NuTone-LOGO

NuTone FG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces

NuTone-FG7S-(A-and-K-Series)-High-Efficiency-Upflow-Horizontal-and-Downflow-Gas-Furnaces-PRODUCT

Technical Specifications

  • Model: FG7S (A and K Series)
  • Type: High Efficiency Upflow/Horizontal and Downflow Gas
    Furnaces
  • Induced Draft
  • 80+ AFUE
  • Input: 45,000 – 126,000 Btuh

Features and Benefits

  • GAS FURNACE COMPONENTS:
    • Blower Assembly
    • Blower Door Switch
    • Burner Assembly
    • Control Board
    • Flame Sensor
    • Gas Manifold
    • Gas Valve
    • Igniter
    • Inducer
    • Insulated Combustion Tube (Downflow Models)
    • Low Voltage Transformer
    • Main Air Limit Switch
    • Pressure Switch
    • Roll-Out Switch(s)

Dimensions

A Series

Model #’s A Dimension B Dimension C Dimension D Dimension
045-23A 12 12 21 14
054-23A 12 12 15 16
072-24B 15 16 21 14
090-24B 15 16 19 19
072-35C 21 14 19 19
090-35C 21 14 22 23
108-35C 21 19 22 23
126-45D 23 19 22 23

K Series

Model #’s A Dimension B Dimension C Dimension D Dimension
054-23A 12 12 21 14
072-24B 15 16 21 14
090-24B 15 16 19 19
108-35C 21 14 19 19
126-45D 22 23 19 19

Blower Performance – FG7SA Model Number

Heating Input (Btuh) Motor Speed External Static Pressure (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
45,000 High* 1260 1205 1145 1080 1025 960 890 825
Med-High 955 825
Med-Low** 950 800

Product Usage Instructions

FAQ

Q: Where can the high-efficiency gas furnace be installed?
A: The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet.

Q: Is the gas furnace design certified?
A: Yes, the gas furnace design is certified by CSA for application in Canada and the United States.

TECHNICAL SPECIFICATIONS

FG7S (A and K Series)
High-Efficiency Upflow/Horizontal and
Downflow Gas Furnaces
Induced Draft – 80+ AFUE
Input 45,000 – 126,000 Btuh
The high-efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.

FEATURES and BENEFITS

  • 100% fired and tested: All units and each component are tested on the manufacturing line.
  • Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent-free.
    • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
    • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
    • 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
    • 30 second post purge: Increases life of heat exchanger.
    • Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology.
    • Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
    • High static blowers: All models equipped with high static blowers.
    • 90 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil.
    • Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
    • High efficiency blower kits: Maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized.
    • Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection.
    • LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
    • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
    • Integrated control board: Incorporates connections for electronic air cleaner and humidifier.
    • Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws.
    • Blower Compartment: Insulated for ultra quiet operation.
    • Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

GAS FURNACE COMPONENTS

NuTone-FG7S-(A-and-K-Series)-High-Efficiency-Upflow-Horizontal-and-Downflow-Gas-Furnaces-1

  1. Blower Assembly
  2.  Blower Door Switch
  3.  Burner Assembly
  4. Control Board
  5. Flame Sensor
  6. Gas Manifold
  7. Gas Valve
  8. Igniter
  9. Inducer
  10.  Insulated Combustion Tube wnflow Models)
  11. Low Voltage Transformer
  12. Main Air Limit Switch
  13. Pressure Switch
  14. Roll-Out Switch(s)

DIMENSIONS

NuTone-FG7S-(A-and-K-Series)-High-Efficiency-Upflow-Horizontal-and-Downflow-Gas-Furnaces-2

FG7SA 80+ High Efficiency Upflow/Horizontal Series

NuTone-FG7S-(A-and-K-Series)-High-Efficiency-Upflow-Horizontal-and-Downflow-Gas-Furnaces-3

FG7SK 80+ High Efficiency Downflow Series

BLOWER PERFORMANCE – FG7SA

 

