Omni Ultimate
User Manual
www.omnicharge.co
POWER YOUR NEXT ADVENTURE
For more information visit our support page at www.omnicharge.co
WARNING
SAFETY AND HANDLING
Read all instructions and cautions carefully before use to avoid personal injury or damage to the unit and any connected products
- Handling
Set up your Omnicharge on a hard, stable work surface which allows for adequate air ventilation around the power bank. Omnicharge can be damaged if dropped, burned, punctured, crushed, exposed to heat or moisture or if it comes in contact with liquid. Do not use a damaged Omnicharge as it may cause injury. - Shock or Fire Hazard
This Omnicharge generates the same potentially lethal AC power as a normal household wall outlet. Please use it carefully just like using a normal AC wall outlet. DO NOT insert foreign objects into outputs or ventilation holes - DC Output
Improper use of DC Output may harm your device. Consult with your device manufacturer to check the designated voltage before use. - Recycling
The battery in your device should be serviced or recycled by an authorized service provider and must be recycled or disposed of separately from household waste. Dispose of batteries according to your local environmental laws and guidelines. If no laws or regulations govern, dispose of your omnicharge in a waste bin for electronics. - Recharging
The Omnicharge needs to be recharged within 7 days of purchase and every 6 months to maintain optimal battery health. Failure to do this can cause the battery to over-deplete and will not be covered by warranty.
Any manipulation to the unit or its components will void all warranties
BEFORE USING
Calibrate the battery
To make sure the battery reading is correct, please calibrate the Omnicharge battery when you first receive the product and periodically in the future.
It’s easy to do. Follow these steps:
- Fully discharge Omnicharge until the screen turns off. Press the Power Button and you should see an empty battery icon on the screen.
- Fully charge your Omnicharge to 100% to finish the calibration.
Note: The Omnicharge battery needs to be recharged at least every 6 months to avoid over depletion. Failure to do so can cause the battery to malfunction and is not covered by warranty.
1. Power and Menu Button | 5. DC Input Port |
2. AC Outlet Button/Move Up | 6. USB-A Ports |
3. DC Outlet Button/ Move Down | 7. USB-C Input / Output Por |
4. AC Outlet | 8. DC Output Port |
![]() |
• Long press to power on • Quick press to turn screen display on/off |
![]() |
• On/Off AC outlet • Quick press DC out settings • Long press to output the last set output value directly |
![]() |
• Double press to enter the menu • Quick press to select |
![]() |
• Move Up • Move Down |
SCREEN
OLED screen with real-time metrics
1. Status Icons | 4. Battery Temperature |
2. Total Input Wattage | 5. USB-C/Barrel DC Output Voltage |
3. Total Output Wattage from the Battery | 6. Battery Percentage Remaining |
SCREEN ICONS
![]() |
AC OUTPUT AC outlet is activated |
![]() |
OVERPOWER PROTECTION Device is drawing too much power. Omnicharge will limit or cut off the output power. |
![]() |
USB OUTPUT USB ports are turned on. |
![]() |
OVERHEATING PROTECTION Battery temperature is too high. Omnicharge will limit or cut off its input and output power. |
![]() |
USB-C OUTPUT 60W USB-C output is activate |
![]() |
OVERVOLTAGE PROTECTION Barrel input voltage exceeds the 32V limit. Input charging circuit is shut off. |
![]() |
ADJUSTABLE DC OUTPUT Adjustable 5V-60V DC output is activated. |
![]() |
CHARGING INPUT Your Omnicharge is being charged. |
![]() |
LOW-TEMPERATURE PROTECTION The battery’s temperature is too low and the charging circuit is shut off. |
![]() |
OPTIMAL CHARGING Charging at maximum power. |
![]() |
LOW POWER PROTECTION (ONLY DURING PASS-THROUGH) Occurs when outgoing power is higher than incoming power and battery is empty. Omnicharge will cut off the outgoing power until a sufficient battery level has been reached. |
![]() |
SOLAR CHARGING Charging from solar power. |
MENU NAVIGATION
![]() |
While the screen is on double press the power button to enter the menu |
![]() |
When in the menu, navigate up and down using the buttons on the right of the screen. Use the power button to enter the selected menu item. |
- DC OUT
Turn on DC output and set the voltage and amperage. - USB
Choose whether your USB-A ports are on or off when you turn on your Omnicharge. The default setting is on. - SCREEN OFF TIMER
Set the screen auto shut-off time here. The default setting is 5 min.
