OSS-KIT-logo

OSS-KIT-EXP-6002 Host Server to Expansion System Kit

OSS-KIT-EXP-6002 Host Server to Expansion System Kit-fig1

Overview

Description
The PCIe x4 expansion kit is used to extend the PCI express bus from a host server to an external expansion chassis. The host adapter card inserts into a PCIe slot of the server. It then cables to a downstream expansion link board (ELB). The ELB acts as a downstream cable link board and the primary fan-out switch to support multiple configurations of PCI express expansion slots. The host adapter installs into a PCIe x4, x8 or x16 slot on the host motherboard. It then cables to the expansion link board and installs in the SHB or system slot of a CPCIe backplane.

OSS-KIT-EXP-6002 Host Server to Expansion System Kit-fig2

Features

Adapter Cards

  • The Host adapter card inserts into any PCI Express x4, x8, 16 slot on the host motherboard.
  • The Target adapter card fits into SHN slot of PICMG 1.3 backplane..
  • Support half-height bracket.
  • The Host and Target cable adapter cards require no software / drivers

x4 Link Cable

  • Available in 1m, 2m, 3m, 5m, 7m lengths.
  • PCI-SIG Express Cable Specification Compliant.
  • Includes x4 PCIe lane and side-band signals for:
    • Power ON
    • Reset
    • PCIe clock
    • Cable Present
    • Wake
  • Positive latching mechanism per PCI-SIG specification
  • Support 10 Gbps full-duplex transfer rates.

Specifications

Host Adapter

PCIe x4 Host Cable Adapter Card (SKU : OSS-PCIe-HIB25-X4-H)
Form Factor PCIe x4 add-in card
Dimension (H x L) 2.7” x 3.1” (68 x 78mm)
Front Panel Connectors One PCIe x4 cable connectors
Front Panel Indicators Power ON / Cable Present LED
Red-drivers Pericom P12EQX5804
Temperature Range 0° to 50°C (32° to 122°F)
Relative Humidity 10 to 90% non-condensing
Shock 30g Acceleration peak (11 ms pulse)
Vibration 5-17 Hz 0.5” double amplitude displacement; 7-2000Hz, 1.5g acceleration
Power Consumption 3.75W typical, 3.3@1.3A
Agency Compliance UL60950, FCC Class B, CE safety and emissions, ROHS
Redriver Pericom P12EQX5804

Expansion Link Board

PCIe x4/x8 Gen2 Expansion Link Board (SKU : OSS-SHB-G2-x8-x4)
Form Factor PCIMG EXP.system slot compliant. Single Slot
Slot Type System slot for the expansion chassis
Dimension (H x L) 3.937 x 6.299 in (100 x 160 mm), 1 slot wide
Switch PLX PEX8733 32 lane switch
Upstream Interface x4 PCI Express over cable

PCI-SIG PCI Express Cable Rev 2.0 Compliant

 

 

Downstream Interface

16 lanes of PCI Express on the backplane connectors.

The lanes form two or four links to the backplane through the XP2 and XP3 connectors per the PICMG EXP.0 specification.

The following link modes are automatically selected by the backplane as follows:

•  Two link mode: 2 x8 links (per backplane capabilities)

•  Four link mode: Four x4 PCIe links

Front Panel Connectors 1 PCIe x4 Cable (Molex : 75586-0010)
Front Panel Indicators 4 backplane link-active indicators (green)

2 or 4 link mode + cable link (green)

Power Consumption 10W typical +12V @ .5, 3.3V @ 1.25A, 5Vaux @ 2.5mA
Temperature Range 0° to 50°C (32° to 122°F)
Relative Humidity 10 to 90% non-condensing
Storage Temperature -40° to 85°C (-40°-185°F)
Shock 30g acceleration peak (11ms pulse)
Vibration 5-17 Hz 0.5” double amplitude displacement; 7-2000Hz, 1.5g acceleration
Agency Compliance UL60950, FCC Class B, CE safety and emissions, ROHS

PCIe x4 Cable

PCIe x4 Cable (SKU : OSS-PCIe-CBL-x4.1M) 1 meter long cable
Cable Length 1m, 2m, 3m, 5m, 7m
Circuits loaded 38
Gender Male-to-Male
Lock to Mating Part Yes
Material-Metal Zinc Alloy
Pitch-Mating Interface 0.80mm (0.31)
Single Ended No
Water proof / Dust

proof

Yes
Wire Insulator

Diameter

N/A
Wire Size AWG 28
Wire / Cable Type Round
Electrical Current 1A Max per contact
Shielded Yes
Voltage-Maximum 30V DC

Component Identification

Host cable adapter card
The PCIe x4 expansion kit contains two cable adapter boards, the host cable adapter and the target cable adapter. The host adapter inserts into the host computer’s PCIe x4, x8 or x16 slot.