Model Number

Heating Input (Btuh)  

Motor Speed

External Static Pressure (Inches Water Column)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise
    High* 1260 26 1205 28 1145 29 1080 31 1025 33 960 35 890 37 825 40
SA045( )-23A

Bottom Return

 

45,000

Med-High

Med-Low**

955

825

35

40

950

800

35

42

940

760

35

44

935

730

36

46

925

690

36

48

860

650

39

51

800

600

42 725

530

46
    Low 655 51 630 53 610 55 580 550 520 480 435
    High* 1350 25 1290 26 1225 27 1155 29 1100 30 1025 33 950 35 885 38
SA045( )-23A

Side Return

 

45,000

Med-High

Med-Low**

1025

885

33

38

1015

855

33

39

1005

815

33

41

1000

780

33

43

990

740

34

45

920

695

36

48

855

640

39

52

775

565

43
    Low 700 48 675 49 655 51 620 590 555 515 465
    High* 1260 32 1205 33 1145 35 1080 37 1025 39 960 42 890 45 825 48
SA054( )-23A

Bottom Return

 

54,000

Med-High

Med-Low**

955

825

42

48

950

800

42

50

940

760

43

53

935

730

43

55

925

690

43 860

650

47 800

600

50 725

530

55
    Low 655 630 610 580 550 520 480 435
    High* 1350 30 1290 31 1225 33 1155 35 1100 36 1025 39 950 42 885 45
SA054( )-23A

Side Return

 

54,000

Med-High

Med-Low**

1025

885

39

45

1015

855

39

47

1005

815

40

49

1000

780

40

51

990

740

40

54

920

695

43 855

640

47 775

565

52
    Low 700 675 655 620 590 555 515 465
    High* 1685 32 1640 33 1605 33 1565 34 1515 35 1475 36 1415 38 1345 40
SA072( )-24B

Bottom Return

 

72,000

Med-High

Med-Low**

1330

1175

40

45

1295

1155

41

46

1275

1125

42

47

1245

1100

43

48

1215

1075

44

50

1185

1045

45

51

1135

1010

47

53

1070

955

50

56

    Low 930 57 895 60 885 60 850 825 800 770 740
    High* 1770 30 1720 31 1685 32 1645 32 1590 34 1550 34 1485 36 1415 38
SA072( )-24B

Side Return

 

72,000

Med-High

Med-Low**

1400

1235

38

43

1360

1215

39

44

1340

1180

40

45

1310

1155

41

46

1275

1130

42

47

1245

1100

43

48

1190

1060

45

50

1125

1005

47

53

    Low 975 55 940 57 930 57 890 60 865 840 810 775
    High* 1610 41 1575 42 1530 44 1485 45 1440 46 1385 48 1340 50 1275 52
SA090( )-24B

Bottom Return

 

90,000

Med- High**

Med-Low

1295

1155

51

58

1260

1130

53

59

1235

1100

54

61

1220

1070

55 1175

1035

57 1135

1015

59 1095

965

1015

920

    Low 880 860 830 800 765 740 675 660
    High* 1690 39 1655 40 1610 41 1560 43 1510 44 1455 46 1405 47 1340 50
SA090( )-24B

Side Return

 

90,000

Med- High**

Med-Low

1360

1215

49

55

1325

1190

50

56

1300

1155

51

58

1280

1125

52

59

1235

1090

54 1190

1065

56 1150

1015

58 1065

965

    Low 925 900 870 840 800 775 710 695
    High* 1950 1865 1790 1715 1630 1550 1475 36 1390 38
SA072( )-35C

Bottom Return

 

72,000

Med-High

Med-Low**

1860

1300

1780

1240

1710

1200

1635

1160

1575

1120

1500

1065

36

50

1415

995

38

54

1325

910

40

59

41 43 44 46 48
    Low 1165 46 1115 48 1060 50 1025 52 985 54 940 57 890 60 825 65
    High* 2030 1940 1860 1785 1695 1615 1535 35 1445 37
SA072( )-35C

