Parameter Description Value
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

General Performance

Model JRMEEW
Mode of operation                           Maintained
Supply Voltage 120/347V/60Hz
Power Consumption 4.5W
Output Voltage 4.5VDC
Output Power 3.5W
Colour Temperature 6000K -7000K
Battery 3.6V 600mAh Ni-Cd Battery
Max Charge Current (mA) AC:85mA/DC:95mA
Max Discharge Current (mA) 185mA
Charging Time 24H
Discharge Time 90Min
LED 14 LEDS
Net Weight 2.58LBS
Gross Weight 2.64LBS
IP Rating IP20
Safety Classification
Certification UL Listed
Picture
Warranty                                               Five years warranty for the electrical parts and housing;

Three years warranty for battery.

OVERVIEW

NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig1

Dimensions

NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig2

Installation

LED Pictogram Sign

WARNING:
Risk of Shock. Disconnect Power before Installation.

IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS

  1. All servicing should be performed by qualified service personnel.
  2. Disconnect power at fuse or circuit breaker before installing or servicing.
  3. All electrical connections must be in accordance with local codes, ordinances and the National Electric code.
  4. Do not use outdoors.
  5. Do not let power supply cords touch hot surfaces.
  6. Do not mount near gas or electric heaters.
  7. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
  8. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
  9. Do not use this equipment for other than intended use.
  10. e caution when handling batteries. Battery acid can cause burns to the skin and eyes. If acid is spilled on the skin or eyes, flush acid with fresh water and contact a physician immediately. Avoid possible shorting.
  11. Allow battery to charge for 24 hours before first use.

SAVE THESE INSTRUCTIONS
Installation Instruction

  1. Turn off AC power.
  2. Using a flat head screwdriver, insert the blade into the two slots and pry off the front cover (see figure 4).NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig6
  3. Follow the proper mounting procedure below.

Wall mount

  • Remove the back plate from the packaging.
  • Knock out the proper hole pattern on the back plate, including the center hole, to mount to a standard junction box by supporting the area around the knock outs with two blocks of wood.
  • Remove the rear cover and diffuser.
  • Install the back plate on to the unit.
  • Feed the AC supply leads out through the center hole and make the proper connections (See step 4 and Fig.6)NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig9

Ceiling or End Mount

  • Attach the crossbar to the junction box, set the longer blade of the crossbar to touch the junction box.NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig3
  • Remove the mounting hole cover from the top or side of the unit depending on your mounting configuration (see figures 2 or 3).NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig4 NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig5
  • Install the canopy according to the mounting configuration (see figure 6).
  • Feed the unit wires the through canopy hole and make the proper connections (See step 4 and Fig.6).NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig6 NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig8

Make the proper connections (see figure 6):

  • For 120VAC, connect the black wire (120VAC) and white wire (neutral) to the building utility.
  • For 347VAC, connect the red wire (347VAC) and white wire (neutral) to the building utility.
  • Feed wires back into the junction box.

CAUTION!

Risk of electrical shock. Cap unused wires. In all cases, use suitable wire nuts rated for the applied voltage to connect to wires.

For universal AC/DC models: connect wires for external DC supply (see figure 6)NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig9

  • Wire the Yellow lead to the positive(+)
  • Wire the Purple to the Negative(-)

IMPORTANT! Electrical connections for AC and DC wires must be isolated from each other.NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig10

Insert canopy into the housing at 20-degree angle and twist. Quick snap is now locked firmly.
Caution: Trying to remove the canopy after it is locked into place may cause damage.

PACKAGE

Carton (Inch) Qty / Carton Net Weight / Carton Gross Weight / Carton
14.37×9.76×6.14 2PC 5.07LBS 6.17LBS

Application Picture

NOTHING-BUT-LEDS 1550392-LED-Running-Man-Safety-Exit-Sign-fig11

Warranty

Five years warranty for the electrical parts and housing; Three years warranty for battery

Documents / Resources

NOTHING BUT LEDS 1550392 LED Running Man Safety Exit Sign [pdf] Instructions
1550392, LED Running Man Safety Exit Sign, Man Safety Exit Sign, LED Running Exit Sign, Exit Sign, Sign

References

Leave a comment

Your email address will not be published. Required fields are marked *