NuTone FG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces
Technical Specifications
- Model: FG7S (A and K Series)
- Type: High Efficiency Upflow/Horizontal and Downflow Gas
Furnaces - Induced Draft
- 80+ AFUE
- Input: 45,000 – 126,000 Btuh
Features and Benefits
- GAS FURNACE COMPONENTS:
- Blower Assembly
- Blower Door Switch
- Burner Assembly
- Control Board
- Flame Sensor
- Gas Manifold
- Gas Valve
- Igniter
- Inducer
- Insulated Combustion Tube (Downflow Models)
- Low Voltage Transformer
- Main Air Limit Switch
- Pressure Switch
- Roll-Out Switch(s)
Dimensions
A Series
Model #’s | A Dimension | B Dimension | C Dimension | D Dimension |
---|---|---|---|---|
045-23A | 12 | 12 | 21 | 14 |
054-23A | 12 | 12 | 15 | 16 |
072-24B | 15 | 16 | 21 | 14 |
090-24B | 15 | 16 | 19 | 19 |
072-35C | 21 | 14 | 19 | 19 |
090-35C | 21 | 14 | 22 | 23 |
108-35C | 21 | 19 | 22 | 23 |
126-45D | 23 | 19 | 22 | 23 |
K Series
Model #’s | A Dimension | B Dimension | C Dimension | D Dimension |
---|---|---|---|---|
054-23A | 12 | 12 | 21 | 14 |
072-24B | 15 | 16 | 21 | 14 |
090-24B | 15 | 16 | 19 | 19 |
108-35C | 21 | 14 | 19 | 19 |
126-45D | 22 | 23 | 19 | 19 |
Blower Performance – FG7SA Model Number
Heating Input (Btuh) | Motor Speed | External Static Pressure (Inches Water Column) | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 |
---|---|---|---|---|---|---|---|---|---|---|
45,000 | High* | 1260 | 1205 | 1145 | 1080 | 1025 | 960 | 890 | 825 | |
Med-High | 955 | 825 | ||||||||
Med-Low** | 950 | 800 |
Product Usage Instructions
FAQ
Q: Where can the high-efficiency gas furnace be installed?
A: The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet.
Q: Is the gas furnace design certified?
A: Yes, the gas furnace design is certified by CSA for application in Canada and the United States.
TECHNICAL SPECIFICATIONS
FG7S (A and K Series)
High-Efficiency Upflow/Horizontal and
Downflow Gas Furnaces
Induced Draft – 80+ AFUE
Input 45,000 – 126,000 Btuh
The high-efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.
FEATURES and BENEFITS
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent-free.
• Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
• Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
• 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
• 30 second post purge: Increases life of heat exchanger.
• Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology.
• Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
• High static blowers: All models equipped with high static blowers.
• 90 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil.
• Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
• High efficiency blower kits: Maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized.
• Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection.
• LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
• Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
• Integrated control board: Incorporates connections for electronic air cleaner and humidifier.
• Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws.
• Blower Compartment: Insulated for ultra quiet operation.
• Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.
GAS FURNACE COMPONENTS
- Blower Assembly
- Blower Door Switch
- Burner Assembly
- Control Board
- Flame Sensor
- Gas Manifold
- Gas Valve
- Igniter
- Inducer
- Insulated Combustion Tube wnflow Models)
- Low Voltage Transformer
- Main Air Limit Switch
- Pressure Switch
- Roll-Out Switch(s)
DIMENSIONS
FG7SA 80+ High Efficiency Upflow/Horizontal Series
FG7SK 80+ High Efficiency Downflow Series
BLOWER PERFORMANCE – FG7SA
Model Number |
Heating Input (Btuh) |
Motor Speed |
External Static Pressure (Inches Water Column) | |||||||||||||||
0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | |||||||||||
CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | |||
High* | 1260 | 26 | 1205 | 28 | 1145 | 29 | 1080 | 31 | 1025 | 33 | 960 | 35 | 890 | 37 | 825 | 40 | ||
SA045( )-23A
Bottom Return |
45,000 |
Med-High
Med-Low** |
955
825 |
35
40 |
950
800 |
35
42 |
940
760 |
35
44 |
935
730 |
36
46 |
925
690 |
36
48 |
860
650 |
39
51 |
800
600 |
42 | 725
530 |
46 |
– | – | |||||||||||||||||
Low | 655 | 51 | 630 | 53 | 610 | 55 | 580 | – | 550 | – | 520 | – | 480 | – | 435 | – | ||
High* | 1350 | 25 | 1290 | 26 | 1225 | 27 | 1155 | 29 | 1100 | 30 | 1025 | 33 | 950 | 35 | 885 | 38 | ||
SA045( )-23A
Side Return |
45,000 |
Med-High
Med-Low** |
1025
885 |
33
38 |
1015
855 |
33
39 |
1005
815 |
33
41 |
1000
780 |
33
43 |
990
740 |
34
45 |
920
695 |
36
48 |
855
640 |
39
52 |
775
565 |
43 |
– | ||||||||||||||||||
Low | 700 | 48 | 675 | 49 | 655 | 51 | 620 | – | 590 | – | 555 | – | 515 | – | 465 | – | ||
High* | 1260 | 32 | 1205 | 33 | 1145 | 35 | 1080 | 37 | 1025 | 39 | 960 | 42 | 890 | 45 | 825 | 48 | ||
SA054( )-23A
Bottom Return |
54,000 |
Med-High
Med-Low** |
955
825 |
42
48 |
950
800 |
42
50 |
940
760 |
43
53 |
935
730 |
43
55 |
925
690 |
43 | 860
650 |
47 | 800
600 |
50 | 725
530 |
55 |
– | – | – | – | |||||||||||||||
Low | 655 | – | 630 | – | 610 | – | 580 | – | 550 | – | 520 | – | 480 | – | 435 | – | ||
High* | 1350 | 30 | 1290 | 31 | 1225 | 33 | 1155 | 35 | 1100 | 36 | 1025 | 39 | 950 | 42 | 885 | 45 | ||
SA054( )-23A
Side Return |
54,000 |
Med-High
Med-Low** |
1025
885 |
39
45 |
1015
855 |
39
47 |
1005
815 |
40
49 |
1000
780 |
40
51 |
990
740 |
40
54 |
920
695 |
43 | 855
640 |
47 | 775
565 |
52 |
– | – | – | ||||||||||||||||
Low | 700 | – | 675 | – | 655 | – | 620 | – | 590 | – | 555 | – | 515 | – | 465 | – | ||
High* | 1685 | 32 | 1640 | 33 | 1605 | 33 | 1565 | 34 | 1515 | 35 | 1475 | 36 | 1415 | 38 | 1345 | 40 | ||
SA072( )-24B
Bottom Return |
72,000 |
Med-High
Med-Low** |
1330
1175 |
40
45 |
1295
1155 |
41
46 |
1275
1125 |
42
47 |
1245
1100 |
43
48 |
1215
1075 |
44
50 |
1185
1045 |
45
51 |
1135
1010 |
47
53 |
1070
955 |
50
56 |
Low | 930 | 57 | 895 | 60 | 885 | 60 | 850 | – | 825 | – | 800 | – | 770 | – | 740 | – | ||
