Installation Instructions

There are two installation ways, choose one or both.
First Way – Install with Screws
Step1. Open Cover
You can use any tool to open the cover from the bottom of the door sensor.

Pamex KP1 DS Kapture Door Sensor- Open Cover

First Way – Install with Screws
Step2. Mark and drill hole location
Use the sensor/magnet mounting part to mark and drill the mounting holes.

Pamex KP1 DS Kapture Door Sensor- drill hole location

Notice
Please make sure the object thickness is no less than 1-1/4”.

Pamex KP1 DS Kapture Door Sensor- Side View

Step3. Installation
After installing the screws, close the cover.
Note that not only the wall, you can also install it wherever you need it, such as a window, door…etc.

Pamex KP1 DS Kapture Door Sensor- Install with Screws

Second Way – Install with Stickers
Step1. Installation
Only use stickers to fix the door sensor.
Note that not only the wall, you can also install it wherever you need it, such as a window, door…etc.

Pamex KP1 DS Kapture Door Sensor- Install with Stickers

Light Indicator Chart

Door Sensor Away – Flash 1 Red LED Pamex KP1 DS Kapture Door Sensor- Red LED

Pamex KP1 DS Kapture Door Sensor- Light Indicator Chart

Door Sensor Connect – Flash 1 Green LED Pamex KP1 DS Kapture Door Sensor- Green LED
Effective distance is less than 1-1/2″.

Pamex KP1 DS Kapture Door Sensor- Door Sensor Connect

FCC Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions :

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installedand used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures :
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and a human body.

Documents / Resources

Pamex KP1-DS Kapture Door Sensor [pdf] Installation Guide
KP1DS, 2AQ8A-KP1DS, 2AQ8AKP1DS, KP1-DS Kapture Door Sensor, Kapture Door Sensor, Door Sensor, Sensor

References

Leave a comment

Your email address will not be published. Required fields are marked *