NOTIFIER INSPIRE™ CONFIGURATION GUIDE
REV A
10/4/2022
CAB-5 Series Backbox Options
CAB-5 Series Door Options
(“B” after any part number below will result in a solid “blank” door)
Note: All doors shown hinged left but may be hinged right flipping the trim and lock.
CAB-5 Series Cabinet Mounted Chassis
CPU-N16LND/CPU-N16LD
Includes Inspire Panel Core, CAB-5 Chassis, Power Supply, and SLM-318 Card Chassis supports up to 6 Cards (2 wide x 3 deep)
* CPU-N16LD includes the 10” display (not shown)
PMB-AUX
Includes CAB-5 Chassis and Power Supply Chassis supports up to 6 Cards (2 wide x 3 deep)
C5A-M
Includes CAB-5 Audio Chassis, Audio Well and Microphone Chassis supports DVC and up to 2 Cards (Limited Access) Audio Well supports optional TELH-1 Telephone (DVC-EM and DVC-KDB ordered separately) Mounts in Rows 1, 2, or 3 (adjustable for Rows 1 or 3)
C5A-NW
CAB-5 Audio Chassis Only
Chassis mounts DVC and up to 2 Cards
(DVC-EM and DVC-KDB must be ordered separately)
Mounts in Rows 1, 2, or 3 (adjustable for Rows 1 or 3)
CHS-ADP
CAB-5 Adaptor for mounting CAB-4 series chassis or equipment (i.e. CHS-4L, CHS-6, etc.)
CAB-5 Series Dress Panels
DP-T2A
Mounts 10” Display with 2 ACM-30 Locations (or ABP-1 Blank Covers)
DPA-C5
Used to Cover C5A-M
DPA-2A5
Used with C5A-NW with 2 ACM-30 Locations (or ABP-1 Annunciator Blank Covers)
DP-4A
Mounts 4 ACM-30 Annunciators (or ABP-1 Annunciator Blank Covers)
DP-BLN
Blank Dress Panel
BP-5
Covers Bottom Section of CAB-5 Enclosures
CAB-4 Series Retrofit Chassis
CPU-N16-RTO
Includes Inspire Panel Core, CAB-4 Chassis, Power Supply, 10” Display and SLM-318 Card Chassis supports up to 6 Cards (2 wide x 3 deep) (Display not shown)
PMB-AUX-RTO
Includes CAB-4 Chassis and Power Supply Chassis supports up to 6 Cards (2 wide x 3 deep)
CAB-4 Series Retrofit Dress Panels
DP-T2A-CB4
Mounts 10” Display with 2 ACM-30 Locations (or APD-1 Annunciator Blank Covers)
DP-4A-CB4
Mounts 4 ACM-30 Annunciators (or ADP-1 Annunciator Blank Covers)
NOTIFIER INSPIRE Annunciator Modules and SLC
ACM-30
Provides 30 programmable capacitive-touch control points and 60 mappable multi-colored LEDs.
80 ACM-30s per CPU, 10 Router Addresses, 15 Peripherals per Router Options Order ACM-30CBL (includes four 6” and one 48” ribbon cable ) when configuring ACM-30s as Peripherals
* Only DP-T2A-CB4 or DP-4A-CB4 retrofit dress panels are supported for CAB-4 Series.
ABP-1
Covers unused ACM-30 position
Provides mounting options for cards (limited).
* Only DP-T2A or DP-4A-CB4 retrofit dress panels are supported for CAB-4 Series.
SLM-318
Provides SLC Communications to Inspire Series panels for up to 159 Detectors and 159 Modules via Flashscan protocol.
Up to 10 SLM-318 cards may be on a N16 Panel. More than 5 SLM-318 cards requires a PMB-AUX.
CLIP protocol may be activated via a panel license.
NOTIFIER INSPIRE Off-Premise Communication
HON-CGW-MBB
CLSS Gateway in surface-mount plastic enclosure (required for wireless/cellular communications)
Options
50160636-001: 30” NUP Cable and Notifier lock and key set
32351718-001: 10’ NUP Cable
CCM-ATT-HON: AT&T Cellular Communication Module
CCM-VZ-HON: Verizon Cellular Communication Module
CHS-CGW
Use CHS-CGW for mounting the gateway on the CPU-N16 or PMB-AUX chassis only*
* For wired sole-path IP communication only
Note: Wireless/cellular communication is NOT supported within metal enclosures.