OSS-KIT-EXP-6002 Host Server to Expansion System Kit-fig3

Cable LED indicators are the same for both Host and Target configurations.

Expansion Link Board
The Expansion Link Board (ELB) OSS-CPCIe3-3U/6U-ELB-x4 is a downstream link board that installs into a CPCIe chassis. The ELB fits into the system slot of a CPCIe backplane. The ELB is the downstream link board and the primary fan-out switch to support multiple configurations of CPCI or CPCIe expansion slots.

OSS-KIT-EXP-6002 Host Server to Expansion System Kit-fig4

Installation Instructions

Installing the Adapter Kit
Insert the host cable adapter into an appropriate PCIe slot of the host computer. For example, a PCIe x4 host board can be inserted into a PCIe x16, x8, or x4 slot. It will still operate at x4 speeds. Secure the cable adapter card

Expansion link board

  1. Insert the expansion link board into the SHB slot on the chosen backplane.
  2. Connect the x4 PCIe cable to both cables adapter cards. Press or pull the green TAB while slowly inserting the cable, then release it to lock the cable. See photos belowOSS-KIT-EXP-6002 Host Server to Expansion System Kit-fig5
  3. Test by pulling back on the connector.

Removing PCIe Cable
To remove the cable, press or pull the green tab and slowly pull the cable out.

Operation

  1. Plug in expansion system and turn the power supply on.
  2. Power up host computer.
  3. The expansion system will power up.

Technical Information

The transmit and receive signals on the OSS-HIB-25×4 are driven and conditioned by Pericom redriver chips. Adjustments can be made to equalization, de-emphasis and output swing. These controls are factory set by the use of zero Ohm resistors.
In the following tables, a 0 indicates that a zero Ohm resistor has been installed and a 1 indicates no resistor. In rare cases, mostly where non-OSS equipment is used with the HIB-25×4, these adjustments may need to be changed. The following tables are made available for this purpose. It is highly recommended to contact OSS customer support before making changes to these settings. Having the customer solder to the board should void the warranty.

Signal Adjustment

OSS-KIT-EXP-6002 Host Server to Expansion System Kit-fig7

Pin Assignments
Host and Target card connectors (x4 Card Edge Connector)

  • The pins are numbered as shown with side A on the top of the centerline on the solder side of the board and side B on the bottom of the centerline on the component side of the board.
  • The PCIe interface pins PETpx, PETnx, PERpx, and PERnx are named with the following convention: “PE” stands for PCIe high speed, “T” for Transmitter, “R” for Receiver, “p” for positive (+), and “n” for negative (-).
  • Note that adjacent differential pairs are separated by two ground pins to manage the connector crosstalk.

Pin-out for the PCIe x4 Card Edge Connector on the “Host Cable Adapter”

 

 

 

Pin #

 

Side B

 

Side A

 

Name

 

Description

 

Name

 

Description

1 N/C N/C PRSNT1# Hot-Plug presence detect
2 N/C N/C N/C N/C
3 N/C N/C N/C N/C
4 GND Ground GND Ground
5 NC N/C N/C Not connected
6 N/C N/C JTAG3 TDI (Test Data Input)
7 GND Ground JTAG4 TDO (Test Data Output)
8 +3.3V 3.3 V power N/C Not connected
9 N/C Not connected N/C Not connected
10 3.3Vaux 3.3 V auxiliary power +3.3V 3.3 V power
11 N/C N/C PERST# Fundamental reset
Mechanical key
12 RSVD Reserved GND Ground
13 GND Ground REFCLK+ Reference clock (differential pair)
14 PETp0 Transmitter differential pair, Lane 0 REFCLK
15 PETn0 GND Ground
16 GND Ground PERp0 Receiver differential pair, Lane 0
17 PRSNT2# Hot-Plug presence detect PERn0
18 GND Ground GND Ground
19 PETp1 Transmitter differential pair, Lane 1 RSVD Reserved
20 PETn1 GND Ground
21 GND Ground PERp1 Receiver differential pair, Lane 1
22 GND Ground PERn1
23 PETp2 Transmitter differential pair, Lane 2 GND Ground
24 PETn2 GND Ground
25 GND Ground PERp2 Receiver differential pair, Lane 2
26 GND Ground PERn2
27 PETp3 Transmitter differential pair, Lane 3 GND Ground
28 PETn3 GND Ground
29 GND Ground PERp3 Receiver differential pair, Lane 3
30 RSVD Reserved PERn3
31 PRSNT2# Hot-Plug presence detect GND Ground
32 GND Ground RSVD Reserved

