Automatic Sliding Gate Opener

User's Manual

Thank you for purchasing the sliding gate opener.

Please read and follow all warnings, precautions and instructions before installation and using.

Periodic checks of the opener are required to ensure safe operation.

Keep the manual for future reference.

1. General safety

WARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or properties. Always request the assistance of qualified personnel.

2. Product description

The PYM-K2202 motor was designed as a device for moving 1000KGS sliding gates. The way the gear works prevents the gate from moving when the motor is turned off, so there is no need to use an electric lock. Avoid a power failure; the user can use the override key to unlock the clutch to manually open or close the gate.

Diagram 1: Shows the dimensions of the gate opener motor.

Part list:

3. Parameters

Parameter Value
Power supply AC 220V
Maximum load 1000KGS
Rated power 80W
Rated speed 1400RPM
Open(close) speed v=18m/min
Output torque 22.0 N.m
Output gear module M=4
Output gear number Z=16
Remote control distance ≤50meter
Working humidity ≤85%
Maximum pull 1200N
Net weight 11KG
Protection Class B
Working temperature of motor -25°C~+55°C
Packing In a standard carton

4. Features of sliding gate opener

5. Installation overview

Any works done to the motor must be completed whilst the power is off, and the motor is unplugged.

The gate motor will open the gate to the right-hand side as its default setting (Refer to diagram 2).

Diagram 2: Default operation with motor mounted on the right-hand side.

If the gate needs to open to the left-hand, the motor needs to be installed on the left side of the gate, as shown in the picture (Diagram 3).

Diagram 3: Left-Hand Opening with motor mounted on the left-hand side.

5.1 Installation of motor base plate

  1. Depending on the installation size of the motor and mounting height of racks, after determining the installation position of the motor base plate, first let the bolt embedded or use an expansion bolt to fix the base plate on a good cement foundation.

Diagram 4: Shows the motor dimensions for base plate installation.

  1. If the gear rack has been installed on the door, the motor can be fixed on it. Use an Allen key to rotate the clutch to the "off" position. After the motor gear and gear rack match well, determine the position of the base plate, then remove the motor and fix the base plate.

5.2 Installation of gate opener

  1. Put the gate opener on the base plate, use a matching hexagon screw to fix the motor on the base plate.
  2. Unscrew the screws fixing the motor's cover, remove the motor cover. According to the electrical wiring diagram, connect the power cord. After adjusting to a good position, install the cover and use screws to fix it.

5.3 Installation of racks

  1. After the motor is installed, with the racks teeth facing down, put the gear on the motor. Finally, connect with screws and the gate. Push the door by hand to allow it to slide smoothly without any problem. After confirmation, fix the racks.
  2. Rack is usually unit assembly. To avoid gate run jitter or jamming, rack and joint clearance must be corrected. Suggest using this method: see diagram 3 with a small correction of the rack. After connecting right with racks 1 and racks 2, then fix racks 1 and 2.

Diagram 5: Illustrates rack installation and correction.

5.4 Installation of limit magnet

There are 2 limit magnets supplied. Note there is a left-hand and a right-hand magnet. The magnet should be installed one at either end of the rack. See Diagram 6.

To install the magnet in the correct position, open the clutch door and press the 'CLOSE' button on the remote. The motor will run but will not drive the gate. Close the gate manually and adjust the limit magnet to contact the toggle switch and switch the motor off at the desired gate position. To adjust the stop position of the gate when it is open, press the 'OPEN' button, manually open the gate and adjust the other limit magnet to contact the toggle switch and switch the motor off.

When you are satisfied the limit magnets are in the correct positions, tighten the screws in the limit magnet to clamp them to the rack, close the clutch door, and using the remote control, check the gate opens and closes to the desired positions. Adjust the limit magnet if necessary.

Diagram 6: Shows the placement of limit magnets for left-hand and right-hand opening.

5.5 Function of clutch

When the clutch is opened to the open position, you can manually push the door. When closing the clutch, the electric door can run on/off. Upon touching the limit bezel, it will stop automatically.

Diagram 7: Illustrates the clutch operation: inserting the key and rotating 90 degrees to release the arm.