High* | 1770 | 30 | 1720 | 31 | 1685 | 32 | 1645 | 32 | 1590 | 34 | 1550 | 34 | 1485 | 36 | 1415 | 38 | ||
SA072( )-24B
Side Return |
72,000 |
Med-High
Med-Low** |
1400
1235 |
38
43 |
1360
1215 |
39
44 |
1340
1180 |
40
45 |
1310
1155 |
41
46 |
1275
1130 |
42
47 |
1245
1100 |
43
48 |
1190
1060 |
45
50 |
1125
1005 |
47
53 |
Low | 975 | 55 | 940 | 57 | 930 | 57 | 890 | 60 | 865 | – | 840 | – | 810 | – | 775 | – | ||
High* | 1610 | 41 | 1575 | 42 | 1530 | 44 | 1485 | 45 | 1440 | 46 | 1385 | 48 | 1340 | 50 | 1275 | 52 | ||
SA090( )-24B
Bottom Return |
90,000 |
Med- High**
Med-Low |
1295
1155 |
51
58 |
1260
1130 |
53
59 |
1235
1100 |
54
61 |
1220
1070 |
55 | 1175
1035 |
57 | 1135
1015 |
59 | 1095
965 |
–
– |
1015
920 |
–
– |
– | – | – | ||||||||||||||||
Low | 880 | – | 860 | – | 830 | – | 800 | – | 765 | – | 740 | – | 675 | – | 660 | – | ||
High* | 1690 | 39 | 1655 | 40 | 1610 | 41 | 1560 | 43 | 1510 | 44 | 1455 | 46 | 1405 | 47 | 1340 | 50 | ||
SA090( )-24B
Side Return |
90,000 |
Med- High**
Med-Low |
1360
1215 |
49
55 |
1325
1190 |
50
56 |
1300
1155 |
51
58 |
1280
1125 |
52
59 |
1235
1090 |
54 | 1190
1065 |
56 | 1150
1015 |
58 | 1065
965 |
–
– |
– | – | – | ||||||||||||||||
Low | 925 | – | 900 | – | 870 | – | 840 | – | 800 | – | 775 | – | 710 | – | 695 | – | ||
High* | 1950 | – | 1865 | – | 1790 | – | 1715 | – | 1630 | – | 1550 | – | 1475 | 36 | 1390 | 38 | ||
SA072( )-35C
Bottom Return |
72,000 |
Med-High
Med-Low** |
1860
1300 |
– | 1780
1240 |
– | 1710
1200 |
– | 1635
1160 |
– | 1575
1120 |
– | 1500
1065 |
36
50 |
1415
995 |
38
54 |
1325
910 |
40
59 |
41 | 43 | 44 | 46 | 48 | ||||||||||||||
Low | 1165 | 46 | 1115 | 48 | 1060 | 50 | 1025 | 52 | 985 | 54 | 940 | 57 | 890 | 60 | 825 | 65 | ||
High* | 2030 | – | 1940 | – | 1860 | – | 1785 | – | 1695 | – | 1615 | – | 1535 | 35 | 1445 | 37 | ||
SA072( )-35C
Side Return |
72,000 |
Med-High
Med-Low** |
1935
1350 |
– | 1850
1290 |
– | 1780
1250 |
– | 1700
1205 |
– | 1340
1165 |
40
46 |
1560
1110 |
– | 1470
1035 |
36
52 |
1380
945 |
39
56 |
40 | 41 | 43 | 44 | 48 | ||||||||||||||
Low | 1215 | 44 | 1160 | 46 | 1105 | 48 | 1065 | 50 | 1025 | 52 | 980 | 54 | 925 | 58 | 860 | 62 |
Model Number |
Heating Input (Btuh) |
Motor Speed |
External Static Pressure (Inches Water Column) | ||||||||||||||||
0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | ||||||||||||
CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | ||||
SA072( )-35C Side + Bottom or 2 Sides |
72,000 |
High* Med-High Med-Low**
Low |
2050
1955 1365 1225 |
–
– |
1960
1870 1300 1170 |
–
– |
1880
1800 1260 1115 |
–
– |
1800
1715 1220 1075 |
–
– |
1710
1655 1175 1035 |
–
– |
1630
1575 1120 985 |
–
– |
1550
1485 1045 935 |
– | 1460
1390 955 865 |
37
38 56 62 |
|
36
51 57 |
|||||||||||||||||||
39
44 |
41
46 |
42
48 |
44
50 |
45
52 |
48
54 |
||||||||||||||
High* | 1940 | – | 1860 | 36 | 1790 | 37 | 1710 | 39 | 1625 | 41 | 1540 | 43 | 1450 | 46 | 1355 | 49 | |||
SA090( )-35C
Bottom Return |
90,000 |
Med-High**
Med-Low |
1820
