PEPPERL plus FUCHS LVL-A7-AG1A-E5V1-CG-EMS Vibration Limit Switch

PEPPERL plus FUCHS LVL-A7-AG1A-E5V1-CG-EMS Vibration Limit Switch

Function

The Vibracon LVL-A7 is a limit switch for liquids and is used in tanks, vessels and pipes. The device is used for overfill prevention or pump protection in cleaning and filter systems as well as in cooling and lubrication vessels, for instance.
The device is suitable for applications in which float switches or conductive, capacitance and optical sensors have been used up to now. The device also works in areas where these measuring principles are not suitable due to conductivity, buildup, turbulence, flow conditions or air bubbles.
The device can be used for process temperatures up to 100 °C (212 °F).
The device is not suitable for use in hazardous areas.
For hygienic areas we recommend the use of Vibracon LVL A7H.

Connection

Connection

Dimensions

Dimensions

Technical Data

General specifications

Measuring method

  The tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid.
Construction type   compact device
Operating mode   MAX = maximum safety:

The device keeps the electronic switch closed as long as the liquid level is below the fork.

example application: overspill protection MIN = minimum safety:

The device keeps the electronic switch closed as long as the fork is immersed in liquid. example application: dry running protection of pumps

The electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle)

Series   LVL-A*
Supply
Connection   This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.
Rated voltage Ur 10 … 35 V DC
Fusing   external 500 mA slow
Current consumption   < 15 mA
Power consumption   975 mW
Residual ripple

Input

Measured variable

  5 V ss at 0 … 400 Hz

density

Measurement range   min. 0.7 g/cm3
Output
Output type   switching output
Switching current

Directive conformity

Electromagnetic compatibility

  max. 250 mA
Directive 2014/30/EU   EN 61326-1:2006 , EN 61326-2-3:2006
Directive 2004/108/EC

Conformity

Electromagnetic compatibility

  EN 61326-1:2006 , EN 61326-2-3:2006

NE 21

Degree of protection   IEC 60529
Shock resistance   EN 60068-2-27
Vibration resistance   EN 60068-2-64
Climate class

Measurement accuracy

Reference operating conditions

  DIN EN 60068-2-38/IEC 68-2-38

 

–  ambient temperature: 25 °C (+77 °F)

–  process pressure: 1 bar (14.5 psi)

–  fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s)

–  medium temperature: 25 °C (+77 °F)

–  density setting: > 0.7 g/cm3

–  switching time delay: standard (0,5 s, 1 s)

Measured value resolution   < 0.5 mm
Measuring frequency   approx. 1100 Hz in air
Switching point   13 mm ± 1 mm
Non-repeatability   ± 1 mm acc. to DIN 61298-2
Hysteresis   max. 3 mm
Influence of ambient temperature   negligible
Influence of medium temperature   -25 µm/°C
Influence of medium pressure   -20 µm/bar
Switching time   –  0.5 s when tuning fork is covered

–  1.0 s when tuning fork is uncovered

Switch-on delay

Operating conditions

Installation conditions

  max. 3 s
Installation position                                          see technical information (TI)
Ambient conditions
Ambient temperature -40 … 70 °C (-40 … 158 °F)
Storage temperature -40 … 85 °C (-40 … 185 °F)
Shock resistance a = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea
Vibration resistance a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h
Process conditions
Medium temperature -40 … 100 °C (-40 … 212 °F)
Process pressure (static pressure) -1 … +40 bar (-14.5 … +580 psi)
State of aggregation liquid
Density min. 0.7 g/cm3
Viscosity 1 … 10000 mPa/s, dynamic viscosity
Solid contents < ∅5 mm
Mechanical specifications
Degree of protection IP65/IP67 , NEMA 4X
Connection M12 connector, 4-pin
Material process connection and short tube: stainless steel 316L (1.4401/1.4435) tuning fork: stainless steel 316L housing cover and connector: PPSU
Surface quality Ra < 3.2 µm
Mass approx. 140 g
Process connection Indication and operation Display elements thread G1/2 to ISO 228

The LED display is on the connection side.

–  green LED: indication of ready to operate

–  red LED: fault indication

–  yellow LED: operating mode indication

Function test function test with test magnet (optional accessory)
Certificates and approvals
CSA approval cCSAus Listed, General Purpose
Overspill protection

General information

Supplementary documentation

see approval (ZE)

technical information (TI) manual (BA)

approval (ZE)

Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl- fuchs.com.
Accessories
Designation see technical information (TI)

Customer Support

Pepperl+Fuchs Group
www.pepperl-fuchs.com

USA: +1 330 486 0002
pa-info@us.pepperl-fuchs.com

Symbols

Logo

Documents / Resources

PEPPERL plus FUCHS LVL-A7-AG1A-E5V1-CG-EMS Vibration Limit Switch [pdf] Owner's Manual
275573-100021, LVL-A7-AG1A-E5V1-CG-EMS Vibration Limit Switch, LVL-A7-AG1A-E5V1-CG-EMS, Vibration Limit Switch, Limit Switch, Switch

References