NATIONAL INSTRUMENTS PXIe-7902 Ethernet Test Solution
COMPREHENSIVE SERVICES
We offer competitive repair and calibration services, as well as easily accessible documentation and free downloadable resources.
SELL YOUR SURPLUS
We buy new, used decommissioned, and surplus parts from every Ni series.
We work out the best solution to suit your individual needs.
- Sell For Cash
- Get Credit
- Receive a Trade-In Deal
Bridging the gap between manufacturer and you legacy test system,.
OBSOLETE NI HARDWARE IN STOCK $ READY TO SHIP
We stock New, New Surplus, Refurbished, and Reconditioned NI Hardware.
Manufacturer
National Instruments
Board Assembly Part Numbers
(Refer to Procedure 1 for identification procedure):
Part Number and Revision | Description |
194710A-04 or later | USB-6210 |
194710A-03 or later | USB-6211 |
196203A-03L or later | USB-6211 OEM |
197493A-03L or later | USB-6212 |
198402A-03L or later | USB-6212 MASS TERMINATION |
190630A-01L or later | USB-6212 BNC |
197504A-03L or later | USB-6212 OEM |
194710A-02 or later | USB-6215 |
197493A-01L or later | USB-6216 |
198402A-01L or later | USB-6216 MASS TERMINATION |
190631A-01L or later | USB-6216 BNC |
197504A-01L or later | USB-6216 OEM |
194710A-01 or later | USB-6218 |
190632A-01L or later | USB-6218 BNC |
196203A-01L or later | USB-6218 OEM |
Volatile Memory
Target Data | Type | Size | Battery Backup | User1 Accessible | System Accessible | Sanitization Procedure |
Glue logic | FPGA 1 | Altera EP1C3 |
No | No | Yes | Cycle Power |
Glue logic | FPGA 2 | Xilinx XC3S500E |
No | No | Yes | Cycle Power |
Program Code | SRAM | 128 KB | No | No | Yes | Cycle Power |
Non-Volatile Memory (incl. Media Storage)
Target Data | Type | Size | Battery Backup | User Accessible | System Accessible | Sanitization Procedure |
Device configuration
|
EEPROM | 2 KB | No | No Yes No |
Yes Yes Yes |
None Procedure 2 None |
1 Refer to Terms and Definitions section for clarification of User and System Accessible
2 Calibration constants that are stored on the device include information for the device’s full operating range. Any implications resulting from partial self-calibration can be eliminated by running the full self-calibration procedure.
Procedures
Procedure 1 –Board Assembly Part Number Identification:
To determine the Board Assembly Part Number and Revision, refer to the “P/N” label applied to the surface of your product as shown below. The Assembly Part Number should be formatted as “P/N: ######a-vvL” where “a” is the letter revision of the Board Assembly (eg. A, B, C…) and the “vv” is the type identifier. If the product is RoHS compliant, “L” can be found at the end of the part number.
USB-6210/6211/6212/6215/6216/6218/6212 MASS TERMINATION/6216 MASS TERMINATION – Label can be found on the bottom of the enclosure.
USB-6211 OEM/6218 OEM – Primary Side
USB-6212 OEM/6216 OEM – Secondary Side
USB-6212 BNC/6216 BNC/6218 BNC – Label can be found on the bottom of the enclosure.
Procedure 2 – Device Configuration EEPROM (Calibration Metadata):
The user-accessible areas of the Device Configuration EEPROM are exposed through a calibration Applications Programming Interface (API) in LabVIEW. To clear the Calibration Metadata area, complete the following steps:
- To clear the calibration password, use the DAQmx Change External Calibration Password.vi to overwrite the current password of the device you wish to clear.
- The user-accessible area of the Device Configuration EEPROM can be cleared using the NI DAQmx API.
For instructions on how to clear these areas, go to www.ni.com/info and enter info code DAQmxLOV.
Terms and Definitions
Cycle Power:
The process of completely removing power from the device and its components and allowing for adequate discharge. This process includes a complete shutdown of the PC and/or chassis containing the device; a reboot is not sufficient for the completion of this process.
Volatile Memory:
Requires power to maintain the stored information. When power is removed from this memory, its contents are lost.
This type of memory typically contains application specific data such as capture waveforms.
Non-Volatile Memory:
Power is not required to maintain the stored information. Device retains its contents when power is removed.
This type of memory typically contains information necessary to boot, configure, or calibrate the product or may include device power up states.
User Accessible:
The component is read and/or write addressable such that a user can store arbitrary information to the component from the host using a publicly distributed NI tool, such as a Driver API, the System Configuration API, or MAX.
System Accessible:
The component is read and/or write addressable from the host without the need to physically alter the product.
Clearing:
Per NIST Special Publication 800-88 Revision 1, “clearing” is a logical technique to sanitize data in all User Accessible storage locations for protection against simple non-invasive data recovery techniques using the same interface available to the user; typically applied through the standard read and write commands to the storage device.
Sanitization:
Per NIST Special Publication 800-88 Revision 1, “sanitization” is a process to render access to “Target Data” on the media infeasible for a given level of effort. In this document, clearing is the degree of sanitization described.
CUSTOMER SERVICE
Notice: This document is subject to change without notice.
For the most recent version.
1-00-915-6216
www.apexwaves.com
sales@apexwaves.com
All trademarks, brands, and brand names are the property of their respective owners.
Contact: 866-275-6964
visit ni.com/manuals | support@ni.com
Documents / Resources
![]() |
NATIONAL INSTRUMENTS USB-6210 Multifunction Device [pdf] Instruction Manual USB-6210, USB-6210 Multifunction Device, Multifunction Device, Device |