Order the HON-CGW-MBB separately and remove the gateway from the plastic enclosure.
Must be mounted in the far right position of CPU-N16 or PMB-AUX chassis and does not support cards stacked in front. If in the 3rd card position, do not mount ACM-30 in front on dress panel.
CGW-DACT-NF
POTS Dialer which comes with Gateway board, POTS card, and mounting chassis for mounting in any standard card location. Requires 2 stacked card locations.
Gateway board is dedicated for dialer control and will not function as a standard CLSS gateway.
Must be mounted in the far right position of chassis and does not support cards stacked in front.
High-Speed Network Cards
HS-NCM-MFSF / HS-NCM-SF / HS-NCM-MF
HS-NCM-MFSF provides one Multi-Mode LC port and one Single-Mode fiber LC port for High-Speed network communication.
HS-NCM-SF provides two Single-Mode fiber LC ports for High-Speed network communication.
HS-NCM-MF provides two Multi-Mode fiber LC ports for High-Speed network communication.
Each HS-NCM card allows for connection to up to 2 network nodes via NUP connectors.
HS-NCM-WMF-2 / HS-NCM-WSF-2
HS-NCM-WMF-2 provides one Multi-Mode fiber LC port and one wired port for High-Speed network communication.
HS-NCM-WSF-2 provides one Single-Mode fiber LC port and one wired port for High-Speed network communication.
Each HS-NCM card allows for connection to up to 2 network nodes via NUP connectors.
HS-NCM-W-2
HS-NCM-WMF-2 provides two wired LC ports for High-Speed network communication.
Each HS-NCM card allows for connection to up to 2 network nodes via NUP connectors.
Standard Speed Network Cards
NCM-W
NCM-W provides two wired ports for Standard-Speed network communications.
Each NCM-W card allows for connection to 1 network node via one NUP connector.
NCM-F
NCM-F provides two Multi-Mode Fiber ST ports (Tx and Rx for each port) for Standard-Speed network communications.
Each NCM-F card allows for connection to 1 network node via one NUP connector.
NOTIFIER INSPIRE Dual Annunciator Display Cabinet (ABB-2)
Remote ABB-2 Enclosure shown with Two ACM-30 annunciators (ordered separately)
Backbox support mounting a single High-Speed Network Card or two standard Network cards
NOTIFIER INSPIRE NCD Cabinet (NBB-2)
Remote ABB-2 Enclosure shown with a NCD Display and a High-Speed Network Card (ordered separately)
Interior View (Shown with HS-NCM-W-2)
Backbox support mounting a single High-Speed Network Card or two standard Network cards
NOTIFIER INSPIRE Single Annunciator Display Cabinet (ABB-1) #1
Remote ABB-1 Enclosure with an ACM-30 annunciator (ordered separately)
Backbox support mounting a single standard Network
ONYX Remote NCD Cabinet (ABS-TD)
Remote ONYX NCD Enclosure shown with NCD display and Standard NCM-F Card (ordered separately)
Backbox support mounting a single Standard Network card only in the left position
NOTIFIER INSPIRE Remote Location Display (RLD)
NOTIFIER INSPIRE PANEL LICENSING
NOTIFIER INSPIRE N16 Panel Includes:
250 General Zones
250 Logic Zones
8 Custom Action Buttons
Flashscan SLC Protocol
Additional functionality may be added through one-time software licenses.
