namron Zigbee Termostat 16A
namron Zigbee Termostat 16A

Symbol overview

Symbol overview

  1. Zigbee Networking icon
  2. Children Lock
  3. Frost Protection
  4. Manual Mode
  5. Program Mode
  6. Period Program
  7. Temperature/Time
  8. Internal room temperature
  9. External room temperature
  10. Floor Temperature
  11. Regulator mode
  12. Heating mode
  13. Cooling mode
  14. Week Days
  15. Open Window Detected
  16. ECO mode
  17. Percentage
  18. Heating/cooling dynamic ICONS
  19. Targeted temperature
  20. ON/OFF Button
  21. Button “M“
  22. Button “down“
  23. Button “up

Installation

The thermostat is applied to full load in areas with the altitude of less than 2500m above sea level. Power rating of external load should be less than or equal to 80% rated power of the thermostat in areas with altitude of 2500m to 4200m.

WARNING

a. Installation must be carried by a qualified electrician.
b. Before installation, please check whether it conforms to local electric standards.
C. Power supply must be turn off when install and clean the thermostat.
Wipe the surface dust or dirt with soft cloth or tissue, do not use the detergent or other corrosive chemical solution.
Please match with the standard wall box to ensure the installation.
Do not connect the L&N, LO&NO reversely.
Please place and protect the cover properly when it’s in installation to avoid the damage.
When connected to AC230V, the surface cover must be installed. Thermostat is not the SELV product, all the voltage part should be regarded as 230V.

Wiring Diagram

Wiring Diagram
Wiring Diagram

Mounting

Mounting

Technical Data

Input 230VAC+/-10%, 50/60Hz
Max. Pre- fuse 16A
Built-in Switch 1 Pole, 16A
Relay contact Max 16A 250VAC
Output relay 16A, SPST-NO
Floor sensor type / External room sensor The thermostat can be configured as any of the following floor sensor: 3m, NTC, R25=10KQ±1%@25C, B25/50=3950K±1 %(default)
3m,  NTC,  R25=12KQ±2%@25°C, B25/85=3740K±2%(support)
3m,  NTC,  R25=15KQ±2%@25°C, B25/85=3740K±2%(support)
3m,  NTC,  R25=22KQ±2%@25°C, B25/85=3740K±2%(support)
3m,  NTC,  R25=33KQ±2%@25°C, B25/85=4090K±1.5%(support)
3m,  NTC,  R25=47KQ±2%@25°C, B25/85=4090K±1.5%(support)
Build-In sensor NTC, R25=10KQ±1%@25°C, B25/50=3950K±1%
Network function: Standard ZigBee 3.0 protocol.
Wiring Requirements Current≤13A-1.5mm2, solid core wire, HO7V-R wire Current>13A to 16A-2.5mm2, solid core wire, H07V-R wire
Control object Floor Heating
Method of mounting Wall mounted
Control function The thermostat has a build-in sensor and supplied with an floor sensor. Also the thermostat can be connected with an external room sensor. The thermostat can be set for the following functions:
  • Room temperature control Floor temperature control
  • External room temperature control
  • Floor sensor as an external limit sensor for internal room
  • temperature control Floor sensor as an external limit sensor for
  • external room temperature control

Maximum and minimum limitation temperatures can be set

Control mode ①Manual Mode ②Weekly Program mode ③Regulator
Frost Protection Default 5°C to start frost protection,5~10°C controllable. Can be switched on/off manually
Ambient temperature 10°C/+60°C
External limitation 5~60°C (Default 27°C)
Switch deviation 0.5~10°C adjustable (±1°C)
Protection level IP20
Material of casing PC Fire-rated

Normal operation guidance

  1. Short press the Icon ON/OFF key to ON/OFF the backlight on the thermostat display. When it shows , means that backlight is ON, shows , means OFF.
  2. Long press the Icon ON/OFF button 3s to ON/OFF the Thermostat
  3. Under manual control or programmed control mode, short press button “M”- to have mode change.
  4. During the heating(not in regulator P mode), long press” M”2s to switch Digit icon to Digit icon mode.
  5. During the normal mode(Not P mode), short press ”▲”or” ▼”to adjust the current temperature.
  6. During the Programmed mode, short press”▲” or ”▼”to adjust the contemporary time setting temperature which enter the temporary control mode.
  7. In regulator P mode, short press“▲” or“▼ !”to adjust the heating percentage of the current mode, short press “M” to confirm the setting.
  8. Under main screen at any mode press hold the “M” and“ ▲ ”3s at same time to enter the date/time setting. .
  9. Under main screen at any mode press hold the “M” and“▼” 3s at same time to open/close child lock.