6. Connection of the power supply

WARNING! NEVER connect the gate opener to the power outlet before all installations have been done. Only use AC electricity as the power source.

Diagram 8: Shows the power supply connection terminals for Power, Lamp, and Motor.

7. Control board instruction

Technical Parameters:

  1. Power supply: AC 220V
  2. Power: 80W
  3. Application: AC three-phase asynchronous sliding gate opener
  4. Remote control: Giant customized rolling code
  5. Remote control memory: max support 128pcs

Note: After turning off the power for the control board, due to the existence of large capacitance on the board, there will be residual power. Please do not touch the exposed wires of the board directly.

7.1 Terminal and buttons instruction

Diagram 9: Shows the control board layout with labeled terminals and indicators.

The following functions refer to the picture control board layout:

7.2 LED indicator

7.3 Control board wire diagram

Diagram 10: Wiring diagram for motor installation on the right side of the gate, showing connections for Power, Lamp, and Motor with color coding (Red, Yellow, Blue).

Terminals 5, 6, and 7 are for connecting with the motor.

If you want to install the motor in the left-hand of the gate, please enter the digital display menu to set the parameter J2 value from 0 to 1.

Connect with flash lamp

Diagram 11: Shows the connection of a flash lamp to terminals 3 and 4.

Terminals 3 and 4 are for connecting with the flash lamp.

Connect with photocell sensor

Diagram 12: Illustrates the connection of a photocell sensor (TX and RX) to the control board terminals.

Connect with start terminal

The start terminal is used for connecting with some external devices, such as a push button, wired keypad, receiver etc., to control the gate by "open-stop-close-stop-open" mode.

Diagram: Shows the connection of a push button to terminals 8 and 12.

Terminals 8 and 12 are for connecting with the push button.

Note: If you connect wired keypads or other devices, please also connect with 8 (Vcc) and 9 (Com) to get the power supply.

Connect with open/close gate device

Diagram: Shows the connection of open/close gate devices to terminals 8, 9, 10, 11, 12, 13, 14, 15.

8. How to program or erase the remote

After the user presses the learn button, if the controller does not receive the signal from the remote within 8 seconds, the controller's LED indicator will turn out and exit the code learning state.

Note: Due to the digital display only showing two digital numbers, if the controller has learned more than 99 remotes, from the 100th remote, the digital display will show 'A' to replace the ten and hundred digits (e.g., the 100th remote will show A0, and the 101st remote will show A1). If the controller has learned more than 109 remotes, from the 110th remote, the digital display will show 'b' to replace the ten and hundred digits (e.g., the 110th remote will show b0).

Max capacity: 128 remotes. If the digital display shows "--" with a buzzer short beep 5 times, then no more remotes can be learned.

9. How to use the remote to operate your gate opener

Each remote has 4 buttons, which can be set with different work modes independently through the digital display menu: L1, L2, L3, and L4.