- N16-CAC Adds 8 Custom Action Buttons (32 maximum per N16 Panel)
- N16-CLIP Adds CLIP SLC Protocol for a single SLM-318 Card
- N16-GZN Adds 250 General Zones (2000 maximum per N16 Panel)
- N16-LGZ Adds 250 Logic Zones (2000 maximum per N16 Panel)
- N16-NWD Enables Display of Network Events on a N16 Panel for more than 2 nodes
- N16-UZC Enables Zone Coding on a N16 Panel
NCD Network Display Includes:
250 Logic Zones
8 Custom Action Buttons
- NCD-CAC Adds 8 Custom Action Buttons (32 maximum per NCD)
- NCD-LGZ Adds 250 Logic Zones (2000 maximum per NCD)
SPECIAL RETROFIT CONSIDERATION:
NFS2-3030 Voice retrofit where existing application includes CA-2 and DPA-2
INSPIRE Retrofit
(Requires 1 available Row)
Existing Equipment not shown
QUANTITY | PART NO | DESCRIPTION |
1 | CA-1 | CHASSIS, DVC, ONE ROW |
1 | CFFT-1 | SINGLE NEW CHASSIS FOR MOUNTING FIREFIGHTER’S TELEPHONE. INCLUDES CFFT-1 CHASSIS, PHONE WELL, TELH-1 AND HARDWARE. ORDER DP-CFFT DRESS PLATE SEPARATELY |
1 | CMIC-1 | CHASSIS WITH PAGING MICROPHONE WITH WELL; USED WITH CA-1 |
1 | DPA-1 | DRESS PLATE, DVC, ONE ROW |
1 | DP-CFFT | DRESS PLATE USED WITH CFFT-1 |
As Required | ABP-1 | ANNUNCIATOR BLANK PLATE, FOR CAB-5 |
1 | DP-T2A-CB4 | DRESS PANEL; MOUNTS 10″ TOUCHSCREEN DISPLAY AND 2 ACM-30 IN CAB-4 |
1 | 50160636-001 | CLSS GATEWAY KIT. INCLUDES 30″ NUP CABLE AND NOTIFIER LOCK AND KEY SET |
Choose 1 | CCM-ATT-HON | CLSS CELLULAR COMMUNICATION MODULE FOR ATT |
CCM-VZ-HON | CLSS CELLULAR COMMUNICATION MODULE FOR VERIZON | |
1 | HON-CGW- MBB | CLSS GATEWAY, WITH ENCLOSURE (NOTIFIER LOCK AND CABLE KIT, 50160636-001 SOLD SEPARATELY) |
As Required | ACM-30 | INSPIRE SERIES ANNUNCIATOR CONTROL MODULE CONFIGURABLE FOR ACTIVATION AND INDICATION |
1 | CPU-16-RTO | N16X INTELLIGENT FIRE ALARM CONTROL PANEL; 10″ TOUCHSCREEN DISPLAY, CPU, UNIVERSAL AC INPUT POWER SUPPLY AND SIGNALING LOOP MODULE (318 DEVICES), EXPANDABLE TO 10, CHASSIS MOUNT. MOUNTS IN CAB-4 |
As Required | SLM-318 | SIGNALING LOOP MODULE SUPPORTS 318 DEVICES PER LOOP MODULE. |
**BATTERY BOXES AND SYSTEM BATTERIES ARE NOT INCLUDED AND SHOULD BE SELECTED BASED
Sample Configuration #1— NOTIFIER INSPIRE N16x Voice
FACU With 7 SLC Loops, 1000 General Zones, 750 Logic Zones, 50 Watts of 70Vrms Speaker Power and Backup, Multimode Fiber Network, and CLSS cellular/wireless connectivity.
Sample Configuration #1—NOTIFIER INSPIRE N16x Voice BOM
FACU With 7 SLC Loops, 1000 General Zones, 750 Logic Zones, 50 Watts of 70Vrms Speaker Power and Backup, Multimode Fiber Network, and CLSS cellular/wireless connectivity.
