MP751059 Dual Channel Arbitrary Waveform Generator

Dual-Channel Arbitrary Waveform Generator Quick Start Guide MP751059 & MP751060

Table of Contents
1.General Safety Requirement……………………………………………………. 1 2.Safety Terms and Symbols………………………………………………………. 2 3. General Inspection ………………………………………………………………….. 3 4. Quick Start………………………………………………………………………………. 4
Front panel overview…………………………………………………………………………………………………….4 Rear Panel Overview ……………………………………………………………………………………………………. 5 Power on……………………………………………………………………………………………………………………..6 User Interface ……………………………………………………………………………………………………………… 6 Set the channel…………………………………………………………………………………………………………….7 Set basic waveform ……………………………………………………………………………………………………… 8 Output the built-in waveform (including DC)……………………………………………………………………9 Generate the Modulated Waveform……………………………………………………………………………….9 Generate Sweep ………………………………………………………………………………………………………….. 9 Generate Burst …………………………………………………………………………………………………………..10 Store ………………………………………………………………………………………………………………………… 10 Communication with PC………………………………………………………………………………………………10
Reading waveform…………………………………………………………………………………………….11 Write and Recall waveform ……………………………………………………………………………….11 Utility Setting …………………………………………………………………………………………………………….. 12
5.Appendix……………………………………………………………………………….. 14
Appendix AAccessories…………………………………………………………………………………………….14 Appendix BGeneral Care and Cleaning……………………………………………………………………….14
i

1. General Safety Requirement
1. General Safety Requirement
Before first use, please read the following safety precautions to avoid any possible personal injury and prevent this product or any other products connected to it from damage. Use only the PSU supplied or one of identical specification. Check to ensure the PSU used matches your local mains supply before connecting. Do not operate without covers. Do not operate the instrument with covers or panels removed. If you suspect damage has occurred to the instrument. Have it inspected by qualified service personnel before further use. Use your instrument in a well-ventilated area. Inadequate ventilation may cause increase of temperature or damage to the device. Keep well ventilated and inspect the intake for dust and dirt regularly. Do not operate in damp conditions. To avoid short circuiting to the interior of the device or possible electric shock, do not operate in a humid environment. Do not operate in an explosive atmosphere. Keep product surfaces clean and dry. No user serviceable parts inside. Do not disassemble, all servicing must be done by an approved technician.
1

2.Safety Terms and Symbols
2. Safety Terms and Symbols
Terms in this Manual. The following terms may appear in this manual: Warning: Warning indicates the conditions or practices that could result in personal injury or loss of life. Caution: Caution indicates the conditions or practices that could result in damage to this product or other connected devices.
Safety Symbols
Symbols on the product. The following symbol may appear on the product depending on the model:
2

3.General Inspection
3. General Inspection
After you get a new instrument, it is recommended that you should make checks as follows: 1. Check whether there is any damage caused by transportation. If it is found that the outer carton or internal packaging has suffered serious damage, do not dispose of it until the complete device and its accessories have been thoroughly tested. 2. Check the Accessories Check that all the accessories are intact. If there is any accessory missing or damaged, please get in touch with the Multicomp-pro distributor. 3. Check the Complete Instrument If it is found that there is damage to the appearance of the instrument, or the instrument does not work normally, or fails in the performance test, please get in touch with the Multicomp-pro distributor. If there is damage to the instrument caused by the transportation, please keep all the packaging. Please get in touch with the Multicomp-pro distributor to arrange repair or replacement as required.
3

4. Quick Start

4.Quick Start

Front Panel Overview

Figure 4- 1 Front Panel Overview

1 LCD

Display the user interface

2 Menu selection keys
3 Mode keys

Includes 5 keys to activate the corresponding menu
Modeoutput the modulated waveform BothDisplay the editable parameters of both channels

4 Knob

Change the currently selected value, also used to select the arbitrary waveform types and arb data file name. When in the sweep manual mode, press this knob to trigger manually

5 Direction key Move the cursor of the selected parameter

6 Utility

Set the utility function

7 Power button Turn on/off the waveform generator.

8 Number keypad

Input the parameter

4

4.Quick Start

9 On/Off button Turns the output of the CH2 channel on or off. When the output is turned on, the button backlight lights up

10 Out 2

Output CH2 signal

11 CH1/CH2

Switch the channel displayed on the screen between CH1 and CH2

12 Out 1

Output CH1 signal

13 On/Off button Turns the output of the CH1 channel on or off. When the output is turned on, the backlight of the button lights up

14 Waveform Selection buttons

Includes: Sine , Square , Ramp , Pulse , Noise , Arb Wave

Rear Panel Overview

Figure 4- 2 Rear Panel Overview

1 Air vents

2 Power input connector DC power input connector
3 Rubber feet

4 USB Device Used to connect a USB type B controller. Can be

interface

connected to a PC, the signal generator can be controlled

by the host computer software.