10. Control board function description

Item Function description Value Factory default Explanation
Power on After the control board is powered on, the buzzer will sound, and the digital display will show the model number and version, and the status indicator LED will light up.
Auto travel learning The newly installed motor needs to operate the auto travel learning once before the high and low speeds can be normally allocated. After the auto travel learning is completed, the gate motor will automatically allocate the high and slow speeds. The high and slow speeds for opening and closing can be set through the digital display menu.
1. Before starting the auto travel learning, the gate must be fully closed.
2. Enter the menu, select Pr, set 5, and confirm to start the auto travel learning.
3. The gate will automatically open and close with slow speed to remember the travel time.
4. The speed of slow speed for opening and closing can be set separately through the menu. The larger the value, the slower the speed.
5. During the auto travel learning process, if any control occurs (e.g., RF control, Pedestrian terminal trigger, safety beam trigger, etc.), the auto travel learning will be interrupted, and the learning operation needs to be restarted. If the auto travel learning fails halfway, the buzzer will sound twice. If the learning is successful, the buzzer will sound once.
Note: If Pr is set to 10, you can also enter the auto travel learning, but it will run with the high speed set in the menu. It is recommended to select 5 to use the slow speed to learn the travel. After the slow speed auto travel learning, if you find that the high and slow speed distribution of the gate is not ideal, you can try to use the high-speed auto travel learning.
Setting slow speed running time 0-5 levels 2 After completing the auto-travel learning, the gate opener will automatically set the slow speed running time for opening and closing from 0-5 levels. The bigger the value, the more slow speed running time. 0 means no slow speed running time.
Setting running speed for opening and closing 0-5 levels 2 The gate opener can set the high speed and slow speed for opening and closing from 0-5 levels. The bigger the value, the higher the speed. If you adjust the running speed, please operate the auto-travel learning again.
Overcurrent The overcurrent function can achieve an anti-smashing car. While the gate is opening, it detects the overcurrent and stops. If the gate is closing and detects the overcurrent, the user can set different response modes through the menu A9.
0: reverse back to the opened position.
1: reverse to open the gate for 1 second.
2: reverse to open the gate for 3 seconds.
3: stop.
Setting overcurrent for opening and closing the gate through the digital display menu.
Limit switch mode 1. When the gate is fully opened/closed, and triggers the limit switch, the motor will auto stop.
2. The control board supports working with NO and NC limit switches, and can set the limit switch mode of NO and NC mode through the digital display menu.
3. The control board can switch the limit direction through the digital display menu. When the digital display shows "Lr", it means the limit switch detected a bug (limit error). Please check whether the limiter is damaged or in poor contact, or whether the normally open and normally closed mode (menu F0) set by the system does not match the actual limit switch type.
Safety beam mode The safety beam mode can be selected by menu F2; the default mode is 1, which is normal open mode.
1. While the gate is closing, if the infrared signal meets an obstruction, the gate will rebound to open.
2. If the auto-closing timer is set after fully opening, the gate will be auto-closed.
3. If the safety beam signal exists, the gate closing action will not be executed, and the countdown time will always be reset.
Auto-closing timer for fully opening 1. The auto-closing function is only triggered after the gate is fully opened.
2. Auto close timer for fully opening can be set through the digital display menu.
3. When the auto-close timer starts to countdown, the STATE LED will flash once each second.
4. The remote button can be used to cancel the auto-closing command once.
