1.Electrical parameters and specifications

Table 1 Electrical characteristics

Parameter Name
Input voltage Average current
Peak current Type of communication interface

Parameter values 7-26V 100mA(Vin=10V) <150mA(Vin=10V)
RS485,CAN,1 analog output,2 switching output, 1 switching input

Power consumption

<1.5W Table 2 Basic arameters

Measuring range

0.05-90m(90%,300lux,single) 0.2-45m(90%,300lux,30Hz) ·1

Resolution

0.1mm

Measurement reference Front-end distance measuring sensor

Accuracy

±1.5mm (90% diffuse reflection,<20m) ±3.0mm (full range)

Measuring frequency Light source

Support single measurement and continuous measurement; frequency of continuous measurement: 5Hz,10Hz,20Hz,30Hz are available.
650-660nm

Laser class
Typical spot size (distance)
Initialization time
Holder material
Type of connection Weight(excluding accessories and packaging materials) Dimensions(width x len th x hei ht

Class II (laser power is between 0.75~0.95mW) 7mm@10m <1000ms Metal (aluminum) M12,12P,Male 350g
79·127·31mm

Notice: *1 The specific measurement range will change due to the measuring frequency, light intensity, and target reflectivity.

2. Appearance and dimension 2.1 Appearance
Button and LED indicator

3. Instruction of wiring
3.1 Description of interface terminal The external interface adopts 12P, M12 male aviation plug, and the pin sequence is as shown in the figure below:

Aviation plug
2.2 Installation dimension

Laser emission glass window

A 2m-long 12-core molding cable is included, with one end of M12 female aviation plug, and the other end of colored wire.

PIN

Definition

Description

V+

7 ... 26V

2

GND

av

3

01

Switching output channel 1, push-pull output,

maximum drive current 200mA

4

02

Switching output channel 2, push-pull output, maximum drive current 200mA

5

VCCIO

10 voltage, 12V-24V

6

485A

485 output A

7

485B

485 output B

CANH, IIC_SDA,5VIO(toggle switch to shift;program

8

Multi1

functions also need to be set to corresponding functions

through parameters),default to CANH

CANL, IIC_SCL,5VIO(toggle switch to shift;program

Multi2

functions also need to be set to corresponding functions

through parameters),default to CANL

10

GNDIO

10 ground

11

11

INPUT1,switching input channel 1,when not connected,

it is high level,Active low

Analog signal output, support -5V,0-10V,4-20mA,

12

AnalogOut 0-20mA,0-24mA,parameter selection is required,

default to 4-20mA out ut

2

3

Notice: 1) The 485 interface, CAN interface, analog output, 10 output and input all adopt a fully isolated design. Thus do not connect VCCIO and GNDIO with V+ and GND together, otherwise the effect of power isolation will not be achieved. 2) If only 485 and CAN are used, VCCIO and GNDIO may not be connected. If the switching output and input functions are used, VCCIO and GNDIO must be connected. 3) If analog output is used, GNDIO should be taken as the reference ground.

4 Communication interface description
4.1 RS485 modbus RTU communication protocol Please refer to "Industrial Ranging Sensor Modbus RTU Communication Protocol" for detailed information.
4.2 CAN communication protocol The CAN communication protocol supports standard frames and extended frames; the communication parameters could be set via RS485 bus. Please refer to "Industrial Ranging Sensor Modbus RTU Communication Protocol" for detailed CAN communication setting method. For CAN communication protocol, please refer to "Industrial Ranging Sensor CAN Communication Protocol".
4.3 Analog output
There are 6 options for analog output function, namely: =0 off =1 0-5V =2 0-10V =3 4-20mA =4 0-20mA =5 0-24mA The configuration parameters should to be set via RS485 bus. Please refer to "Industrial Ranging Sensor Modbus RTU Communication Protocol" for details.

4.4 Switching outputs
The switching output is in push-pull mode and supports two modes of output setting, namely (1: ON> OFF, 2: ON <OFF). The device automatically judges the mode according to the set hysteresis parameters.

1) Hysteresis parameter: ON level>OFF level
-DO

closed

When the distance increases and exceeds the ON distance point, high

level is output . When the distance

decreases and drops to the OFF

open 1------'-----'

distance point, low level is output.

-----------· DISTANCE

0

Off

On

2) Hysteresis parameter: ON level<OFF level

DO open

When the distance increases and exceeds the OFF distance point, low level is output. When the distance
decreases and drops to the ON distance value, high level is output.

------------- DISTANCE

0

On

Off

The 10 output configuration parameters should be set via the RS485 bus. Please refer to "Industrial Ranging Sensor Modbus RTU Communication Protocol" for details.

4.5 Switching input
The functional parameters of the switching input have three modes, as shown below: =0 off =1 not connected or high level to start measurement, low level to stop measurement =2 not connected or high level to stop measurement, low level to start measurement 10 input configuration parameters should be set via RS485 bus. Please refer to "Industrial Ranging Sensor Modbus RTU Communication Protocol" for details.
5. Service and maintenance
Please visit the OLEI official website for enquiry of service and maintenance information; Website: www.ole-systems.com Path: Service and Support>>Service and maintenance

l!l . l!l
!?.EJ
r1::,.r ·"' . ·
FollowOLEI!

MorpheusTEK Inc Exclusive OLEI Distributor Partner sales@morpheustek.com +1-610 883 6026

4

6

7



References

Adobe Illustrator CS5 Adobe PDF library 9.90