Side Return

 

72,000

Med-High

Med-Low**

1935

1350

1850

1290

1780

1250

1700

1205

1340

1165

40

46

1560

1110

1470

1035

36

52

1380

945

39

56

40 41 43 44 48
    Low 1215 44 1160 46 1105 48 1065 50 1025 52 980 54 925 58 860 62
 

Model Number

 

Heating Input (Btuh)

 

Motor Speed

External Static Pressure (Inches Water Column)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise
 

SA072( )-35C

Side + Bottom or 2 Sides

 

 

72,000

High* Med-High Med-Low**

Low

2050

1955

1365

1225

1960

1870

1300

1170

1880

1800

1260

1115

1800

1715

1220

1075

1710

1655

1175

1035

1630

1575

1120

985

1550

1485

1045

935

1460

1390

955

865

37

38

56

62

36

51

57

39

44

41

46

42

48

44

50

45

52

48

54

    High* 1940 1860 36 1790 37 1710 39 1625 41 1540 43 1450 46 1355 49
SA090( )-35C

Bottom Return

 

90,000

Med-High**

Med-Low

1820

1290

37

52

1760

1245

38

54

1695

1200

39

56

1620

1155

41

58

1545

1110

43

60

1466

1060

45

63

1380

995

48 1280

915

52
    Low 1145 58 1110 60 1070 62 1035 64 1000 950 905 835
    High* 2020 1935 1860 36 1780 37 1690 39 1600 42 1510 44 1410 47
SA090( )-35C

Side Return

 

90,000

Med-High**

Med-Low

1895

1345

35

50

1830

1295

36

51

1765

1250

38

53

1685

1200

40

56

1610

1155

41

58

1525

1100

44

61

1435

1035

46

64

1330

950

50
    Low 1190 56 1155 58 1115 60 1075 62 1040 64 980 940 870
 

SA090( )-35C

Side + Bottom or 2 Sides

 

 

90,000

High* Med-High** Med-Low

Low

2040

1910

1355

1205

1955

1850

1310

1165

1880

1780

1260

1125

35

37

53

59

1795

1700

1215

1085

37

39

55

61

1705

1625

1165

1050

39

41

57

63

1620

1540

1115

1000

41

43

60

1525

1450

1050

950

44

46

63

1425

1345

960

875

47

50

35

49

55

36

51

57

    High* 2205 36 2150 37 2095 38 2030 39 1970 41 1900 42 1830 44 1740 46
SA108( )-35C

Bottom Return

 

108,000

Med-High**

Med-Low

2050

1700

39

47

1995

1680

40

48

1955

1645

41

49

1895

1610

42

50

1840

1565

43

51

1775

1525

45

52

1700

1460

47

55

1610

1375

50

58

    Low 1390 58 1370 58 1355 59 1320 61 1300 62 1270 63 1225 65 1175
    High* 2295 35 2235 36 2180 37 2110 38 2050 39 1975 41 1900 42 1810 44
SA108( )-35C

Side Return

 

108,000

Med-High**

Med-Low

2130

1770

38

45

2075

1750

39

46

2035

1710

39

47

1970

1675

41

48

1915

1630

42

49

1845

1585

43

50

1765

1520

45

53

1675

1430

48

56

    Low 1445 55 1425 56 1410 57 1375 58 1350 59 1320 61 1275 63 1225 65
    High* 2315 35 2260 35 2200 36 2130 38 2070 39 1995 40 1925 42 1825 44
SA108( )-35C

Side + Bottom

 

108,000

Med-High** Med-Low 2155

1785

37

45

2095

1765

38

45

2055

1725

39

46

1990

1690

40

47

1930

1645

41

49

1865

1600

43

50

1785

1535

45

52

1690

1445

47

55

or 2 Sides   Low 1460 55 1440 56 1425 56 1385 58 1365 59 1335 60 1285 62 1235 65
    High* 2255 41 2200 42 2125 44 2065 45 2010 46 1935 48 1855 50 1755 53
SA126( )-45D

