~20 level
Closing overcurrent setting in high
10
speed, the bigger the value is, the harder the motor to stop. Setting
value from 0-20.
A2
Opening overcurrent setting in slow speed
A3
Closing overcurrent setting in slow speed
0~20 level 0~20 level
Opening overcurrent setting in high
6
speed, the bigger the value is, the harder the motor to stop. Setting
value from 0-20.
Closing overcurrent setting in high
6
speed, the bigger the value is, the harder the motor to stop.
Setting value from 0-20.
A8 Overcurrent sensitivity
0-3 level
The bigger the value is, the longer
0
the overcurrent sensing time is.
Setting value from 0-3
A9 Overcurrent reaction for closing 0-3
0
B0
Setting slow speed running time for opening
0-5 level
2
B1
Setting slow speed running time for closing
0-5 level
2
14
Setting overcurrent reaction of gate: 0: Reverse back to the end. 1: Reverse back 1 second and stop. 2: Reverse back 3 seconds and stop. 3: Stop
Used for setting the slow speed running time of the gate opening, gate will run in slow speed within this setting, then change to high speed with its rest travel. Setting from 0-5 seconds.
Used for setting the slow speed running time of the gate closing, gate will run in slow speed within this setting, then change to high speed with its rest travel. Setting from 0-5 level.
Item Function description
C0
Auto-closing timer for fully opening
D0 Setting high speed for opening
D1 Setting high speed for closing
Value
Factory default Explanation
0-99 seconds
0
Setting from 0-99 seconds, 0 means No auto-closing for fully opening.
0-5 level
2
Setting speed of high speed for opening, setting from 0-5
0-5 level
2
Setting speed of high speed for closing, setting from 0-5
D2 Setting slow speed for opening 0-5 level D3 Setting slow speed for closing 0-5 level
2
Setting speed of slow speed for opening, setting from 0-5
2
Setting speed of slow speed for closing, setting from 0-5
E0 Pedestrian mode
E1
Auto closing timer for pedestrian mode
F0 Limit switch mode
F1 Switch the limit direction
F2 Safety beam mode
0-15 seconds
6
0-99 seconds
0
0-1
1
0-1
0
0-1
1
F3 Flash Lamp Mode
0-1
0
G0 Setting of start terminal
0-4
0
G2 Setting of open terminal
0-4
2
G5 Setting of close terminal
0-4
3
0 means No pedestrian mode.
0 means No auto-closing for pedestrian mode
0NC mode. 1NO mode.
0: Default direction. 1: Switch direction.
0NC mode. 1NO mode.
0: Flashing light and motor will operate and stop at the same time. 1: Flashing light will turn off 30 seconds after the motor stop.
0: Fully Open-Stop-Close…… 1: Pedestrian Open-Stop- Close. 2: Open only. 3: Close only. 4: Stop only.
0: Fully Open-Stop-Close…… 1: Pedestrian Open-Stop- Close. 2: Open only. 3: Close only. 4: Stop only.
0: Fully Open-Stop-Close…… 1: Pedestrian Open-Stop- Close. 2: Open only. 3: Close only. 4: Stop only
J1
Stop reaction distance in high speed
0-5
0
Setting from 0-5. The bigger the value is, the more abruptly the gate will stop.
J2
Switch the motor operation direction
0-1
0
0: Default direction. 1: Switch direction
15
Item Function description
L1
Button A function (Remote control)
L2
Button B function (Remote control)
L3
Button C function (Remote control)
L4
Button D function (Remote control)
Pr Trigger auto travelling learning
Pr Trigger auto travelling learning Po Factory reset
Value 0-6
0-6
0-6
0-6 0-10 0-10 0-10
Factory default
Explanation
0: No function.
1: Open-Stop-Close.
2: Pedestrian mode.
1
3: Open only.
4: Close only.
5: Stop only.
6: Turn auto close off via remote.
0: No function.
1: Open-Stop-Close.
2: Pedestrian mode.
0
3: Open only.
4: Close only.
5: Stop only.
6: Turn auto close off via remote.
0: No function.
1: Open-Stop-Close.
2: Pedestrian mode.
0
3: Open only.
4: Close only.
5: Stop only.
6: Turn auto close off via remote.
0: No function.
1: Open-Stop-Close.
2: Pedestrian mode.
6
3: Open only.
4: Close only.
5: Stop only.
6: Turn auto close off via remote
Setting from 0-10. Set 5 will trigger
the slow speed auto travel learning.
0
Set 10 will trigger the high speed
auto travel learning.
0 means No auto travel learning.
Setting from 0-10.
Set 5 will trigger to upgrade the
0
system.
0 means No upgrade the system.
0
Setting from 0-10. Set 5 will trigger to reset operation. 0 means No reset.
Control board digital display information show
1. When the gate is start to open, the digital display will show “OP” 2. When the gate is start to close, the digital display will show “CL” 3. After the gate stop moving, the digital display will show “–” 4. When the gate is fully opened, the digital display will show “LO” 5. When the gate is fully closed, the digital display will show “LC”
16
6. When the motor reaches max working time, the digital display will show “EC” 7. When the motor trigger the overcurrent in high speed, the digital display will show “OH” .
