LED Running Man Safety Exit Sign | 3.5W | 6000-7000K | Green | 120-347 – Nothing But LEDs

PDF preview unavailable. Download the PDF instead.

LED Running Man Safety Exit Sign ?v=1663617536
RUNNING MAN EXIT SIGN

LED EMERGENCY LIGHTS

UL R D

Product Features
· SKU # 1550392 · Output power: 3.5W · CCT: 6000K-7000K · Injection-molded thermoplastic ABS housing · Charging Time: 24H · Discharging Time: 90 MIN · Input Volt: 120/347V/60Hz

· Battery: 3.6V 600mAh Ni-Cd Battery · IP Rating: IP20 · LED: 14 LEDS · Certifications: UL Listed · Warranty: (5 years warranty for the electrical parts and housing; 3 years warranty for battery)"

1

LED EMERGENCY LIGHTS

RUNNING MAN EXIT SIGN

SKU Number 1550392

Specificaons

Parameter
General Performance

Descripon
Model Mode of operation Supply Voltage Power Consumption Output Voltage Output Power Colour Temperature Battery Max Charge Current (mA) Max Discharge Current (mA) Charging Time Discharge Time LED Net Weight Gross Weight IP Rating Safety Classification Certification Picture Warranty

Value
JRMEEW Maintained 120/347V/60Hz 4.5W 4.5VDC 3.5W 6000K -7000K 3.6V 600mAh Ni-Cd Battery AC:85mA/DC:95mA 185mA 24H 90Min 14 LEDS 2.58LBS 2.64LBS IP20
UL Listed
Five years warranty for the electrical parts and housing; Three years warranty for baery.

2

LED EMERGENCY LIGHTS
9.05"

RUNNING MAN EXIT SIGN
Dimensions
13.58 "
1.97 "
3

LED EMERGENCY LIGHTS

RUNNING MAN EXIT SIGN
Installation
LED Pictogram Sign
WARNING: Risk of Shock. Disconnect Power before Installation.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. All servicing should be performed by qualified service personnel. 2. Disconnect power at fuse or circuit breaker before installing or servicing. 3. All electrical connections must be in accordance with local codes,
ordinances and the National Electric code. 4. Do not use outdoors. 5. Do not let power supply cords touch hot surfaces. 6. Do not mount near gas or electric heaters. 7. Equipment should be mounted in locations and at heights where it will not
readily be subjected to tampering by unauthorized personnel. 8. The use of accessory equipment not recommended by the manufacturer
may cause an unsafe condition. 9. Do not use this equipment for other than intended use. 10.Use caution when handling batteries. Battery acid can cause burns to the
skin and eyes. If acid is spilled on the skin or eyes, flush acid with fresh water and contact a physician immediately. Avoid possible shorting. 11. Allow battery to charge for 24 hours before first use.
SAVE THESE INSTRUCTIONS
Installation Instructions
1. Turn off AC power. 2. Using a flat head screwdriver, insert the blade into the two slots and pry
off the front cover (see figure 4). 3. Follow the proper mounting procedure below.
Wall mount
a. Remove the back plate from the packaging. b. Knock out the proper hole pattern on the back plate, including the
center hole, to mount to a standard junction box by supporting the area around the knock outs with two blocks of wood. c. Remove the rear cover and diffuser. d. Install the back plate on to the unit. e. Feed the AC supply leads out through the center hole and make the proper connections (See step 4 and Fig.6).
Ceiling or End Mount
a. Attach crossbar to junction box, set the longer blade of the crossbar to touch the junction box.
4

LED EMERGENCY LIGHTS

RUNNING MAN EXIT SIGN

Installation
b. Remove the mounting hole cover from the top or side

d. Feed the unit wires the through canopy hole and make the proper connections (See step 4 and Fig.6).
a. For 120VAC, connect the black wire (120VAC) and white wire (neutral) to the building utility.
b. For 347VAC, connect the red wire (347VAC) and white wire (neutral) to the building utility.
c. Feed wires back into the junction box.

Risk of electrical shock. Cap unused wires. CAUTION! In all cases, use suitable wire nuts rated for
the applicable voltage to connect to wires.
5. For universal AC/DC models: connect wires for external
a. Wire the Yellow lead to the positive(+) b. Wire the Purple to the Negative(-)

IMPORTANT!

Electrical connections for AC and wires must be isolated from each

DC other.

PACKAGE
Carton (Inch)
14.37x9.76x6.14
5

Qty / Carton
2PC

Net Weight / Carton
5.07LBS

Gross Weight / Carton
6.17LBS

LED EMERGENCY LIGHTS

RUNNING MAN EXIT SIGN
Application Picture
Warranty
Five years warranty for the electrical parts and housing; Three years warranty for baery
6


Adobe PDF library 16.03 Adobe Illustrator(R) 24.0