Quick Start Use Manual OLEI A090 Laser Distance Sensor

A090
Laser Distance Sensor
Sensing Reality

Electrical parameters and specifications

Table 1 Electrical characteristics

Parameter Name Parameter values
Input voltage 7-26V
Average current 100mA(Vin= 10V)
Peak current <150mA(Vin= 10V)
Type of communication interface RS485, CAN, 1 analog output,2 switching output, 1 switching input
Power consumption <1.5W

Table 2 Basic parameters

Measuring principle Phalle
Measuring range 0.05-90m(90%,300Iux,single) 0.2-45m(90%,300Iux,30Hz) I
Resolution 0.1mm
Measurement reference Front-end distance measuring sensor
Accuracy ±1.5mm (90% diffuse reflection <20m)
±3.0mm (full range)
Measuring frequency Support single measurement and continuous measurement: frequency of continuous measurement:
5Hz,10Hz,20Hz, and 30Hz are available.
Light source 650-660nm
Laser class Class II (laser power is between 0.75-0.95mW)
Typical spot size (distance) 7mm©10m
Initialization lime <1000ms
Holder material Metal (aluminum)
Type of connection M12,12P,Male
Weight(excluding accessories and packaging materials) 350g
Dimensions(width x length x height) 79•127•31mm

Notice: *1 The specific measurement range will change due to the measuring frequency, light intensity, and target reflectivity.

Appearance and dimension

2.1 Appearance

OLEI A090 Laser Distance Sensor - fig

2.2 Installation dimension

OLEI A090 Laser Distance Sensor - fig1

Instruction of wiring

3.1 Description of interface terminal
The external interface adopts 12P, M12 male aviation plug, and the pin sequence is as shown in the figure below:

OLEI A090 Laser Distance Sensor - fig3

A 2m-long 12-core molding cable is included, with one end of an M 12 female aviation plug, and the other end of colored wire.

PIN  Definition  Description 
2 V+ 7 … 26V
3 GND av
4 1 Switching output channel 1, push-pull output, maximum drive current 200mA
5 2 Switching output channel 2, push-pull output, maximum drive current 200mA
6 VCC 10 voltage, 12V-24V
8 485A 485 output A
7 485B 485 output B
8 Multi1 CANH, IIC_SDA,5VIO(toggle switch to shift; program functions also need to be  set to corresponding functions through parameters), default to CANH
9 Multi2 CANL, IIC_SCL,5VIO(toggle switch to shift; program functions also need to be  set to corresponding functions through parameters), default to CANL
10 INDIO 10 ground
11 11 INPUT1, switching input channel 1, when not connected, it is high-level, Active low
12 analogous Analog signal output, support -5V,0-10V,4-20mA, 0-20mA,0-24mA,parameter  selection is required, default to 4-20mA out ut

Notice:

  1. The 485 interfaces, CAN interface, analog output, 10 output, and input all adopt a fully isolated design. Thus do not connect VCCIO and GNDIO with V+ and GND  together, otherwise, the effect of power isolation will not be achieved.
  2. If only 485 and CAN are used, VCCIO and GNDIO may not be connected. If the switching output and input functions are used, VCCIO and GNDIO must be connected.
  3. If the analog output is used, GNDIO should be taken as the reference ground.
  4. Communication interface description

4.1 RS485 Modbus RTU communication protocol
Please refer to “Industrial Ranging Sensor Modbus RTU Communication Protocol” for detailed information.
4.2 CAN communication protocol
The CAN communication protocol supports standard frames and extended frames; the communication parameters could be set via the RS485 bus. Please refer to “Industrial  Ranging Sensor Modbus RTU Communication Protocol” for a detailed CAN communication setting method. For CAN communication protocol, please refer to “Industrial  Ranging Sensor
CAN Communication Protocol”.
4.3 Analog output
There are 6 options for analog output function, namely:
=0 off
=1 0-5V
=2 0-10V
=3 4-20mA
=4 0-20mA
=5 0-24mA
The configuration parameters should be set via the RS485 bus. Please refer to “Industrial Ranging Sensor Modbus RTU Communication Protocol” for details.

4.4 Switching outputs
The switching output is in push-pull mode and supports two modes of output setting, namely (1: ON> OFF, 2: ON <OFF). The device automatically judges the mode according to the set hysteresis parameters.
1) Hysteresis parameter: ON level>OFF level
OLEI A090 Laser Distance Sensor - fig2The 10 output configuration parameters should be set via the RS485 bus.
Please refer to “Industrial Ranging Sensor Modbus RTU Communication Protocol” for details.

4.5 Switching input
The functional parameters of the switching input have three modes, as shown below:
=0 off
=1 not connected or high level to start the measurement, low level to stop measurement
=2 not connected or high level to stop measurement, low level to start measurement
10 input configuration parameters should be set via the RS485 bus.
Please refer to “Industrial Ranging Sensor Modbus RTU Communication Protocol” for details.
5. Service and maintenance
Please visit the OLEI official website for inquiry of service and maintenance information;
Website: www.ole-systems.com
Path: Service and Support>>Service and maintenance

OLEI A090 Laser Distance Sensor -QR CODEhttp://weixin.qq.com/r/SCrB2WrE2zekrS66939a
MorpheusTEK Inc
Exclusive OLEI Distributor Partner
sales@morpheustek.com
+1-610 883 6026

Documents / Resources

OLEI A090 Laser Distance Sensor [pdf] User Manual
A090 Laser Distance Sensor, A090, Laser Distance Sensor, Distance Sensor, Sensor

References

Leave a comment

Your email address will not be published. Required fields are marked *