1290 |
37
52 |
1760
1245 |
38
54 |
1695
1200 |
39
56 |
1620
1155 |
41
58 |
1545
1110 |
43
60 |
1466
1060 |
45
63 |
1380
995 |
48 | 1280
915 |
52 | |
– | – | ||||||||||||||||||
Low | 1145 | 58 | 1110 | 60 | 1070 | 62 | 1035 | 64 | 1000 | – | 950 | – | 905 | – | 835 | – | |||
High* | 2020 | – | 1935 | – | 1860 | 36 | 1780 | 37 | 1690 | 39 | 1600 | 42 | 1510 | 44 | 1410 | 47 | |||
SA090( )-35C
Side Return |
90,000 |
Med-High**
Med-Low |
1895
1345 |
35
50 |
1830
1295 |
36
51 |
1765
1250 |
38
53 |
1685
1200 |
40
56 |
1610
1155 |
41
58 |
1525
1100 |
44
61 |
1435
1035 |
46
64 |
1330
950 |
50 | |
– | |||||||||||||||||||
Low | 1190 | 56 | 1155 | 58 | 1115 | 60 | 1075 | 62 | 1040 | 64 | 980 | – | 940 | – | 870 | – | |||
SA090( )-35C Side + Bottom or 2 Sides |
90,000 |
High* Med-High** Med-Low
Low |
2040
1910 1355 1205 |
– | 1955
1850 1310 1165 |
– | 1880
1780 1260 1125 |
35
37 53 59 |
1795
1700 1215 1085 |
37
39 55 61 |
1705
1625 1165 1050 |
39
41 57 63 |
1620
1540 1115 1000 |
41
43 60 |
1525
1450 1050 950 |
44
46 63 |
1425
1345 960 875 |
47
50 |
|
35
49 55 |
36
51 57 |
||||||||||||||||||
–
– |
|||||||||||||||||||
– | – | ||||||||||||||||||
High* | 2205 | 36 | 2150 | 37 | 2095 | 38 | 2030 | 39 | 1970 | 41 | 1900 | 42 | 1830 | 44 | 1740 | 46 | |||
SA108( )-35C
Bottom Return |
108,000 |
Med-High**
Med-Low |
2050
1700 |
39
47 |
1995
1680 |
40
48 |
1955
1645 |
41
49 |
1895
1610 |
42
50 |
1840
1565 |
43
51 |
1775
1525 |
45
52 |
1700
1460 |
47
55 |
1610
1375 |
50
58 |
|
Low | 1390 | 58 | 1370 | 58 | 1355 | 59 | 1320 | 61 | 1300 | 62 | 1270 | 63 | 1225 | 65 | 1175 | – | |||
High* | 2295 | 35 | 2235 | 36 | 2180 | 37 | 2110 | 38 | 2050 | 39 | 1975 | 41 | 1900 | 42 | 1810 | 44 | |||
SA108( )-35C
Side Return |
108,000 |
Med-High**
Med-Low |
2130
1770 |
38
45 |
2075
1750 |
39
46 |
2035
1710 |
39
47 |
1970
1675 |
41
48 |
1915
1630 |
42
49 |
1845
1585 |
43
50 |
1765
1520 |
45
53 |
1675
1430 |
48
56 |
|
Low | 1445 | 55 | 1425 | 56 | 1410 | 57 | 1375 | 58 | 1350 | 59 | 1320 | 61 | 1275 | 63 | 1225 | 65 | |||
High* | 2315 | 35 | 2260 | 35 | 2200 | 36 | 2130 | 38 | 2070 | 39 | 1995 | 40 | 1925 | 42 | 1825 | 44 | |||
SA108( )-35C
Side + Bottom |
108,000 |
Med-High** Med-Low | 2155
1785 |
37
45 |
2095
1765 |
38
45 |
2055
1725 |
39
46 |
1990
1690 |
40
47 |
1930
1645 |
41
49 |
1865
1600 |
43
50 |
1785
1535 |
45
52 |
1690
1445 |
47
55 |
|
or 2 Sides | Low | 1460 | 55 | 1440 | 56 | 1425 | 56 | 1385 | 58 | 1365 | 59 | 1335 | 60 | 1285 | 62 | 1235 | 65 | ||
High* | 2255 | 41 | 2200 | 42 | 2125 | 44 | 2065 | 45 | 2010 | 46 | 1935 | 48 | 1855 | 50 | 1755 | 53 | |||
SA126( )-45D
Bottom only or 2 openings |
126,000 |
Med-High**
Med-Low |
2075
1720 |
45
54 |
2025
1695 |
46
55 |
1970
1655 |
47
56 |
1940
1630 |
48
57 |
1875
1580 |
50
59 |
1810
1520 |
52
61 |
1750
1455 |
53
64 |
1680
1390 |
56
67 |
|
– | 1310 | – | 1300 | – | 1260 | – | 1230 | – | |||||||||||
Low | 1360 | 69 | 1375 | 68 | 1365 | 68 | 1315 | ||||||||||||