Bottom only or 2 openings

 

126,000

Med-High**

Med-Low

2075

1720

45

54

2025

1695

46

55

1970

1655

47

56

1940

1630

48

57

1875

1580

50

59

1810

1520

52

61

1750

1455

53

64

1680

1390

56

67

1310 1300 1260 1230
    Low 1360 69 1375 68 1365 68 1315
    High* 2230 42 2180 43 2105 44 2045 46 1990 47 1915 49 1835 51 1740 54
SA126( )-45D

Side Return

 

126,000

Med-High**

Med-Low

2055

1705

45

55

2005

1680

47

56

1950

1640

48

57

1920

1615

49

58

1855

1565

50

60

1790

1505

52

62

1735

1440

54

65

1665

1375

56

68

    Low 1345 69 1360 69 1350 69 1300 1230 1290 1250 1220
 

Model Number

 

Heating Input (Btuh)

 

Motor Speed

External Static Pressure (Inches Water Column)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise
 

 

SK054( )-23A

 

 

54,000

High* Med-High Med-Low**

Low

1375

1155

790

650

29

35

51

1340

1130

775

640

30

35

52

1300

1110

765

630

31

36

52

1270

1085

750

610

31

37

53

1225

1055

730

590

33

38

55

1175

1015

700

565

34

39

1115

975

665

530

36

41

1035

910

610

480

39

44

 

 

SK072( )-24B

 

 

72,000

High* Med-High Med-Low**

Low

1610

1295

1155

910

33

41

46

59

1590

1275

1135

885

34

42

47

60

1575

1260

1115

860

34

42

48

1560

1250

1095

835

34

43

49

1540

1220

1065

810

35

44

50

1495

1195

1040

785

36

45

51

1460

1170

1015

765

37

46

53

1415

1120

980

735

38

48

54

 

 

SK090( )-24B

 

 

90,000

High* Med-High Med-Low**

Low

1675

1330

1180

940

40

50

56

1655

1315

1165

925

40

51

57

1640

1300

1150

900

41

51

58

1620

1280

1135

880

41

52

59

1590

1255

1115

850

42

53

60

1560

1230

1090

825

43

54

61

1520

1200

1060

795

44

56

63

1475

1150

1010

760

45

58

66

 

 

SK108( )-35C

 

 

108,000

High* Med-High Med-Low**

Low

2395

2190

1785

1145

33

37

45

2335

2135

1770

1110

34

37

45

2285

2115

1740

1070

35

38

46

2230

2080

1725

1035

36

38

46

2200

2030

1685

1000

36

39

47

2140

1975

1645

950

37

41

49

2080

1915

1615

905

38

42

50

2000

1810

1565

835

40

44

51

 

 

SK126( )-45D

 

 

126,000

High* Med-High Med-Low**

Low

2445

2195

1795

1480

38

43

52

63

2395

2170

1780

1475

39

43

52

63

2385

2140

1770

1450

39

44

53

64

2330

2120

1760

1440

40

44

53

65

2275

2090

1725

1440

41

45

54

65

2225

2030

1690

1415

42

46

55

2130

1975

1655

1405

44

47

56

2015

1855

1610

1375

46

50

58

NOTES:
Can be C or N

  1. Two openings are required for airflows above 1600 CFM if filter(s) is(are) adjacent to furnace.
  2. Factory Set Cooling Speed 2. Temperature rises in the table are approximate. Actual temperature rises may vary.
  3. Factory Set Heating Speed 3. Temperature rises shaded in gray are not recommended.

NOTES:

Can be C or N

  1. Factory Set Cooling Speed 1. Temperature rises in the table are approximate. Actual temperature rises may vary.
  2. Factory Set Heating Speed 2. Temperature rises shaded in gray are not recommended.