Notes:

  1. Optional signals that are not implemented are left as no connects on the board side connector.
  2.  Reserved signals are no connects on the board side connector.
  3.  Although support of CWAKE# is optional from the board side connector perspective, an allocated wire is mandated for the cable assembly.
  4. Board side pin-outs on both sides of the Link are identical. The cable assembly incorporates a null modem for the PCIe transmit and Board side pin-outs on both sides of the Link are identical. The cable assembly incorporates a null modem for the PCIe transmit and

PCI Express x4 Connector PIN Assignment

OSS-KIT-EXP-6002 Host Server to Expansion System Kit-fig6

Pin-out for the PCIe x4 Cable

Pin # Cable Side 1   Cable Side 2 Pin #
A1 A4 A7 A10 A13 A16 B1 B4 B7 B10 B13 GND Drain Wires GND A1 A4 A7 A10 A13 A16 B1 B4 B7 B10 B13
A2 PETp0 Differential Pair PERp0 B2
A3 PETn0 PERn0 B3
A5 PETp1 Differential Pair PERp1 B5
A6 PETn1 PERn1 B6
Pin # Cable Side 1   Cable Side 2 Pin #
A8 PETp2 Differential Pair PERp2 B8
A9 PETn2 PERn2 B9
A11 PETp3 Differential Pair PERp3 B11
A12 PETn3 PERn3 B12
A14 CREFCLK+ Differential Pair CREFCLK+ A14
A15 CREFCLK CREFCLK- A15
A17 SB_RTN Hook-up Wire SB_RTN A17
A18 CPRSNT# Hook-up Wire CPRSNT# A18
A19 CPWRON Hook-up Wire CPWRON A19
B2 PERp0 Differential Pair PETp0 A2
B3 PERn0 PETn0 A3
B5 PERp1 Differential Pair PETp1 A5
B6 PERn1 PETn1 A6
B8 PERp2 Differential Pair PETp2 A8
B9 PERn2 PETn2 A9
B11 PERp3 Differential Pair PETp3 A11
B12 PERn3 PETn3 A12
B14 PWR NC PWR B14
B15 PWR NC PWR B15
B16 PWR_RTN NC PWR_RTN B16
B17 PWR_RTN NC PWR_RTN B17
B18 CWAKE# Hook-up Wire CWAKE# B18
B19 CPERST# Hook-up Wire CPERST# B19
Back shell Chassis Ground Overall Cable Braid Chassis Ground Back shell

Signal Descriptions

PETp(x) PCI Express Transmit Positive signal of (x) pair.
PETn(x) PCI Express Transmit Negative signal of (x) pair.
PERp(x) PCI Express Receive Positive signal of (x) pair.
PERn(x) PCI Express Receive Negative signal of (x) pair.
CREFCLK+/- Cable REFerence CLocK: Provides a reference clock from the host system to the remote system.
SB_RTN Side Band ReTurN: return path for single ended signals from remote systems.
CPRSNT# Cable PReSeNT: Indicates the presence of a device beyond the cable.
PWR PoWeR: Provides local power for in-cable redriver circuits. Only needed on long cables. Power does not go

across the cable.)