High* | 2230 | 42 | 2180 | 43 | 2105 | 44 | 2045 | 46 | 1990 | 47 | 1915 | 49 | 1835 | 51 | 1740 | 54 | |||
SA126( )-45D
Side Return |
126,000 |
Med-High**
Med-Low |
2055
1705 |
45
55 |
2005
1680 |
47
56 |
1950
1640 |
48
57 |
1920
1615 |
49
58 |
1855
1565 |
50
60 |
1790
1505 |
52
62 |
1735
1440 |
54
65 |
1665
1375 |
56
68 |
|
Low | 1345 | 69 | 1360 | 69 | 1350 | 69 | 1300 | – | 1230 | – | 1290 | – | 1250 | – | 1220 | – |
Model Number |
Heating Input (Btuh) |
Motor Speed |
External Static Pressure (Inches Water Column) | ||||||||||||||||
0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | ||||||||||||
CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | CFM | Rise | ||||
SK054( )-23A |
54,000 |
High* Med-High Med-Low**
Low |
1375
1155 790 650 |
29
35 51 |
1340
1130 775 640 |
30
35 52 |
1300
1110 765 630 |
31
36 52 |
1270
1085 750 610 |
31
37 53 |
1225
1055 730 590 |
33
38 55 |
1175
1015 700 565 |
34
39 |
1115
975 665 530 |
36
41 |
1035
910 610 480 |
39
44 |
|
–
– |
–
– |
–
– |
|||||||||||||||||
– | – | – | – | – | |||||||||||||||
SK072( )-24B |
72,000 |
High* Med-High Med-Low**
Low |
1610
1295 1155 910 |
33
41 46 59 |
1590
1275 1135 885 |
34
42 47 60 |
1575
1260 1115 860 |
34
42 48 |
1560
1250 1095 835 |
34
43 49 |
1540
1220 1065 810 |
35
44 50 |
1495
1195 1040 785 |
36
45 51 |
1460
1170 1015 765 |
37
46 53 |
1415
1120 980 735 |
38
48 54 |
|
– | – | – | – | – | – | ||||||||||||||
SK090( )-24B |
90,000 |
High* Med-High Med-Low**
Low |
1675
1330 1180 940 |
40
50 56 |
1655
1315 1165 925 |
40
51 57 |
1640
1300 1150 900 |
41
51 58 |
1620
1280 1135 880 |
41
52 59 |
1590
1255 1115 850 |
42
53 60 |
1560
1230 1090 825 |
43
54 61 |
1520
1200 1060 795 |
44
56 63 |
1475
1150 1010 760 |
45
58 66 |
|
– | – | – | – | – | – | – | – | ||||||||||||
SK108( )-35C |
108,000 |
High* Med-High Med-Low**
Low |
2395
2190 1785 1145 |
33
37 45 |
2335
2135 1770 1110 |
34
37 45 |
2285
2115 1740 1070 |
35
38 46 |
2230
2080 1725 1035 |
36
38 46 |
2200
2030 1685 1000 |
36
39 47 |
2140
1975 1645 950 |
37
41 49 |
2080
1915 1615 905 |
38
42 50 |
2000
1810 1565 835 |
40
44 51 |
|
– | – | – | – | – | – | – | – | ||||||||||||
SK126( )-45D |
126,000 |
High* Med-High Med-Low**
Low |
2445
2195 1795 1480 |
38
43 52 63 |
2395
2170 1780 1475 |
39
43 52 63 |
2385
2140 1770 1450 |
39
44 53 64 |
2330
2120 1760 1440 |
40
44 53 65 |
2275
2090 1725 1440 |
41
45 54 65 |
2225
2030 1690 1415 |
42
46 55 |
2130
1975 1655 1405 |
44
47 56 |
2015
1855 1610 1375 |
46
50 58 |
|
– | – | – |
NOTES:
Can be C or N
- Two openings are required for airflows above 1600 CFM if filter(s) is(are) adjacent to furnace.
- Factory Set Cooling Speed 2. Temperature rises in the table are approximate. Actual temperature rises may vary.
- Factory Set Heating Speed 3. Temperature rises shaded in gray are not recommended.
NOTES:
Can be C or N
- Factory Set Cooling Speed 1. Temperature rises in the table are approximate. Actual temperature rises may vary.
- Factory Set Heating Speed 2. Temperature rises shaded in gray are not recommended.