QUANTITY | PART NO | DESCRIPTION |
1 | SBB-E5 | CAB-5 STANDARD BACK BOX SIZE E, FIVE ROW |
1 | DR-E5 | E SIZE DOOR, LOCK & KEYS FOR CAB-5 |
1 | DP-T2A | DRESS PANEL; 10″ TOUCHSCREEN DISPLAY AND 2 ANNUNCIATORS FOR CAB-5 |
1 | DPA-05 | DRESS PLATE FOR C5A-M; MICROPHONE AND TELEPHONE OPENING, FOR CAB-5 |
1 | DP-4A | DRESS PANEL; MOUNTS 4 ACM-30 ANNUNCIATORS, FOR CAB-5 |
2 | DP-BLN | DRESS PANEL BLANK; COVERS UNUSED CABINET ROW FOR CAB-5 |
1 | BP-5 | BATTERY DRESS PANEL FOR CAB-5 SERIES, CAB-5 |
2 | ACM-30 | INSPIRE SERIES ANNUNCIATOR CONTROL MODULE CONFIGURABLE FOR ACTIVATION AND INDICATION |
4 | ABP-1 | ANNUNCIATOR BLANK PLATE, FOR CAB-5 |
1 | HS-NCM-MF | HIGH-SPEED NETWORK COMMUNICATIONS MODULE, FIBER-OPTIC CABLE INTERFACE (MULTI-MODE). |
6 | SLM-318 | SIGNALING LOOP MODULE SUPPORTS 318 DEVICES PER LOOP MODULE. (1 SLM-318 is included with CPU-N16LD) |
1 | CPU-N16LD | N16X INTELLIGENT FIRE ALARM CONTROL PANEL; 10″ TOUCHSCREEN DISPLAY, CPU, UNIVERSAL AC INPUT POWER SUPPLY AND SIGNALING LOOP MODULE (318 DEVICES), EXPANDABLE TO 10, CHASSIS MOUNT. FOR CAB-5 SERIES |
1 | CSA-M | DVC CHASSIS, SINGLE ROW FOR MOUNTING DVC, MICROPHONE AND FIREFIGHTER’S TELEPHONE. INCLUDES: WELL, MIC-1 AND HARDWARE. ORDER TELH-1 SEPARATELY. FOR CAB-5 |
1 | DVC-EM | DIGITAL VOICE COMMAND, EXTENDED MEMORY |
2 | DS-FM | CONVERTS ONE DAX OR DAA2 DAL PORT TO MULTI-MODE FIBER (One installed on DVC and one installed on DAA2-5070) |
1 | DVC-KDB | DIGITAL VOICE COMMAND, KEYPAD |
1 | TELH-1 | FIREFIGHTER’S TELEPHONE HANDSET ONLY |
1 | PMB-AUX | AUXILIARY POWER SUPPLY, 6 AMPS, UNIVERSAL AC INPUT, ON CHASSIS FOR CAB-5 |
1 | CHS-ADP | ADAPTER PLATE TO MOUNT CAB-4 CHASSIS IN CAB-5 |
1 | DAA2-5070 | DIGITAL AMPLIFIER 50W, 70V, 120 VAC |
1 | BDA-70V | BACK-UP DIGITAL AMPLIFIER FOR 70 VOLT DAX OR DAA2 SERIES |
1 | CHS-BH1 | CHASSIS, 12AH BATTERY HOLDER, FOR USE WITH DAA- NUMBERS |
1 | BAT-12120-BP | FOUR (4) BAT-12120 BAT-12120 (12V, 12AH) |
3 | N16•GZN | PANEL LICENSE – ADD 250 GENERAL ZONES FOR N16 PANEL [250 ZONES INCLUDED IN CPU. UP TO 2000 GENERAL ZONES PER CPU) |
2 | N16-LGZ | PANEL LICENSE – ADD 250 LOGIC ZONES FOR N16 PANEL [250 ZONES INCLUDED IN CPU, UP TO 2000 LOGIC ZONES PER CPU) |
1 | N16-NWD | PANEL LICENSE – ADD NETWORK DISPLAY MODE FOR N16 PANEL |
1 | 50160636-001 | CLSS GATEWAY KIT. INCLUDES 30″ NUP CABLE AND NOTIFIER LOCK AND KEY SET |
Choose 1 | CCM-ATT-HON | CLSS CELLULAR COMMUNICATION MODULE FOR ATT |
CCM-VZ-HON | CLSS CELLULAR COMMUNICATION MODULE FOR VERIZON | |
1 | HON-CGW-MBB | CLSS GATEWAY, WITH ENCLOSURE |
1 | 32351718-001 | 10′ NUP CABLE FOR CLSS GATEWAY |
**BATTERY BOX AND SYSTEM BATTERIES ARE NOT INCLUDED AND SHOULD BE SELECTED BASED
Sample Configuration #2—Retrofit CAB4 to NOTIFIER INSPIRE N16x
FACU With 10 SLC Loops, 500 General Zones, 250 Logic Zones, 16 Custom Action buttons, and Wired IP CLSS Connectivity.
Sample Configuration #2—Retrofit to NOTIFIER INSPIRE N16x BOM
FACU With 10 SLC Loops, 500 General Zones, 250 Logic Zones, 16 Custom Action buttons, and Wired IP CLSS Connectivity.