PWR_RTN PoWeR ReTurN: Provides local power return path for PWR pins.
CWAKE# Cable WAKE
CPERST# Cable PCI Express Reset

Connector Pin-outs for the PCIe x4 Cable Connector

PIN# SIGNAL DESCRIPTION
A1 GND Ground reference
A2 PETp0 Differential PCI Express Transmitter Lane 0
A3 PETn0
A4 GND Ground reference
A5 PETp1 Differential PCI Express Transmitter Lane 1
A6 PETn1
A7 GND Ground reference
A8 PETp2 Differential PCI Express Transmitter Lane 2
A9 PETn2
A10 GND Ground reference
A11 PETp3 Differential PCI Express Transmitter Lane 3
A12 PETn3
A13 GND Ground reference
A14 CREFCLK+ Differential 100MHz cable reference clock
A15 CREFCLK-
A16 GND Ground reference
A17 SB_RTN Side Band Return
A18 CPRSNT# Used for detection of external cable and if downstream system is powered
A19 CPWRON Turns power on / off to slave type downstream subsystems
B1 GND Ground reference
B2 PERp0 Differential PCI Express Receiver Lane 0
B3 PERn0
B4 GND Ground reference
B5 PERp1 Differential PCI Express Receiver Lane 1
B6 PERn1
B7 GND Ground reference
B8 PERp2 Differential PCI Express Receiver Lane 2
B9 PERn2
B10 GND Ground reference
B11 PERp3 Differential PCI Express Receiver Lane 3
B12 PERn3
B13 GND Ground reference
B14 PWR +3.3V Cable Power
B15 PWR
B16 PWR_RTN Cable Power Return
B17 PWR_RTN  
B18 CWAKE# Power management signal for wakeup events (optional)
B18 CPERST# Cable Reset#

PCI Express x4 Connector PIN Assignment

CFG(0:2) BP PORT CFG
0 1 2 A0 A1 A2 A3 B0
0 0 0 X4 X4 X4 X4 X4
0 1 0 X8 0 X4 X4 X4
0 1 1 X8 0 X8 0 X4
1 X X X16 0 0 0 X4

Contacting Technical Support

Our support department can be by phone at 1 760-745-9883. Support is available Monday through Friday, 8:00 AM to 5:00 PM PT. When contacting One Stop Systems Technical Support, please be sure to include the following information:

  1. Name
  2. Company Name
  3. Phone Number
  4. Fax Number
  5. Email Address
  6. Model Number
  7. Serial Number
  8. Computer Make
  9. Computer Model
  10.  Operating System and Version
  11.  Make/Model of PCI cards in expansion chassis
  12. Detailed description of the problem

You can also visit our web site at: www.onestopsystems/support/ 

For a quick response, use the Technical Support and RMA Request Form available in the Support Section of the website. Simply complete the form with all required information. Please make sure that your problem description is sufficiently detailed to help us understand your problem.
For example: Don’t say “Won’t boot up.” Do say “Tried all the steps in the Troubleshooting Section and it still won’t boot up.”
For faster diagnosis of your problem, please run the two utility programs described in the following sections and include the diagnostic files they generate with your email.

Returning Merchandise to One Stop Systems

If factory service is required, you must contact OSS Service Representative to obtain a Return Merchandise Authorization (RMA) number. Put this number and your return address on the shipping label when you return the item(s) for service. One Stop Systems will return any product that is not accompanied by an RMA number. Please note that One Stop Systems WILL NOT accept COD packages, so be sure to return the product freight and duties-paid.
Ship the well-packaged product to the address below:
RMA # ________
One Stop Systems
2235 Enterprise Street, Suite#110 92029
USA

It is not required, though highly recommended, that you keep the packaging from the original shipment of your One Stop Systems product. However, if you return a product to One Stop Systems for warranty repair/ replacement or take advantage of the 30-day money back guarantee, you will need to package the product in a manner similar to the manner in which it was received from our plant. One Stop Systems cannot be responsible for any physical damage to the product or component pieces of the product (such as the host or expansion interfaces for the PCIe expansion chassis) that are damaged due to inadequate packing. Physical damage sustained in such a situation will be repaired at the owner’s expense in accordance with Out of Warranty Procedures. Please, protect your investment, a bit more padding in a good box will go a long way to insuring the device is returned to use in the same condition you shipped it in. Please call for an RMA number first.

2235 Enterprise Street, Suite#110, Escondido CA 92029
Toll-Free (80) 285-8990 US Main 858-530-2511 Fax 858-530-2733
www.onestopsystems.com

Documents / Resources

OSS OSS-KIT-EXP-6002 Host Server to Expansion System Kit [pdf] User Manual
OSS-KIT-EXP-6002 Host Server to Expansion System Kit, OSS-KIT-EXP-6002, Host Server to Expansion System Kit, Host Server, Expansion System Kit, System Kit

References

Leave a comment

Your email address will not be published. Required fields are marked *