MODEL IDENTIFICATION CODE

NuTone-FG7S-(A-and-K-Series)-High-Efficiency-Upflow-Horizontal-and-Downflow-Gas-Furnaces-4

SPECIFICATIONS

FG7SA MODEL NUMBERS -045-23A -054-23A -072-24B -090-24B -072-35C -090-35C -108-35C -126-45D
Input – Btuh (a) 45,000 54,000 72,000 90,000 72,000 90,000 108,000 126,000
Heating Capacity – Btuh 36,000 43,200 57,600 72,000 57,600 72,000 86,400 100,800
AFUE 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0
Blower D x W 10 x 6 10 x 6 11x 8 11 x 8 10 x 10 10 x 10 11 x 10 11 x 10
Motor H.P. – Speed – Type 1/3 – 4 – PSC 1/3 – 4 – PSC 1/2 – 4 – PSC 1/2 – 4 – PSC 1/2 – 4 – PSC 1/2 – 4 – PSC 1.0 – 4 – PSC 1.0 – 4 – PSC
Motor FLA 4.80 4.80 8.20 8.20 7.50 7.50 13.75 13.75
Rated Ext. SP – In. W.C. 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Temperature Rise Range – ºF 30-60 30-60 35-65 35-65 35-65 35-65 40-70 40-70
Shipping Weights 100lbs 100lbs 110lbs 115lbs 115lbs 120lbs 125lbs 145lbs
FG7SK MODEL NUMBERS -054-23A -072-24B -090-24B -108-35C -126-45D
Input – Btuh (a) 54,000 72,000 90,000 108,000 126,000
Heating Capacity – Btuh 43,200 57,600 72,000 86,400 100,800
AFUE 80.0 80.0 80.0 80.0 80.0
Blower D x W 10 x 6 11 x 8 11 x 8 11 x 10 11 x 10
Motor H.P. – Speed – Type 1/3 – 4 – PSC 1/2 – 4 – PSC 1/2 – 4 – PSC 3/4 – 4 – PSC 1.0 – 4 -PSC
Motor FLA 4.80 8.20 8.20 13.75 13.75
Rated Ext. SP – In. W.C. 0.5 0.5 0.5 0.5 0.5
Temperature Rise Range – ºF 30-60 35-65 35-65 40-70 40-70
Shipping Weights 100lbs 110lbs 115lbs 125lbs 145lbs

ACCESSORIES

FG7S (A, K) KITS
Description SKU
“A” Cabinet fixed speed, high efficiency, FSHE 904872
“B” Cabinet fixed speed, high efficiency, FSHE 904873
“C” Cabinet fixed speed, high efficiency, FSHE 904874
“D” Cabinet fixed speed, high efficiency, FSHE 904875
“A” Cabinet variable speed, high efficiency, VSHE 904876
“B” Cabinet variable speed, high efficiency, VSHE 904877
“C” Cabinet variable speed, high efficiency, VSHE 904878
“D” Cabinet variable speed, high efficiency, VSHE 904879
“A” Cabinet downflow sub base kit 902974
“B”, “C”, “D” Cabinet downflow sub base kit 904911
U.S. LP Conversion kit (0 to 10,000 ft.) 904914
Canada LP Conversion kit (0 to 4,500 ft.) 904915
Bottom return filter 20 per box, “A” cabinet 903088
Bottom return filter 20 per box, “B” cabinet 904916
Bottom return filter 20 per box, “C” cabinet 904917
Bottom return filter 20 per box, “D” cabinet 904918
Side return filter kit 541036

GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (08/2016)

www.nutonehvac.com
NuTone® trademark used under license. © Nortek Global HVAC, LLC. All Rights Reserved.

Documents / Resources

NuTone FG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces [pdf] Owner's Manual
FG7S A and K Series High Efficiency Upflow Horizontal and Downflow Gas Furnaces, FG7S A and K Series, High Efficiency Upflow Horizontal and Downflow Gas Furnaces, Efficiency Upflow Horizontal and Downflow Gas Furnaces, Upflow Horizontal and Downflow Gas Furnaces, Horizontal and Downflow Gas Furnaces, Downflow Gas Furnaces, Gas Furnaces, Furnaces