5. AUTO SHUT DOWN
Set the power auto shut-off time here. The default setting is 5 min.
6. TEMPERATURE
Choose whether your temperature is displayed in Celcius or Fahrenheit
7. BUTTON LIGHT
Choose whether the button lights are on or off. The default setting is on.
8. ABOUT
Find the model name, capacity, firmware version, and serial number information here.
AC OUTLET
Max output power: 120W
- Quick press AC Output Button to turn the AC outlet on/off
- The AC icon should appear on the screen
![]() |
AC 120V/230V AC output |
Power any device
Note: Due to the high power pure sinewave AC output, you might experience some electrical interference on the USB-A and USB-C ports when simultaneously outputting from the AC outlet.
DC OUTPUT
5V – 60V with 0.1V/A Accuracy, up to 8A (150W max)
The DC output feature can directly charge your laptop without needing your laptop charger. Warning: Before using DC Output make sure you know the correct voltage for your laptop. Using the wrong voltage can damage your device.
Note: For more information visit our support page at www.omnicharge.co/support
Set the voltage and amperage through the menu (You can also click the DC Output Button to jump to Step 2)
Omnicharge keeps 4 voltage presets. You can press and hold the power button while selecting a preset to customize the voltage and amperage.
DC icon will appear on the screen
Adjustable DC output
Power your device through the DC port (MR30)
USB-A PORTS
5V=3A, 9V=2A, 12V=1.5A QC3.0 compatible
USB-C INPUT/OUTPUT PORT 5V, 9V, 12V, 15V, 20V, up to 3A 60W max |
![]() |
THE OMNICHARGE CAN BE RECHARGED IN A VARIETY OF WAYS DC Input 5-25V, 4.5A max, 90W max USB-C Input 5V=3A, 9V=3A, 12V=3A, 15V=3A, 20V=3A, 60W max |
![]() |
Charging from the Wall
Use the included AC wall charger, or other power adapters like your laptop charger to recharge your Omnicharge.
Note: Make sure the output voltage of your adapter falls within the 5V – 25V range.
The Omni Ultimate can accept 5.5 x 2.5 mm barrel plugs.
TECHNICAL SPECIFICATION
GENERAL
Weight: 3.08 lbs (1.4 Kg)
Dimension: 6.6″x 5.7″x 2.1″(167.5 x 145 x 54 mm)
USB-C
Bidirectional Input/output charging
Input: USB-PD, 5V~20V, up to 3A, 60W max
Output: 5V=3A=9V=3A=12V=3A=15V=3A=20V=3A, up to 3A, 60W max
USB-A Output
Port1: QC 3.0,5V=3A,9V=2A,12V=1.5A
Port2: QC 3.0,5V=3A,9V=2A,12V=1.5A
DC INPUT
Input: 5~25V, up to 4.5A, 90W max
DC OUTPUT
Output: 5~60V, up to 5A, 150W max
AC PORT
120V AC, 60Hz, 120W max US version
230V AC, 50Hz, 120W max EU version
CAPACITY
12 cells, 38400 mAh, 142Wh max at 3.7V
OPERATING ENVIRONMENT
Temperature 0°C-40°C
Humidity 30-70%
Altitude ≤2000m
MADE IN CHINA
© 2021 Omnicharge.
is a trademark of Omnicharge Inc.
THANK YOU
www.omnicharge.co
CUSTOMER SUPPORT
All Omnicharge products have gone through quality inspection. If you find your Omnicharge or any Omnicharge accessory is experiencing or demonstrating any abnormal behavior, immediately stop all product use and contact us at support@omnicharge.co
FOLLOW US
![]() |
https://www.facebook.com/omnicharge |
![]() |
https://www.instagram.com/omnicharge |
![]() |
https://www.youtube.com/c/omnicharge |
![]() |
https://twitter.com/omni_charge |
© 2021 Omnicharge.
is a trademark of Omnicharge Inc.
Documents / Resources
![]() |
omnicharge Omni Ultimate [pdf] User Manual Omni Ultimate |