Instruments PCE-SFS 10 Gauss Meter
User Manual
User manuals in various languages
Product search on: www.pce-instruments.com
Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
- The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
- The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
- Do not expose the device to shocks or strong vibrations.
- The case should only be opened by qualified PCE Instruments personnel.
- Never use the instrument when your hands are wet.
- You must not make any technical changes to the device.
- The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
- The device must only be used with accessories from PCE Instruments or equivalent.
- Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
- Do not use the instrument in explosive atmospheres.
- The measurement range as stated in the specifications must not be exceeded under any circumstances.
- Non-observance of the safety notes can cause damage to the device and injuries to the user.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of business.
If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.
Specifications
Electromagnetic field | |
Measurement range | ±60 kV DC |
Resolution | ±20 kV DC: 0.01 kV DC -60 … -20 kV DC / +20 … +60 kV DC: 0.1 kV DC |
Accuracy | ±5 % of reading |
Temperature | |
Measurement range | -40…. 123.8 °C |
Resolution | 0.1 °C |
Accuracy | ±1.5 °C |
Humidity | |
Measurement range | 0 … 100 % RH |
Resolution | 0.1 % RH |
Accuracy | ±4.5 % RH |
Further specifications | |
Response time | <100 ms |
Audible alarm | when the meter is switched on, 5 seconds before automatic power off, when measurement range is exceeded |
Automatic power off | after 5 minutes |
Power supply | 9 V block battery |
Operating time | >20 hours |
Operating conditions | 0 … 40 °C, 0 … 60 % RH, non-condensing |
Dimensions | 123 x 70.4 x 21.5 mm |
Weight | 147 g |
Delivery scope
- 1 x gauss meter PCE-SFS 10
- 1 x earthing cable
- 1 x carrying bag
- 1 x 9 V block battery
- 1 x user manual
Device description
No. | Description |
1 | Housing |
2 | Display |
3 | On and off switch |
4 | HOLD key to freeze the display |
5 | ECO key for switching the backlight on and off |
6 | Status display |
No. | Description |
7 | Temperature and humidity sensor |
8 | Service interface |
9 | Alignment laser |
10 | Radiation sensor |
No. | Description |
11 | Zero key for setting the zero point |
12 | Earth connection |
13 | Nameplate |
14 | Battery compartment |
4.1 Display description
No. | Description |
1 | Polarity of the magnetic field |
2 | Temperature display |
3 | Humidity display |
4 | Measured value |
5 | Battery status display |
6 | “HOLD” – display is frozen |
Battery information
The battery life is a maximum of 20 hours. The battery status is continuously shown on the display.
Battery status display | Meaning |
![]() |
Battery is fully charged. |
![]() |
Battery is partially discharged. |
![]() |
Battery almost discharged. The battery should be replaced promptly. |
![]() |
Battery is discharged. The battery must be replaced for further use. |
To replace the battery, first switch off the meter and remove the earthing cable from the meter. Then open the battery compartment and replace the battery with a new 9 V block battery. Then close the battery compartment. The measurement can be resumed.
Switching on and off
To switch the meter on and off, press the on/off switch. The measurement is made after a few seconds. To switch the meter off again, press the on/off switch again.
Backlight
When the meter is switched on, the backlight is activated. To switch off the backlight, press and hold the “ECO” key for two seconds. To switch the backlight back on, press and hold the “ECO” key again for two seconds.
Making a measurement
To make a measurement, first connect the earthing cable to the meter and to an earthed conductor. Then switch on the meter. The measurement will start after a short time. Point the measuring device at the object to be measured. You have reached the correct distance as soon as the lasers cross. Now you can read the measured value.
Zeroing
To zero the meter, first ground it with the earthing cable. Then switch on the meter and wait until the reading has stabilized. Then press the zero key to set the displayed reading to zero.
NOTE: Make sure that there is no static charge on the sensor side. This can influence zeroing.
Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either reuse them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
PCE Instruments contact information
Germany PCE Deutschland GmbH Im Langel 26 D-59872 Meschede Deutschland Tel.: +49 (0) 2903 976 99 0 Fax: +49 (0) 2903 976 99 29 info@pce-instruments.com www.pce-instruments.com/deutsch |
United Kingdom PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign Way, Southampton Hampshire United Kingdom, SO31 4RF Tel: +44 (0) 2380 98703 0 Fax: +44 (0) 2380 98703 9 info@pce-instruments.co.uk www.pce-instruments.com/english |
The Netherlands PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede Nederland Telefoon: +31 (0)53 737 01 92 info@pcebenelux.nl www.pce-instruments.com/dutch |
France PCE Instruments France EURL 23, rue de Strasbourg 67250 Soultz-Sous-Forets France Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 info@pce-france.fr www.pce-instruments.com/french |
Italy PCE Italia s.r.l. Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano Capannori (Lucca) Italia Telefono: +39 0583 975 114 Fax: +39 0583 974 824 info@pce-italia.it www.pce-instruments.com/italiano |
United States of America PCE Americas Inc. 1201 Jupiter Park Drive, Suite 8 Jupiter / Palm Beach 33458 FL USA Tel: +1 561-320-9162 Fax: +1 561-320-9176 info@pce-americas.com www.pce-instruments.com/us |
Spain PCE Ibérica S.L. Calle Mayor, 53 02500 Tobarra (Albacete) España Tel. : +34 967 543 548 Fax: +34 967 543 542 info@pce-iberica.es www.pce-instruments.com/espanol |
Turkey PCE Teknik Cihazları Ltd.Şti. Halkalı Merkez Mah. Pehlivan Sok. No.6/C 34303 Küçükçekmece – İstanbul Türkiye Tel: 0212 471 11 47 Faks: 0212 705 53 93 info@pce-cihazlari.com.tr www.pce-instruments.com/turkish |
© PCE Instruments
Last change: 29 December 2021
v1.0
Documents / Resources
![]() |