When the motor trigger the overcurrent in slow speed, the digital display will show “OL” . 8. After the photocell is activated, the digital display will show “PH” 9. After the PED mode is activated, the digital display will show “Pd” 10.After the motor protection is activated, the digital display will show “HE” 11.When the limit switch broken or has a bug, the digital display will show “Lr” 12. Cancel the auto-closing, the digital display will show “CC”
17
12. Smart module instruction
Search “XHouse IOT” and download it from Google play or App Store
GET IT ON
FOR Android & IOS
2UVFDQWKLV45FRGHIRUGRZQORDG$33³;+RXVH,27´DQGLQVWDOOLW5HJLVWHUWKHDFFRXQWIRU “XHouse IOT”and log in.
Add the device Step 1. Power on the device, open the APP. Press the “” on the top right corner to add the device, then select the ” Sliding Gate ” which has a orange cycle on the top right corner. (Fig 1 and 2) ®If there has a gray cycle on the top right corner, that means the device already be added. The user
need to press and hold the “Dec/Smart” button for about 5s on the control board, then repeat the step 1. ®If there has a message “Please enter distribution network mode and add devices”, the user need to press and hold the “Dec/Smart” button for about 5s on the control board, then repeat the step 1. Step 2. Select the Wi-Fi, click the “Connect” and enter the password.(Fig 3) (If there hasn’t Wi-Fi can be connected, the user also can select the ” Bluetooth Add ” and use the Bluetooth function to control the gate nearly. Please follow the step 4). Step 3. Add the device successfully. The user can modify the name of the device and button from the ” “on the top right corner. (Fig 5) Step 4: Bluetooth Add: When using Bluetooth mode control, the mobile app must be close to the device within Bluetooth range to connect and control, and only one user’s phone can be connected at a time. (Fig. 3 and 4).
Fig 1
Fig 2 18
Fig 3
Fig 4
Fig 5
Device supports WIFI and bluetooth working mode ®When the device is connected to WiFi network successfully, it supports remote control and settings
the device through the mobile phone APP.cFig 5
®When the device is offline or the mobile phone has no network, if the user is nearly the device within 10 meters, and open the APP, it will automatically switch to the Bluetooth mode to control the device. (Fig 6)
®The device will establish a Bluetooth connection with the mobile phone to achieve close-range Bluetooth control (only one user’s mobile phone can establish a Bluetooth connection at the same time).
Fig 5
Fig 6
19
Switch WiFi network or bluetooth mode If the user need to switch to use a new WiFi network or want to switch control mode from the Bluetooth mode to WiFi mode, please follow the steps. Step 1. Select the device, press the ” “on the top right corner. Click the ” Set/Modify WiFi “. (Fig 7) Step 2. Select the new WiFi and connect it. And click the “Refresh”. (Fig 8)
Fig 7
Fig 8
Share the device
Step 1. Open the APP, select the device. Press the ” ” on the top right corner, then select to ³6KDULQJGHYLFH´ZLOOFUHDWHD45FRGH)LJ
Step 2. The new user download the APP and open it, Press the “Scan” on the top right corner to scan WKH45FRGH)LJ
Fig 9
Fig 10
20
Device settings
The user can set the parameters from the APP for the control board. Step 1. Select the device, press the ” “on the top right corner. Click the ” Setting “. (Fig 11)
Step 2. Set the parameters on the APP. (Fig 12)
Note: While the user want to set the parameters, the device must connect with the Wi-Fi. If not, the user need to use the Bluetooth function and put the phone app as close as the device to set the parameters. After done, please click the “Sync” button.
Remote assistance
Fig 11
Fig 12
When your equipment fails, the parameter settings need to be readjusted. At this time, you can directly LQLWLDWHWKH³5HPRWH$VVLVWDQFH´EXWWRQDQGVKDUHWKH45FRGHRUYHULILFDWLRQFRGHZLWKRXULQVWDOODWLRQ service provider for the remote service.
Fig 13 21
Fig 14
Add USB card / RF remote control at site
When the user need to add a RF remote control or a USB card to open the gate, you can use the “Add Card / Remote Control control at site” function to do it, and scan the QR code from the remote control or enter the ID number for the USB card. Don’t need to open the control box to program them.
Fig 15
Fig 16
Add USB card/RF remote off site
When the user needs to add an RF remote control or USB proximity card to open the gate, you can directly use the “Add USB card/RF remote off site” function, click the “Learn” button, and click “Start Learning”. Don’t need to open the control box, and the control board will enter the code learning state, and then press the remote control button or power on the USB card to transmit a signal.
Fig 17 22
Fig 18
Management of the USB card and RF remote control The card list can management your USB card and RF remote control. The user can sync all the cards and remotes to the card list for management, and delete it when they are no longer needed or lost.
Fig 19 Binding with camera Step 1. Open the APP, select the device. Press the ” ” on the top right corner, then select to ” Binding camera “. Step 2. Select the ” IP camera “, and press the ” Comfirm ” to confirm it.
Fig 20
Fig 21
23
Documents / Resources
![]() |