PROJECTA INTELLI-RV GEN II Low Profile 30A PWM Charging System
WARNINGS
- Explosive gases. Prevent flames and sparks. Provide adequate ventilation during charging
- Before charging, read the instructions
- For indoor use. Do not expose to rain
- For charging lead acid and LiFeP04 batteries ONLY (of the size & voltage specified in the specifications table)
- Always charge the battery on the correct voltage setting. Never set the charger to a higher voltage than the battery specifications state
- Disconnect the 240V mains supply before making or breaking the connections to the battery
- Connect the positive battery terminals before making any ground connections. The ground connection to the chassis should be made away from the battery and any fuel line. Only connect mains after the battery is connected
- The battery charger must be plugged into an earthed socket outlet
- Connection to supply mains is to be in accordance with national wiring rules
- Do not attempt to charge non-rechargeable batteries
- Never charge a frozen battery
- If AC cord is damaged, do not attempt to use Replace with a compatible earthed IEC cable immediately.
- Corrosive substances may escape from the battery during charging and damage delicate surfaces Store and charge in a suitable area
- This charger is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible or their safety
- Children being supervised not to play with the appliance
- If the recreational vehicle is to be put into storage without power, please turn off the BATTER MASTER SWITCH. If the recreational vehicle is to be stored for 3 months or longer, it’s advisable to disconnect all fuses from the battery A full charge should be run every 3 months.
2.8 Battery Low voltage protection (BLVP or commonly known as an LVD)
PM335C master power unit has a built-in low voltage protection relay. It will disconnect the load once the battery voltage drops below
the threshold voltage. The default setting is 10.5VDC. This can be manually turned On/Off via the LOAD button on the LCD display
NOTE: Class C3 will remain active as long as the battery switch is left on and Class D loads remain active all the time.
2.9 Battery switch
The PM335C unit Offers a convenient way to switch Off the output Of the service battery on-board. It protects the service battery from
being drained by electronics on board, completely isolating the battery PM335C unit also supports a remote manual battery switch
Before using the remote switch, ensure the manual battery switch at the unit is set as ” ON”
The switch is only effective when the system has no other energy resource for the load except the battery
2.10 Precise Battery Measurement
PM335C unit has a battery measurement system controlled by microprocessor. It measures battery voltage, charge/discharge current,
remaining battery capacity (in amp hours) and time remaining
Compared to conventional indicating meters even small currents can be measured and read accurately with this device. This feature
highlights faults, alarms and installation errors.
NOTE: If you have loads connected directly on the battery instead of PM335C Power Management System, the measurement will not be
accurate.
NOTE: PINO. PMSHUNT will be required for heavy loads designed to be connected direct to battery to ensure SOC% accuracy
2.11 Night Mode
In Night Mode, the backlight ofthe monitor will tum off and the cooling fans will operate at a decreased speed Charge current will be
reduced to half rated selection when night mode is active.6
6.1
Operation
Manual switch
There is an ON/OFF switch on side Of the machine, which is used to contrd the mach’ne to switch on/off when is povvered by
battery ahne, and to contra the whole mach’ne to enter into skep mode when it is powered by mains power This switch must be be “ON”
in Order the Rernote S’,vitch to
6.2 Remote Switch (Optional)
Rem o te
remote switch terminals are hated to positive 14 terminal This requires the use Of an external switch functions
way as the manual On,’Off Battery Switch on the side of the charger. The Battery switch must be “ON” in order to use the Remote Switch line.
When not used both terminab must together
6.3 Dip switch
1234
There is 5 pin dip switch on the unit which is used for adjusting current and battery type. At this time switch 5 is not used and shouh
in the “OFF” position
Note: lhese not to be adjusted a digital screen used6.4 Maintenance
BATTERY MONITOR MAINTENANCE
PM335C SyStgTIS feature buh-in battery software. TO ensure accurate readings maintain the system ‘Nith the folowing
1 : FLU the battery from AC input instead of sdar every 2 weeks
2: FLAW the battery from at East every 3 rrxmths, even in stcrage, ur*ess to earlier.
• Charge battery withAC grid until “CHG ” LED PM335C unit or “Fbat• shows on the monittx
DAILY MAINTENANCE
• Confirm the S’,vitch is ON when you want to charge the battery with AC grid
• battery is 12VDC
• Ensure the Space (SDrnrn each side) beside the PM335C unit for the apptowiate ventlation
• When replacing and battery, fuly charge via AC grid to Fbat to ensure SOC% is accurat4y caibrated.
Note: If the house battery is allov.•ed to &ained to a point cannot power the system, the house battery must charged to float
mcxie via AC maims to recalibrate the internal I external shunt. Falure to do so yield an inaccurate SOC% (State of Charge 0/0),
causing premature shutdown when off-grid as the system sees tip battery as a Connection’ and gives an assumed, not accurate
SOC ‘Aue based on battey voltage.
Only the energy consumption of the loads connected on the PM335C is and cdcdated
in the data the Monit0G Unless a shunt is fitted. projecta pln PMSHUNT
For it is recanmended to switch Off the Manual Battery Switch on the unit or the
Documents / Resources
![]() |
PROJECTA INTELLI-RV GEN II Low Profile 30A PWM Charging System [pdf] Instruction Manual INTELLI-RV, INTELLI-RV GEN II Low Profile 30A PWM Charging System, GEN II Low Profile 30A PWM Charging System, Low Profile 30A PWM Charging System, 30A PWM Charging System, Charging System |