PROLINE 1300 CFM Inline Blower Installation Guide

1300 CFM Inline Blower

Product Specifications:

  • Model: Proline Inline Blower
  • CFM: 1300
  • Power Outlet: 120v
  • Wiring: Type NM Cable ‘ROMEX’
  • Location: Attic or Kitchen Space

Product Usage Instructions:

Before Installation:

Do not proceed with installation if the blower is damaged or
unsatisfactory.

Mounting the Blower:

  1. Lift the blower to the mounting location and secure it to the
    attic framing or studs.
  2. Use sound-dampening material to reduce vibration noise.
  3. Ensure correct orientation by following the airflow direction
    marked on the unit.

Checking the Installation:

Verify that the blower is securely fastened and stable. Tighten
screws if needed.

Connecting Ductwork:

  • Use self-tapping screws to secure the duct to the blower.
  • Use HVAC foil tape to prevent air leaks.
  • Ensure the duct diameter is at least 10 inches and do not
    reduce it.

Running Power to the Blower:

All wiring must be done by a licensed electrician following
local codes. Refer to the wiring diagram for proper
connections.

Frequently Asked Questions (FAQ):

Q: Can I install the blower myself?

A: It is recommended to have a qualified professional, such as a
licensed general contractor, install the range hood. Electrical
wiring should be done by a licensed electrician familiar with local
regulations to prevent any safety hazards.

Loading PDF…
Download PDF

Proline Inline Blower
(1300 CFM Model)
Installation Guide
IMPORTANT: Read and save these instructions. NOTICE:
Installer: Leave this guide with the homeowner Homeowner: Keep this guide for future reference

Proline Inline Blower Installation Guide
Before the Installation
1. Inspect Your Inline Blower: · Plug in test controls and fan. · Inspect for any damage caused during shipping. · Report any damage to Proline Customer Service within 5 DAYS OF RECEIPT of blower by calling 877.901.5530 or emailing support@prolinerangehoods.com.
NOTE: Do not install the blower if it’s damaged or you’re unsatisfied with it. 2. Find Blower Mounting Location and Prepare Ductwork:
· Identify an area along the desired path of your existing ductwork where you have enough room to mount the inline blower. The location should be a solid wall, stud, part of your home’s structure, or a framed area within your attic that is structurally sound enough to support the blower.
· Ensure that both points on the mounting bracket will be mounted to a stud, rafter, or joist. · The existing ductwork will dictate the best placement for the blower to ensure optimal performance.
Inline Blower Installation
Refer to the diagram for detailed reference.
Step 1: Mount the Blower
Lift the blower to the mounting location and fasten it securely to the attic framing or studs. To help reduce vibration noise, place sound-dampening material (such as rubber pads or foam) between the blower brackets and the mounting surface. Make sure the blower is installed in the correct orientation by following the airflow direction marked on the side of the unit.
Step 2: Check the Installation
Verify that the blower is securely fastened to the studs or sturdy framing material. Tighten any screws as necessary to ensure the blower is stable and securely mounted.
2

Step 3: Connect Ductwork to the Blower

DUCT WORK

3 x Self-tapping Screws and
HVAC Foil Tape
3 x Self-tapping Screws and
HVAC Foil Tape

Note: The duct diameter must be at least 10″. Do not reduce duct size.

· If your ductwork (B) does not match

B

the diameter of the blower (A), install

transition pieces between the two

connections.

· Attach ductwork (B) to both ends of the

blower (A). A

· At each connection point, insert three

self-tapping screws, spaced evenly

around the circumference, to secure the

duct.

B

· Seal all joints thoroughly with HVAC foil

tape to prevent air leaks.

Step 4: Run Power to the Blower

Attic Space Kitchen Space

In-line Blower
CCeeiilliinngg

Airflow

Airflow

Green

N

Blue

Black

L

C

Brown
Wiring

Type NM Cable `ROMEX’

Junction Box
Power Outlet 120v

Range Hood

I ALL WIRING MUST BE DONE BY A LICENSED ELECTRICIAN AND FOLLOW LOCAL CODES.
· The blower’s power cord must connect to the range hood’s junction box. Use codecompliant wiring (e.g., Type NM/ROMEX) to extend power from the blower.
· Splice the blower wires to a 3-prong power cord using proper connections. Match colors as follows:
· Green (Ground), Blue (Neutral), Black (Live), Brown/C (Control, if needed).
· Plug the cord into the back of the hood and route it securely along framing or ductwork to prevent damage

That wraps up your inline blower installation! Great work! We are happy to help you with any questions or concerns you may have. Please create a ticket, email us at support@prolinerangehoods.com or call our support line at (877) 901-5530 to talk to a live representative.
3