5. Note: Cancellation only cancels this time; the gate can be auto-closing next time when it is fully opened.
Flash Lamp Mode The digital display menu can set the lamp work mode.
Mode 0: Flashing light and motor will operate and stop at the same time.
Mode 1: Flashing light will turn off 30 seconds after the motor stops.
NOTE: Regardless of the chosen mode (0 or 1), when the gate is in the auto-close timer countdown state, the lamp will also light up.
Motor protection As soon as the motor runs continuously for more than 120 seconds, the motor will automatically stop working to protect the motor.
Setting of start terminal The start terminal can be set with different functions through the digital display menu. 0-4 0 0: Fully Open-Stop-Close... (factory default)
1: Pedestrian Open-Stop-Close.
2: Open only.
3: Close only.
4: Stop only.
Setting of open terminal The open terminal can be set with different functions through the digital display menu. 0-4 2 0: Fully Open-Stop-Close...
1: Pedestrian Open-Stop-Close.
2: Open only. (factory default)
3: Close only.
4: Stop only.
Setting of close terminal The close terminal can be set with different functions through the digital display menu. 0-4 3 0: Fully Open-Stop-Close...
1: Pedestrian Open-Stop-Close.
2: Open only.
3: Close only. (factory default)
4: Stop only.
Pedestrian mode The remote button and Pedestrian terminal can trigger the Pedestrian mode. The gate will partially open then stop, not fully open. This mode is convenient for users walking in and out. The pedestrian mode works with "open-stop-close-stop..." 0-15 seconds 6 0 means No pedestrian mode.
The auto-closing timer after Pedestrian mode can be set through the digital display menu. 0-99 seconds 0 0 means No auto-closing for pedestrian mode.
Upgrade control board system by USB device 1. Before you upgrade the system, please confirm the U disk document is FAT32 or not. If not, please format the U disk as FAT32.
2. Copy the upgrade file into the root directory of the U disk and name it EGB-16A.bin.
3. Insert the U disk into the upgrade module, and then connect the upgrade module to the USB port.
4. Enter the menu, select the Pr and set 5, and confirm. At this time, the system will restart, the digital tube will display UP, and the upgrade will begin. After the upgrade is completed, it will restart automatically.
0-1 1 0: NC mode. 1: NO mode.
0-1 0 0: Default direction. 1: Switch direction.
0-1 1 0: NC mode. 1: NO mode.
0-1 0 0: Flashing light and motor will operate and stop at the same time.
1: Flashing light will turn off 30 seconds after the motor stop.
0-4 0 0: Fully Open-Stop-Close......
1: Pedestrian Open-Stop- Close.
2: Open only.
3: Close only.
4: Stop only.
0-4 2 0: Fully Open-Stop-Close......
1: Pedestrian Open-Stop- Close.
2: Open only. (factory default)
3: Close only.
4: Stop only.
0-4 3 0: Fully Open-Stop-Close......
1: Pedestrian Open-Stop- Close.
2: Open only.
3: Close only. (factory default)
4: Stop only.
Stop reaction distance in high speed Setting from 0-5. The bigger the value is, the more abruptly the gate will stop. 0-5 0
Switch the motor operation direction 0: Default direction.
1: Switch direction.
0-1 0
Button A function (Remote control) 0: No function.
1: Open-Stop-Close.
2: Pedestrian mode.
3: Open only.
4: Close only.
5: Stop only.
6: Turn auto close off via remote.
0-6 1
Button B function (Remote control) 0: No function.
1: Open-Stop-Close.
2: Pedestrian mode.
3: Open only.
4: Close only.
5: Stop only.
6: Turn auto close off via remote.
0-6 0
Button C function (Remote control) 0: No function.
1: Open-Stop-Close.
2: Pedestrian mode.
3: Open only.
4: Close only.
5: Stop only.
6: Turn auto close off via remote.
0-6 0
Button D function (Remote control) 0: No function.
1: Open-Stop-Close.
2: Pedestrian mode.
3: Open only.
4: Close only.
5: Stop only.
6: Turn auto close off via remote.
0-6 6
Pr Trigger auto travelling learning Setting from 0-10. Set 5 will trigger the slow speed auto travel learning. Set 10 will trigger the high speed auto travel learning. 0 means No auto travel learning. 0-10 0
Pr Trigger auto travelling learning Setting from 0-10. Set 5 will trigger to upgrade the system. 0 means No upgrade the system. 0-10 0
Po Factory reset Setting from 0-10. Set 5 will trigger to reset operation. 0 means No reset. 0-10 0

