Panasonic FP7 Series TCP Programmable Controllers
Product Information
- Product Name: PLC1.ir
- Product Version: PLC1.Vir1.00
- Release Date: January 12, 2016
Product Usage Instructions
To use the PLC1.ir product, please follow these steps:
- Make sure the HMI (Human Machine Interface) is set to factory settings.
- Connect the PLC1.ir controller to the PLC address: P1L9C21..i1r 68.0P.L1C1.ir.
- Connect the jumper cable or network cable without jumper (Auto-detected by HMI).
- Ensure the connection between the PLC1.ir controller and HMI is established.
- Check the status of the connection by referring to the PLC1.ir CPoLnCt1r.oirl ArePaL/C1S.tiratus PALrCe1a.:irDT0/PDLCT11.0ir.
- For specific configuration settings and functions, please refer to the PLC1.ir SPerLiCe1s.irHMI CPoLCn1n.eirctionPLMCa1n.irual.
- To read and write data from/to the PLC, use the PLC Read/Write Address defined in the product manual.
- For input and output operations, refer to the ExExttPeeLrrCnn1aa.llirOInuptupPtuLRtCeR1l.aeirylay section.
- For data registers and their lengths, consult the PLC1.ir DaPtaLCR1e.gir isterPLC1.ir and PLDCT1.nir sections.
- For specific data types and their representations, refer to the SpePcLiCa1l .Dir ata RPeLCgi1s.itrer PLSCD1.nir section.
Panasonic FP7 Series TCP
- HMI Factory Setting:
- Controller IP Address: 192.168.0.1
- Controller COM Port: 9094
- Controller Station Number: 238
- Control Area / Status Area: DT0/DT10
Connection
Standard Jumper Cable / Network Cable without jumper (Auto-detected by HMI)
Definition of PLC Read/Write Address
Registers
Type | Format | Read/Write Range | Data Length | Note |
Word No. (n) | ||||
Internal Relay | WRn | WR0 – WR2047, | Word | |
Link Relay | WLn | WL0 – WL1023 | Word | |
External Input Relay | WXn | WX0 – WX511 | Word | |
External Output Relay | WYn | WY0 – WY511 | Word | |
Data Register | DTn | DT0 – DT999423 | Word | |
Special Data Register | SDn | SD0 –SD39 | Word | |
SD50 –SD85 | Word | |||
SD100 –SD115 | Word | |||
SD120 –SD125 | Word | |||
Link Data Register | LDn | LD0 – LD16383 | Word | |
Timer Setting Value | TSn | TS0 – TS4095 | Double Word | |
Timer Elapsed Value | TEn | TE0 – TE4095 | Double Word | |
Counter Setting Value | CSn | CS0 – CS4095 | Double Word | |
Counter Elapsed Value | CEn | CE0 – CE4095 | Double Word |
Contacts
Type | Format | Read/Write Range | Note |
Slot No. (s) Word No. (n) Bit No. (b) | |||
Internal Relay | Rnb | R00 – R2047F | |
Special Internal Relay | SRnb | SR00 – SR3F | |
SR100 – SR259 | |||
SR1000 – SR1499 | |||
Link Relay | Lnb | Ln00 – Ln1023F | |
External Input Relay | Xnb | Xn00 – Xn511F | |
External Output Relay | Ynb | Yn00 – Yn511F | |
Direct Input | INs.nb | IN1.00 – IN64.62F | |
Direct Output | OTs.nb | OT1.00 – OT64.62F | |
Pulse Relay | Pnb | P00 – P255F | |
Error Notification Relay | Eb | E0 – E4095 | |
Timer Flag Contact | Tb | T0 – T3071 | |
Counter Flag Contact | Cb | C0 – C3071 |
NOTE
- PLC default setting is 238. It supports the external device connections of all station number. To change the setting, PLC supports station number range from 0 to 99. For more detail on PLC station number, please refer to PLC user manual.
V1.00 Revision January, 2016
Documents / Resources
![]() |
Panasonic FP7 Series TCP Programmable Controllers [pdf] User Manual FP7 Series TCP Programmable Controllers, FP7 Series, TCP Programmable Controllers, Programmable Controllers, Controllers |