MODEL IDENTIFICATION CODE
SPECIFICATIONS
FG7SA MODEL NUMBERS | -045-23A | -054-23A | -072-24B | -090-24B | -072-35C | -090-35C | -108-35C | -126-45D |
Input – Btuh (a) | 45,000 | 54,000 | 72,000 | 90,000 | 72,000 | 90,000 | 108,000 | 126,000 |
Heating Capacity – Btuh | 36,000 | 43,200 | 57,600 | 72,000 | 57,600 | 72,000 | 86,400 | 100,800 |
AFUE | 80.0 | 80.0 | 80.0 | 80.0 | 80.0 | 80.0 | 80.0 | 80.0 |
Blower D x W | 10 x 6 | 10 x 6 | 11x 8 | 11 x 8 | 10 x 10 | 10 x 10 | 11 x 10 | 11 x 10 |
Motor H.P. – Speed – Type | 1/3 – 4 – PSC | 1/3 – 4 – PSC | 1/2 – 4 – PSC | 1/2 – 4 – PSC | 1/2 – 4 – PSC | 1/2 – 4 – PSC | 1.0 – 4 – PSC | 1.0 – 4 – PSC |
Motor FLA | 4.80 | 4.80 | 8.20 | 8.20 | 7.50 | 7.50 | 13.75 | 13.75 |
Rated Ext. SP – In. W.C. | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Rise Range – ºF | 30-60 | 30-60 | 35-65 | 35-65 | 35-65 | 35-65 | 40-70 | 40-70 |
Shipping Weights | 100lbs | 100lbs | 110lbs | 115lbs | 115lbs | 120lbs | 125lbs | 145lbs |
FG7SK MODEL NUMBERS | -054-23A | -072-24B | -090-24B | -108-35C | -126-45D |
Input – Btuh (a) | 54,000 | 72,000 | 90,000 | 108,000 | 126,000 |
Heating Capacity – Btuh | 43,200 | 57,600 | 72,000 | 86,400 | 100,800 |
AFUE | 80.0 | 80.0 | 80.0 | 80.0 | 80.0 |
Blower D x W | 10 x 6 | 11 x 8 | 11 x 8 | 11 x 10 | 11 x 10 |
Motor H.P. – Speed – Type | 1/3 – 4 – PSC | 1/2 – 4 – PSC | 1/2 – 4 – PSC | 3/4 – 4 – PSC | 1.0 – 4 -PSC |
Motor FLA | 4.80 | 8.20 | 8.20 | 13.75 | 13.75 |
Rated Ext. SP – In. W.C. | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Rise Range – ºF | 30-60 | 35-65 | 35-65 | 40-70 | 40-70 |
Shipping Weights | 100lbs | 110lbs | 115lbs | 125lbs | 145lbs |
ACCESSORIES
FG7S (A, K) KITS | |
Description | SKU |
“A” Cabinet fixed speed, high efficiency, FSHE | 904872 |
“B” Cabinet fixed speed, high efficiency, FSHE | 904873 |
“C” Cabinet fixed speed, high efficiency, FSHE | 904874 |
“D” Cabinet fixed speed, high efficiency, FSHE | 904875 |
“A” Cabinet variable speed, high efficiency, VSHE | 904876 |
“B” Cabinet variable speed, high efficiency, VSHE | 904877 |
“C” Cabinet variable speed, high efficiency, VSHE | 904878 |
“D” Cabinet variable speed, high efficiency, VSHE | 904879 |
“A” Cabinet downflow sub base kit | 902974 |
“B”, “C”, “D” Cabinet downflow sub base kit | 904911 |
U.S. LP Conversion kit (0 to 10,000 ft.) | 904914 |
Canada LP Conversion kit (0 to 4,500 ft.) | 904915 |
Bottom return filter 20 per box, “A” cabinet | 903088 |
Bottom return filter 20 per box, “B” cabinet | 904916 |
Bottom return filter 20 per box, “C” cabinet | 904917 |
Bottom return filter 20 per box, “D” cabinet | 904918 |
Side return filter kit | 541036 |
GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (08/2016)
www.nutonehvac.com
NuTone® trademark used under license. © Nortek Global HVAC, LLC. All Rights Reserved.
Documents / Resources
![]() |
NuTone FG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces [pdf] Owner's Manual FG7S A and K Series High Efficiency Upflow Horizontal and Downflow Gas Furnaces, FG7S A and K Series, High Efficiency Upflow Horizontal and Downflow Gas Furnaces, Efficiency Upflow Horizontal and Downflow Gas Furnaces, Upflow Horizontal and Downflow Gas Furnaces, Horizontal and Downflow Gas Furnaces, Downflow Gas Furnaces, Gas Furnaces, Furnaces |