Control board digital display information show:

  1. When the gate starts to open, the digital display will show "OP".
  2. When the gate starts to close, the digital display will show "CL".
  3. After the gate stops moving, the digital display will show "--".
  4. When the gate is fully opened, the digital display will show "LO".
  5. When the gate is fully closed, the digital display will show "LC".
  6. When the motor reaches max working time, the digital display will show "EC".
  7. When the motor triggers the overcurrent in high speed, the digital display will show “OH”. When the motor triggers the overcurrent in slow speed, the digital display will show "OL”.
  8. After the photocell is activated, the digital display will show “PH”.
  9. After the PED mode is activated, the digital display will show "Pd".
  10. After the motor protection is activated, the digital display will show “HE”.
  11. When the limit switch is broken or has a bug, the digital display will show "Lr".
  12. Cancel the auto-closing, the digital display will show "CC".

11. Control board digital display menu setting

Press and hold the [FUN] button for 3 seconds, and the digital display will indicate "A0", then release the button. Now the menu can be set using [INC/START] and [DEC/SMART] for increasing and decreasing numbers or values.

After adjusting the value, press the [FUN] button to store the data, and the buzzer will beep once to show the store was successful.

After the menu setting is finished, press the [LEARN] button to exit the menu setting and close the display.

Item Function description Value Factory default Explanation
A0 Opening overcurrent setting in high speed 0~20 level 10 Opening overcurrent setting in high speed; the bigger the value is, the harder the motor to stop. Setting value from 0-20.
A1 Closing overcurrent setting in high speed 0~20 level 10 Closing overcurrent setting in high speed; the bigger the value is, the harder the motor to stop. Setting value from 0-20.
A2 Opening overcurrent setting in slow speed 0~20 level 6 Opening overcurrent setting in high speed; the bigger the value is, the harder the motor to stop. Setting value from 0-20.
A3 Closing overcurrent setting in slow speed 0~20 level 6 Closing overcurrent setting in high speed; the bigger the value is, the harder the motor to stop. Setting value from 0-20.
A8 Overcurrent sensitivity 0-3 level 0 The bigger the value is, the longer the overcurrent sensing time is. Setting value from 0-3.
A9 Overcurrent reaction for closing 0-3 0 Setting overcurrent reaction of gate:
0: Reverse back to the end.
1: Reverse back 1 second and stop.
2: Reverse back 3 seconds and stop.
3: Stop.
B0 Setting slow speed running time for opening 0-5 level 2 Used for setting the slow speed running time of the gate opening; the gate will run in slow speed within this setting, then change to high speed with its rest travel. Setting from 0-5 seconds.
B1 Setting slow speed running time for closing 0-5 level 2 Used for setting the slow speed running time of the gate closing; the gate will run in slow speed within this setting, then change to high speed with its rest travel. Setting from 0-5 level.
C0 Auto-closing timer for fully opening 0-99 seconds 0 Setting from 0-99 seconds, 0 means No auto-closing for fully opening.
D0 Setting high speed for opening 0-5 level 2 Setting speed of high speed for opening, setting from 0-5.
D1 Setting high speed for closing 0-5 level 2 Setting speed of high speed for closing, setting from 0-5.
D2 Setting slow speed for opening 0-5 level 2 Setting speed of slow speed for opening, setting from 0-5.
D3 Setting slow speed for closing 0-5 level 2 Setting speed of slow speed for closing, setting from 0-5.
E0 Pedestrian mode 0-15 seconds 6 0 means No pedestrian mode.
E1 Auto closing timer for pedestrian mode 0-99 seconds 0 0 means No auto-closing for pedestrian mode.
F0 Limit switch mode 0-1 1 0: NC mode. 1: NO mode.
F1 Switch the limit direction 0-1 0 0: Default direction. 1: Switch direction.
F2 Safety beam mode 0-1 1 0: NC mode. 1: NO mode.
F3 Flash Lamp Mode 0-1 0 0: Flashing light and motor will operate and stop at the same time.
1: Flashing light will turn off 30 seconds after the motor stop.
G0 Setting of start terminal 0-4 0 0: Fully Open-Stop-Close......
1: Pedestrian Open-Stop- Close.
2: Open only.
3: Close only.
4: Stop only.
G2 Setting of open terminal 0-4 2 0: Fully Open-Stop-Close......
1: Pedestrian Open-Stop- Close.
2: Open only. (factory default)
3: Close only.
4: Stop only.
G5 Setting of close terminal 0-4 3 0: Fully Open-Stop-Close......
1: Pedestrian Open-Stop- Close.
2: Open only.
3: Close only. (factory default)
4: Stop only.
J1 Stop reaction distance in high speed 0-5 0 Setting from 0-5. The bigger the value is, the more abruptly the gate will stop.
J2 Switch the motor operation direction 0-1 0 0: Default direction.
1: Switch direction.

12. Smart module instruction

Search "XHouse IOT" and download it from Google Play or App Store.

QR Code: Link to download the "XHouse IOT" app for Android & iOS.

Or scan this QR code for download APP "XHouse IOT" and install it. Register the account for "XHouse IOT" and log in.