Proline Inline Blower Installation Guide
Safety Information
Ask a qualified professional such as a licensed general contractor to install your range hood. Electrical wiring must be installed, insulated, and grounded by a licensed electrician familiar with your local codes and regulations. If you don’t have this background, do not install the hood yourself. Poor installation or electrical work may result in an injury.
· Range hoods can be heavy to mount, so always ask a friend for help. · Wear protective gloves when handling the range hood and its filters. The edges can be sharp. · For residential use only. Do not install your hood in a restaurant or other commercial environment.
Our hoods do not abide by the rules and regulations for commercial use. · Do not use your hood to vent hazardous or explosive materials and vapors. This is incredibly
dangerous and may result in serious injury. · When cleaning the unit, make sure the power is turned off. · When troubleshooting or replacing the touch panel, circuit board, or other electrical components, turn
power to the range hood off. · Check your local codes and regulations to see what type of ductwork is required, as some codes
require rigid metal ductwork. Avoid using flex duct for your range hood, as it can wear down quickly, cause air to escape into your walls or attic, and create suction issues such as back pressure. · Never vent your ducted hood into an attic, joists in your ceiling, or a soffit. Always vent the hood to the outside to keep grease, smoke, and unwanted contaminants out of your home. · Avoid electrical wiring when drilling a hole into your wall or ceiling for ductwork. · Clean or replace old ductwork with new rigid ductwork to prevent potential grease fires and increase the efficiency of your range hood. · Seal all joints in your duct system with aluminum tape to prevent air from escaping in your walls or attic. · Check your local regulations to determine if you need make-up air, especially if you operate a powerful range hood (600+ CFM) in a small kitchen. When a range hood vents air out of your home, that air has to be replaced. If make-up air is required, it cannot tie into the hood. We do not sell makeup air kits. · Clean your range hood filters, grease trays, and the range hood every few weeks. Heavy grease buildup shortens the life of your hood and it may lead to a grease fire. · All Proline range hoods are ETL certified. They meet all industry standards and regulations to ensure your safety. · Use the high setting on your range hood to vent heavy smoke or heat in case of emergency. Otherwise, use the lower settings to prolong the life of your hood. · While your range hood is on, do not leave your cooking area unattended. · When cooking with oils, do not heat them past their smoke point. If oil starts smoking, turn off the burner and discard any food that came into contact with it. Do not use Extra Virgin Olive Oil in high heat, since it starts to smoke at around 300º Fahrenheit.
4

In the event of a grease fire: · Smother the flames with a large lid, pan, or baking sheet. If the fire is small, smother it with baking soda or salt. For larger fires, use a fire extinguisher. · Turn off all burners. · Do not touch a flaming pan. This may result in serious burns. · Keep all flammable materials away from the grease fire. This may include nail polish remover, flour, rubbing alcohol, and hand sanitizer, among other household items. · Do not pour water on a grease fire. Water will spread the oil around, making the fire more potent and dangerous. Wet towels and rags will also spread the oil, so avoid using these as well. · If you cannot contain the fire, call the fire department immediately.
Warranty Information
· Proline’s Vexair Inline and Local Blowers come with a ten-year warranty. For any issues with your Vexair Blower, please contact Proline.
· If you’re outside the warranty period and your blower is not working properly, call us at (877) 9015530. We typically help fix your Proline range hood at a reasonable price, so you don’t have to replace the whole unit.
Return Policy
· Damage and Defects: Report any damage or defects to Proline within 5 days of receiving your order. · Inspection: Inspect your item upon receipt. Proline will not accept returns on damaged merchandise
after 5 days due to carrier policies. · Damaged Items: If your item is damaged, notify us within the 5-day window for prompt assistance.
Do not install your blower if it is damaged. We will not accept returns on merchandise that has been installed. · Non-damaged Items: Non-damaged items may be returned within 5 days of receipt at no cost to you. After this 5-day window, a restocking fee of 20% of the purchase price will be deducted from your refund. · Returns up to 30 Days: Proline accepts returns up to 30 days after receiving your order. A 20% restocking fee applies from day 6 to day 30. · Returns Beyond 30 Days: Proline will not accept returns after the 30-day period. · Renovation Projects: If purchasing for a renovation project that’s a few months out, remember to inspect your items within 5 days of delivery to ensure they are in good condition. .
5

Proline Inline Blower Installation Guide
4375 W 1980 S, Salt Lake City, UT 84104 Call (877) 901-5530
support@prolinerangehoods.com www.prolinerangehoods.com
Our Support team hours are: Mon-Fri 8:30 am ­ 5:00 pm MST 6

Documents / Resources

PDF thumbnail1300 CFM Inline Blower
Installation Guide · 1300 CFM Inline Blower, 1300 CFM, Inline Blower, Blower

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.