Advanced setting;

Long press button “M” for 5seconds at any control mode

Code Shown Meaning of code Short press“▲” or“▼” to select, long press “M“ for 1 second to confirm, short press “M“ to exit
1 Air Temperature calibration Check the Air temperature and calibration:
-10~10°C (factory setting 0°C )
 

2

Floor Temperature calibration Check the floor temperature and calibration:
-10~10°C (factory setting 0°C )
3 External room temperature calibration Measure and correct the temperature of the external room:
-10~10°C (factory0°C)
4  

 

Sensor mode

A:Built-in sensor
F  :Floor sensor (factory default)
AF :Internal temperature control, floor temperature limit
A2 :External room sensor
A2F :External room temperature control, floor temperature limit
P :Controller heating percentage
5  

 

Sensor types

  10K: NTC_ 10K factory default
12K: NTC_ 12K
15K: NTC_ 15K
22K: NTC_ 22K
33K: NTC_ 33K
47K: NTC 47K
 

6

display backlight brightness in working status 10~ 100%, 10% incensement, factory reset 100%
 

7

display backlight brightness in standby status 10~ 100%, 10% incensement, factory reset 10%
8 Floor Limited temp. 5 – 60°C, factory setting 27°C
9 On/Off differential 0.5-10°C, factory setting +1°C
10 Weekly program setting 12345/67: 5/2 (Flashing alternately)
123456/7: 6/1(Flashing alternately)
1234567: 7/0 (Flashing)No rest
1234567 AlI show up: All rest
11 Frost Protection Off: Frost protection off(default) When on: 5-10°C
 

12

 

Regulator

Off: Turn regulator off 1-30min settable heating   schedule time.
In total have 30 schedules can be set. (default 30min)
13 Self- Adjust Off: Self adaption function Off
On: Self adaption function on (factory default OFF)
14 Lower limit of air sensor temperature 0.5~38°C (factory setting 5°C)
15 Upper limit of Air sensor temperature 2.5~40°C (factory setting 40°C)
16 Lower limit of Floor sensor temperature 0.5~38°C (factory setting 5°C)
17 Upper limit of Floor sensor temperature 2.5~40°C (factory setting 40°C)
18 Lower limit of external room sensor temperature 0.5~38°C (factory setting 5°C)
19 Upper limit of external room sensor temperature 2.5~40°C (factory setting 40°C)
20 Activate Zigbee in-network/off-network mode Zigbee Inclusion: Make sure the device does not belong to any network. Enter advance setting find option and long press button M for 2s ready for inclusion, meanwhile set your Zigbee controller in inclusion mode.
When the display shows …a. the device is in inclusion status. The display will shows  as well as Zigbee logo is on means the inclusion is successful.  will be showed when inclusion is failed.
*For Homey inclusion please double press button “M” then it can be included. Zigbee exclusion: Enter advance setting, find option and long press button M for 2s ready for exclusion, meanwhile set your Zigbee controller in exclusion mode. When the display shows …, means the device is in exclusion status. The display will shows and the Zigbee logo is off meanxs the exclusion is successful. will be showed when exclusion is failed.
*For Homey exclusion please double press button “M” then it can be Excluded.
21 Operating mode Working mode COOL: Cooling mode
HEAT: Heating mode (factory default)
22 Date display mode DDMM: Day day/month (factory setting) MMDD: Month month/day day
23 Open window function Disable the open window function
Enable the open window function (Factory Default)
24 Factory Reset In the option, long press “M” 5s to go back to factory reset.
25 Exit advanced settings Short press “M” to confirm and exit