QUANTI- TY | PART NO | DESCRIPTION |
4 | ACM-30 | INSPIRE SERIES ANNUNCIATOR CONTROL MODULE CONFIGURABLE FOR ACTIVATION AND INDICATION |
2 | ABP-1 | ANNUNCIATOR BLANK PLATE, FOR CAB-5 |
9 | SLM-318 | SIGNALING LOOP MODULE SUPPORTS 318 DEVICES PER LOOP MODULE. |
1 | N16-CAC | PANEL LICENSE – ADD 8 CUSTOM ACTION BUTTONS FOR N16 (8 SOFT BUTTONS INCLUDED WITH CPU, UP TO 32 BUTTONS) |
1 | N16-GZN | PANEL LICENSE – ADD 250 GENERAL ZONES FOR N16 PANEL (250 ZONES INCLUDED IN CPU. UP TO 2000 GENERAL ZONES PER CPU) |
1 | CPU-16-RTO | N16X INTELLIGENT FIRE ALARM CONTROL PANEL; 10″ TOUCHSCREEN DISPLAY, CPU, UNIVERSAL AC INPUT POWER SUPPLY AND SIGNALING LOOP MODULE (318 DEVICES), EXPANDABLE TO 10, CHASSIS MOUNT. MOUNTS IN CAB-4 |
1 | PMB-AUX-RTO | AUXILIARY POWER SUPPLY, 6 AMPS, UNIVERSAL AC INPUT, ON CHASSIS MOUNTS IN CAB-4 |
1 | DP-T2A-CB4 | DRESS PANEL; MOUNTS 10″ TOUCHSCREEN DISPLAY AND 2 ACM-30 IN CAB-4 |
1 | DP-4A-CB4 | DRESS PANEL; MOUNTS 4 ACM-30 ANNUNCIATORS IN CAB-4 |
1 | HON-CGWM BB | CLSS GATEWAY, WITH ENCLOSURE (ENCLOSURE NOT USED IN THIS CONFIGURATION) |
1 | 32351718-001 | 10′ NUP CABLE FOR CLSS GATEWAY |
1 | CHS-CGW | HARDWARE FOR MOUNTING A CLSS GATEWAY ON THE CPU-N16 OR PMB CHASSIS. WIRELESS/CELLULAR NOT SUPPORTED. |
**BATTERY BOXES AND SYSTEM BATTERIES ARE NOT INCLUDED AND SHOULD BE SELECTED BASED
Sample Configuration #3 — NOTIFIER INSPIRE N16x
FACU With 10 SLC Loops, 2000 General Zones, 2000 Logic Zones, High-Speed Wire Network, and POTS Dialer
Sample Configuration #3 — NOTIFIER INSPIRE N16x BOM
FACU With 10 SLC Loops, 2000 General Zones, 2000 Logic Zones, High-Speed Wire Network, and POTS Dialer
QUANTI- TY | PART NO | DESCRIPTION |
4 | ABP-1 | ANNUNCIATOR BLANK PLATE, FOR CAB-5 |
1 | BP-5 | BATTERY DRESS PANEL FOR CAB-5 SERIES, CAB-5 |
1 | CHS-4L | CHASSIS, LOW PROFILE, FOR MOUNTING THE M-30, LDM. (ONLY NFS-3030/NFS-640) |
1 | CHS-6 | CHASSIS, MOUNTS UP TO 6 XP-6 MODULES IN A BB-25 OR A ROW OF THE CAB-314 SERIES CABINET; ALSO MOUNTS ACPS-610. |
2 | CHS-ADP | ADAPTER PLATE TO MOUNT CAB-4 CHASSIS IN CAB-5 |
1 | DP-4A | DRESS PANEL; MOUNTS 4 ACM-30 ANNUNCIATORS, FOR CAB-5 |
2 | DP-BLN | DRESS PANEL BLANK; COVERS UNUSED CABINET ROW FOR CAB-5 |
1 | DP-T2A | DRESS PANEL; 10″ TOUCHSCREEN DISPLAY AND 2 ANNUNCIATORS FOR CAB-5 |
1 | DR-E5 | E SIZE DOOR, LOCK & KEYS FOR CAB-5 |
1 | SBB-D5 | CAB-5 STANDARD BACK BOX SIZE D, FOUR ROW |
2 | XP1O-M | XP10 TRANSPONDER MONITOR MODULE, 10 CIRCUITS CLASS A OR B. |
4 | XP6-MA | XP6 TRANSPONDER 2-WIRE DETECTOR MONITOR MODULE; 6 CIRCUITS CLASS A OR B. |
