The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.
FEATURES and BENEFITS
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
- 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
- 30 second post purge: Increases life of heat exchanger.
- Hot surface igniter: Innovative application of a silicon nitride igniter.
- High static blowers: All models equipped with high static blowers.
- 90 second cooling cycle blower-off delay (TDR): Increases cooling performance.
- Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances.
- High efficiency blower kits: Maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized.
- Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection.
- LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
- Integrated control board: Incorporates connections for electronic air cleaner and humidifier.
- Two piece door design: Enhances furnace appearance and uses captured screws to prevent loose door screws.
- Meets Title 24 Standards: Min. 350 CFM/Ton, .58 watts/CFM and ≤ 2% cabinet leakage.
GAS FURNACE COMPONENTS
- Blower Assembly
- Blower Door Switch
- Burner Assembly
- Control Board
- Flame Sensor
- Gas Manifold
- Gas Valve
- Igniter
- Inducer
- Insulated Combustion Tube (Downflow Models)
- Low Voltage Transformer
- Main Air Limit Switch
- Pressure Switch
- Roll-Out Switch(s)
DIMENSIONS
J801X*U Model #’s | Dimension “A” | Dimension “B” | Dimension “C” | Dimension “D” |
045AU |
14 1/4 |
10 3/4 |
12 5/8 |
12 7/8 |
054AU | ||||
072BU |
17 1/2 |
11 3/4 |
15 7/8 |
16 1/8 |
090BU | ||||
072CU |
21 |
14 |
19 3/8 |
19 7/8 |
090CU | ||||
108CU | ||||
126DU | 24 1/2 | 15 1/4 | 22 7/8 | 23 1/8 |
J801X*D Model #’s | Dimension “A” | Dimension “B” | Dimension “C” | Dimension “D” |
054AD | 14 1/4 | 10 3/4 | 12 5/8 | 12 7/8 |
072BD |
17 1/2 |
11 3/4 |
15 7/8 |
16 1/8 |
090BD | ||||
108CD | 21 | 14 | 19 3/8 | 19 5/8 |
126DB | 24 1/2 | 15 1/4 | 22 7/8 | 23 1/8 |
MODEL IDENTIFICATION CODE
SPECIFICATIONS
J801X*U MODEL NUMBERS | 045AU | 054AU | 072BU | 090CU | 108CU | 126CU |
Input – BTUH | 45,000 | 54,000 | 72,000 | 90,000 | 108,000 | 126,000 |
Heating Capacity – BTUH | 36,000 | 43,200 | 57,600 | 72,000 | 86,400 | 100,800 |
AFUE | 80.0 | 80.0 | 80.0 | 80.0 | 80.0 | 80.0 |
Motor H.P. – Speed – Type | 1/2 – 5 – ECM | 1/2 – 5 – ECM | 3/4 – 5 – ECM | 3/4 – 5 – ECM | 1 – 5 – ECM | 1 – 5 – ECM |
Motor FLA | 6.4 | 6.4 | 8.8 | 8.8 | 11.5 | 11.5 |
Rated Ext. SP – In. W.C. | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Rise Range – F | 30-60 | 30-60 | 30-60 | 35-65 | 35-65 | 40-70 |
Shipping Weights (lbs) | 95 | 95 | 110 | 134 | 136 | 147 |
J801X*D MODEL NUMBERS | 054AU | 072BD | 090BD | |||
Input – Btuh (a) | 54,000 | 72,000 | 90,000 | |||
Heating Capacity – Btuh | 43,000 | 58,000 | 72,000 | |||
AFUE | 80.0 | 80.0 | 80.0 | |||
Motor H.P. – Speed – Type | 1/2 – 5 – ECM | 3/4 – 5 – ECM | 3/4 – 5 – ECM | |||
Motor FLA | 6.4 | 8.8 | 8.8 | |||
Rated Ext. SP – In. W.C. | 0.5 | 0.5 | 0.5 | |||
Temperature Rise Range – F | 30-60 | 35-65 | 35-65 | |||
Shipping Weights (lbs) | 102 | 110 | 115 |
ACCESSORIES
J801X*U AND J801X*D KITS | |
Description | SKU |
“A” Cabinet downflow sub base kit | 902974 |
“B”, “C”, “D” Cabinet downflow sub base kit | 904911 |
U.S. LP Conversion kit (0 to 10,000 ft.) | 904914 |
Bottom return filter 20 per box, “A” cabinet | 903088 |
Bottom return filter 20 per box, “B” cabinet | 904916 |
Bottom return filter 20 per box, “C” cabinet | 904917 |
Bottom return filter 20 per box, “D” cabinet | 904918 |
Side return filter kit | 541036 |
Furnace Twinning Kit | 1010035 |
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (07/2022)
Documents / Resources
![]() |
OXBOX J801X Series High Efficiency Upflow-Horizontal and Downflow Gas Furnaces [pdf] Installation Guide J801X Series High Efficiency Upflow-Horizontal and Downflow Gas Furnaces, J801X Series, High Efficiency Upflow-Horizontal and Downflow Gas Furnaces, Upflow-Horizontal and Downflow Gas Furnaces, Horizontal and Downflow Gas Furnaces, Downflow Gas Furnaces, Gas Furnaces, Furnaces |