namron Zigbee Termostat 16A
Symbol overview
- Zigbee Networking icon
- Children Lock
- Frost Protection
- Manual Mode
- Program Mode
- Period Program
- Temperature/Time
- Internal room temperature
- External room temperature
- Floor Temperature
- Regulator mode
- Heating mode
- Cooling mode
- Week Days
- Open Window Detected
- ECO mode
- Percentage
- Heating/cooling dynamic ICONS
- Targeted temperature
- ON/OFF Button
- Button “M“
- Button “down“
- Button “up
Installation
The thermostat is applied to full load in areas with the altitude of less than 2500m above sea level. Power rating of external load should be less than or equal to 80% rated power of the thermostat in areas with altitude of 2500m to 4200m.
WARNING
a. Installation must be carried by a qualified electrician.
b. Before installation, please check whether it conforms to local electric standards.
C. Power supply must be turn off when install and clean the thermostat.
Wipe the surface dust or dirt with soft cloth or tissue, do not use the detergent or other corrosive chemical solution.
Please match with the standard wall box to ensure the installation.
Do not connect the L&N, LO&NO reversely.
Please place and protect the cover properly when it’s in installation to avoid the damage.
When connected to AC230V, the surface cover must be installed. Thermostat is not the SELV product, all the voltage part should be regarded as 230V.
Wiring Diagram
Mounting
Technical Data
Input | 230VAC+/-10%, 50/60Hz |
Max. Pre- fuse | 16A |
Built-in Switch | 1 Pole, 16A |
Relay contact | Max 16A 250VAC |
Output relay | 16A, SPST-NO |
Floor sensor type / External room sensor | The thermostat can be configured as any of the following floor sensor: 3m, NTC, R25=10KQ±1%@25C, B25/50=3950K±1 %(default) 3m, NTC, R25=12KQ±2%@25°C, B25/85=3740K±2%(support) 3m, NTC, R25=15KQ±2%@25°C, B25/85=3740K±2%(support) 3m, NTC, R25=22KQ±2%@25°C, B25/85=3740K±2%(support) 3m, NTC, R25=33KQ±2%@25°C, B25/85=4090K±1.5%(support) 3m, NTC, R25=47KQ±2%@25°C, B25/85=4090K±1.5%(support) |
Build-In sensor | NTC, R25=10KQ±1%@25°C, B25/50=3950K±1% |
Network function: | Standard ZigBee 3.0 protocol. |
Wiring Requirements | Current≤13A-1.5mm2, solid core wire, HO7V-R wire Current>13A to 16A-2.5mm2, solid core wire, H07V-R wire |
Control object | Floor Heating |
Method of mounting | Wall mounted |
Control function | The thermostat has a build-in sensor and supplied with an floor sensor. Also the thermostat can be connected with an external room sensor. The thermostat can be set for the following functions:
Maximum and minimum limitation temperatures can be set |
Control mode | ①Manual Mode ②Weekly Program mode ③Regulator |
Frost Protection | Default 5°C to start frost protection,5~10°C controllable. Can be switched on/off manually |
Ambient temperature | 10°C/+60°C |
External limitation | 5~60°C (Default 27°C) |
Switch deviation | 0.5~10°C adjustable (±1°C) |
Protection level | IP20 |
Material of casing | PC Fire-rated |
Normal operation guidance
- Short press the
ON/OFF key to ON/OFF the backlight on the thermostat display. When it shows , means that backlight is ON, shows , means OFF.
- Long press the
ON/OFF button 3s to ON/OFF the Thermostat
- Under manual control or programmed control mode, short press button “M”- to have mode change.
- During the heating(not in regulator P mode), long press” M”2s to switch
to
mode.
- During the normal mode(Not P mode), short press ”▲”or” ▼”to adjust the current temperature.
- During the Programmed mode, short press”▲” or ”▼”to adjust the contemporary time setting temperature which enter the temporary control mode.
- In regulator P mode, short press“▲” or“▼ !”to adjust the heating percentage of the current mode, short press “M” to confirm the setting.
- Under main screen at any mode press hold the “M” and“ ▲ ”3s at same time to enter the date/time setting. .
- Under main screen at any mode press hold the “M” and“▼” 3s at same time to open/close child lock.
Advanced setting;
Long press button “M” for 5seconds at any control mode
Code Shown | Meaning of code | Short press“▲” or“▼” to select, long press “M“ for 1 second to confirm, short press “M“ to exit | |
1 | ![]() |
Air Temperature calibration | Check the Air temperature and calibration: -10~10°C (factory setting 0°C ) |
2 |
![]() |
Floor Temperature calibration | Check the floor temperature and calibration: -10~10°C (factory setting 0°C ) |
3 | ![]() |
External room temperature calibration | Measure and correct the temperature of the external room: -10~10°C (factory0°C) |
4 | ![]() |
Sensor mode |
![]() ![]() ![]() ![]() ![]() ![]() |
5 | ![]() |
Sensor types |
![]() ![]() ![]() ![]() ![]() ![]() |
6 |
![]() |
display backlight brightness in working status | 10~ 100%, 10% incensement, factory reset 100% |
7 |
![]() |
display backlight brightness in standby status | 10~ 100%, 10% incensement, factory reset 10% |
8 | ![]() |
Floor Limited temp. | 5 – 60°C, factory setting 27°C |
9 | ![]() |
On/Off differential | 0.5-10°C, factory setting +1°C |
10 | ![]() |
Weekly program setting | ![]() ![]() ![]() ![]() |
11 | ![]() |
Frost Protection | ![]() |
12 |
![]() |
Regulator |
![]() In total have 30 schedules can be set. (default 30min) |
13 | ![]() |
Self- Adjust | Off: Self adaption function Off On: Self adaption function on (factory default OFF) |
14 | ![]() |
Lower limit of air sensor temperature | 0.5~38°C (factory setting 5°C) |
15 | ![]() |
Upper limit of Air sensor temperature | 2.5~40°C (factory setting 40°C) |
16 | ![]() |
Lower limit of Floor sensor temperature | 0.5~38°C (factory setting 5°C) |
17 | ![]() |
Upper limit of Floor sensor temperature | 2.5~40°C (factory setting 40°C) |
18 | ![]() |
Lower limit of external room sensor temperature | 0.5~38°C (factory setting 5°C) |
19 | ![]() |
Upper limit of external room sensor temperature | 2.5~40°C (factory setting 40°C) |
20 | ![]() |
Activate Zigbee in-network/off-network mode | Zigbee Inclusion: Make sure the device does not belong to any network. Enter advance setting find option and long press button M for 2s ready for inclusion, meanwhile set your Zigbee controller in inclusion mode. When the display shows …a. the device is in inclusion status. The display will shows ![]() ![]() ![]() *For Homey inclusion please double press button “M” then it can be included. Zigbee exclusion: Enter advance setting, find option and long press button M for 2s ready for exclusion, meanwhile set your Zigbee controller in exclusion mode. When the display shows …, means the device is in exclusion status. The display will shows ![]() ![]() ![]() *For Homey exclusion please double press button “M” then it can be Excluded. |
21 | ![]() |
Operating mode Working mode | ![]() ![]() |
22 | ![]() |
Date display mode | DDMM: Day day/month (factory setting) MMDD: Month month/day day |
23 | ![]() |
Open window function | ![]() ![]() |
24 | ![]() |
Factory Reset | In the ![]() |
25 | ![]() |
Exit advanced settings | Short press “M” to confirm and exit |
Documents / Resources
![]() |
namron Zigbee Termostat 16A [pdf] Instruction Manual Zigbee Termostat 16A, Zigbee, Termostat 16A, 16A |