2 | ACM-30 | INSPIRE SERIES ANNUNCIATOR CONTROL MODULE CONFIGURABLE FOR ACTIVATION AND INDICATION |
1 | CPU-N16LD | N16X INTELLIGENT FIRE ALARM CONTROL PANEL; 10″ TOUCHSCREEN DISPLAY, CPU, UNIVERSAL AC INPUT POWER SUPPLY AND SIGNALING LOOP MODULE (318 DEVICES), EXPANDABLE TO 10, CHASSIS MOUNT. FOR CAB-5 SERIES |
1 | PMB-AUX | AUXILIARY POWER SUPPLY, 6 AMPS, UNIVERSAL AC INPUT, ON CHASSIS FOR CAB-5 |
9 | SLM-318 | SIGNALING LOOP MODULE SUPPORTS 318 DEVICES PER LOOP MODULE. |
7 | N16-GZN | PANEL LICENSE – ADD 250 GENERAL ZONES FOR N16 PANEL [250 ZONES INCLUDED IN CPU. UP TO 2000 GENERAL ZONES PER CPU] |
7 | N16-LGZ | PANEL LICENSE – ADD 250 LOGIC ZONES FOR N16 PANEL [250 ZONES INCLUDED IN CPU, UP TO 2000 LOGIC ZONES PER CPU] |
1 | HS-NCM-W-2 | HIGH-SPEED NETWORK COMMUNICATIONS MODULE, TWISTED-PAIR WIRE INTERFACE. |
1 | CGW-DACT- NF |
POTS Dialer |
Sample Configuration #4 — NOTIFIER INSPIRE N16x DGP
EQ Series Enclosure containing No Display FACU With 3 SLC Loops, 500 General Zones, 250 Logic Zones, High -Speed Wire Network, 70V Digital Amplifier with Backup, and 12-Amp Strobe Expander
Sample Configuration #4 — NOTIFIER INSPIRE N16x DGP BOM
EQ Series Enclosure containing No Display FACU With 3 SLC Loops, 500 General Zones, 250 Logic Zones, HighSpeed Wire Network, 70V Digital Amplifier with Backup, and 12-Amp Strobe Expander
QUANTI- TY | PART NO | DESCRIPTION |
1 | BDA-70V | BACK-UP DIGITAL AMPLIFIER FOR 70 VOLT DAX OR DAA2 SERIES |
1 | CHS-BH1 | CHASSIS, 12AH BATTERY HOLDER, FOR USE WITH DM- NUMBERS |
1 | DAA2-5070 | DIGITAL AMPLIFIER 50W, 70V, 120 VAC |
1 | BAT-12120- BP | FOUR (4) BAT-12120 BAT-12120 (12V, 12AH) |
1 | BAT-12260- BP | TWO (2) BAT-12660 (12V, 26AH) |
1 | EQBB-D4 | EQUIPMENT BACKBOX ASSEMBLY, FOUR TIERS, BLACK. |
1 | EQDR-D4 | EQUIPMENT DOOR ASSEMBLY, VENTED, FOUR TIERS, BLACK. |
1 | CPU-16-RTO | N16X INTELLIGENT FIRE ALARM CONTROL PANEL; 10″ TOUCHSCREEN DISPLAY, CPU, UNIVERSAL AC INPUT POWER SUPPLY AND SIGNALING LOOP MODULE (318 DEVICES), EXPANDABLE TO 10, CHASSIS MOUNT. MOUNTS IN CAB-4 |
2 | SLM-318 | SIGNALING LOOP MODULE SUPPORTS 318 DEVICES PER LOOP MODULE. |
1 | N16-GZN | PANEL LICENSE – ADD 250 GENERAL ZONES FOR N16 PANEL [250 ZONES INCLUDED IN CPU. UP TO 2000 GENERAL ZONES PER CPU] |
1 | HS-NCM-W-2 | HIGH-SPEED NETWORK COMMUNICATIONS MODULE, TWISTED-PAIR WIRE INTERFACE. |
1 | HPFF12CM | 12A NAC EXPANDER, CAB-4 CHASSIS-MOUNT, INCLUDES BATTERY HOLDER FOR 12AH BATTERIES |
**BATTERY BOX AND SYSTEM BATTERIES ARE NOT INCLUDED AND SHOULD BE SELECTED BASED