Add the device

  1. Power on the device, open the APP. Press the "+" on the top right corner to add the device, then select "Sliding Gate" which has an orange cycle on the top right corner. (Fig 1 and 2)
  2. If there is a gray cycle on the top right corner, that means the device is already added. The user needs to press and hold the “Dec/Smart” button for about 5s on the control board, then repeat step 1.
  3. If there is a message “Please enter distribution network mode and add devices”, the user needs to press and hold the “Dec/Smart” button for about 5s on the control board, then repeat step 1.
  4. Select the Wi-Fi, click "Connect" and enter the password. (Fig 3) (If Wi-Fi cannot be connected, the user can also select "Bluetooth Add" and use the Bluetooth function to control the gate nearby. Please follow step 4).
  5. Add the device successfully. The user can modify the name of the device and button from the "" on the top right corner. (Fig 5)
  6. Bluetooth Add: When using Bluetooth mode control, the mobile app must be close to the device within Bluetooth range to connect and control, and only one user's phone can be connected at a time. (Fig. 3 and 4).

Fig 1, 2, 3, 4, 5: Illustrate the process of adding a device via the XHouse IOT app.

Switch WiFi network or bluetooth mode

If the user needs to switch to a new WiFi network or switch control mode from Bluetooth to WiFi, please follow the steps.

  1. Select the device, press the "" on the top right corner. Click "Set/Modify WiFi". (Fig 7)
  2. Select the new WiFi and connect it. Click "Refresh". (Fig 8)

Fig 7, 8: Show the steps for modifying WiFi settings.

Share the device

  1. Open the APP, select the device. Press the "" on the top right corner, then select "Sharing device" to create a QR code. (Fig 9)
  2. The new user downloads the APP and opens it. Press "Scan" on the top right corner to scan the QR code. (Fig 10)

Fig 9, 10: Illustrate the process of sharing the device via QR code.

Device settings

The user can set the parameters from the APP for the control board.

  1. Select the device, press the "" on the top right corner. Click "Setting". (Fig 11)
  2. Set the parameters on the APP. (Fig 12)

Note: To set parameters, the device must be connected to Wi-Fi. If not, the user needs to use the Bluetooth function and place the phone app close to the device to set the parameters. After completion, click the "Sync" button.

Fig 11, 12: Show the device settings interface in the app.

Remote assistance

When equipment fails, parameter settings may need readjustment. Initiate the "Remote Assistance" button and share the QR code or verification code with your installation service provider for remote service.

Fig 13, 14: Illustrate the remote assistance feature, including authorization codes and device information.

Add USB card / RF remote control at site

To add an RF remote control or a USB card to open the gate, use the "Add Card / Remote Control at site" function. Scan the QR code from the remote control or enter the ID number for the USB card. No need to open the control box to program them.

Fig 15, 16: Show the interface for adding USB card/RF remote control at site.

Add USB card/RF remote off site

To add an RF remote control or USB proximity card to open the gate, use the "Add USB card/RF remote off site" function. Click the "Learn" button, then click "Start Learning". No need to open the control box; the control board will enter the code learning state. Then press the remote control button or power on the USB card to transmit a signal.

Fig 17, 18: Show the interface for adding USB card/RF remote control off site.

Management of the USB card and RF remote control

The card list can manage your USB card and RF remote control. The user can sync all cards and remotes to the card list for management, and delete them when no longer needed or lost.

Fig 19: Shows the card list management interface.

Binding with camera

  1. Open the APP, select the device. Press the "" on the top right corner, then select "Binding camera".
  2. Select "IP camera", and press "Confirm" to confirm it.

Fig 20, 21: Illustrate the process of binding a camera.

Models: K2202-CX-EGB-16-WIFI, 2025, K2202-CX-EGB-16-WIFI Automatic Sliding Gate Opener, K2202-CX-EGB-16-WIFI, Automatic Sliding Gate Opener, Sliding Gate Opener, Gate Opener, Opener

File Info : application/pdf, 25 Pages, 2.19MB

PDF preview unavailable. Download the PDF instead.

1cbc8e255adacaa03893cafc56c45207

References

GPL Ghostscript 9.53.3 Aspose Ltd.

Related Documents

Preview Sliding Gate Opener User's Manual - PYM-B024
This user's manual provides comprehensive instructions for the PYM-B024 Sliding Gate Opener, covering safety, installation, operation, and maintenance. Learn about its features, technical specifications, and control board functions.