5

4.Quick Start
Power on
(1) Connect the instrument to the AC power using the DC power adapter included with the product.
(2) Press the power button on the front panel. The back light of the power channel switch will light up, and the buzzer will sound.
User Interface

Figure 4- 3 User Interface

1 Display channel name 2 Display channel switch status 3 Display load 4 Current waveform mode
Indicator to show when connected to the USB Host via the 5 USB DEVICE interface

6 Buzzer

7 Menu title

8 Current waveform or mode setting menu

9 Start phase

10 Offset / low level, depending on the right highlighted menu item

11

Amplitude / high level, depending on the right highlighted menu item

6

4.Quick Start

12

Frequency/Period, depending on the highlighted menu item on the right

13 Displays the current waveform

Setting the channel
Select the channel for configuration
Before configuring waveform parameters, you must first select the channel you want to configure. Press CH1 /CH2 to switch to the desired channel and the user interface. To Display / Edit Both Channels
Press Both button to display the parameters of both channels.
To switch channel: Press CH1/2 to switch the editable channel.
To select waveform: Press Waveform selection buttons to select the waveform for the current channel.
To select parameter: Press Menu selection keys to choose the Parameter 1 to Parameter 4Corresponding keys 2-4;Press it again to switch the current parameter such as Frequency/Period.
To edit parameter: Turn the knob to change the value of cursor position. Press / direction key to move the cursor. (The number keys cannot be used to
input.)

Turn on/off the channel output Press CH1 On/Off or CH2 On/Off on the front panel to turn on/off the corresponding channel output. The backlight of the button lights up when it is set to output.
7

4.Quick Start

Setting a basic waveform

To set and output the Sine, Square, Ramp, Pulse, Noise or Arbitrary

waveform, press the waveform selection button on the front panel of the

instrument: sine

, square

, ramp

, pulse

, noise

,

arbitrary

to enter the corresponding waveform setting interface. The

waveform is different and the parameters that can be set are relative.

Example: Press the

key and press the Frequency/Period soft key. The

selected menu item is highlighted in white, and the cursor will display on

corresponding parameter item in the user interface. Press the

Frequency/Period softkey to switch the frequency/period.

There are two ways to change the selected parameter value:
Turn the Knob to increase or decrease the value at the cursor. Press the direction keys to move the cursor left or right.
Press a number key on the numeric keypad directly, the screen will display the data input box, continue to input the desired value. Press the right menu soft key to select the unit of the parameter. Press the Back softkey to cancel the current entry.

Figure 4- 4Use numeric keypad to set the frequency

Parameters of waveforms

Waveform Sine Square

Menu Items Frequency/Period, Amplitude/High Phase Frequency/Period, Amplitude/High Phase

Level, Level,

Offset/Low Offset/Low

Level, Level,

8

4.Quick Start

Ramp
Pulse Noise Arbitrary

Frequency/Period, Amplitude/High Level, Offset/Low Level, Phase Symmetry
Frequency/Period, Amplitude/ High Level, Offset/Low Level, Phase, Width/Duty, Rise, Fall Amplitude/High Level, Offset/Low Level Frequency/Period, Amplitude/High Level, Offset/Low Level, Phase, Bult-in, Store

Output the built-in waveform (including DC)

(1) Press the

arbitrary wave button, then press the NextPage ,to the

nextpage menu.

(2) Press the Built-in softkey,go to the build-in waveform and select the menu

(3) Press the Common, Medical treatment, Standard softkeys to select the build-in waveform mode

Press the NextPage softkeys, to select the build-in waveformMaths, Trigonometric, Window function.

Press the NextPage softkeys, to select the build-in waveformEngineering, Seg Mod, Fan test.

Note: DC is a type of built-in waveform, located in the “Common” category, named “DC”.

Generate the Modulated Waveform

Supported modulation types include: AM (Amplitude Modulation), FM (Frequency Modulation), PM (Phase Modulation), FSK (Frequency Shift Keying).

Press the Mode function key, to select the modulation type enter the setup menu. To turn off the modulation, press the Mode function button again.

Parameters of modulated waveforms:

Type

Parameters

AM

Shape, AM Frequency, Depth

FM

Shape, FM Frequency, Deviation

PM

Shape, PM Frequency, Phase Deviation

FSK

FSK Rate, Hop Frequency

Generate Sweep

In the frequency sweep mode, the generator “steps” from the start frequency 9

4.Quick Start
to the stop frequency at the sweep rate you specify. Sweep can be generated by Sine, Square, Ramp or Arbitrary waveforms.
When the output signal is Sine, Square, Ramp or Arbitrary waveform, press the front panel Mode key ,then press the Sweep to enter the sweep mode. The parameters allowed to be set are: Sweep Time, Linear/Log, Start Frequency/Center Frequency, Stop Frequency/Frequency Span, Source.
Generate a Burst Waveform
Press the Mode function key, then press the Burst to enter burst mode, to generate versatile waveforms in burst. Burst can last for certain times of waveform cycle (N-Cycle Burst). Bust can apply to Sine, Square, Ramp, Pulse and Arbitrary waveforms. The parameters allowed to be set are: Burst Period, Cycles/Infinite and Trigger source.
Storing a Waveform
Supports communication with a computer via the USB port. Using the Waveform Editor software installed on the computer, the signal generator can be operated on the computer to control the output and to store outputs from the signal generator. The instrument settings can be saved as files in internal memory. Up to 16 instrument settings can be saved in the instrument internal memory.
Note: Please go to the Multicomp-pro product page to download the Waveform Editor communication software and install it.
Communication with PC
(1) Set the USB device protocol type of the signal generator: Press Utility System USBDev, switch to PC.
(2) Connection: Connect the USB Device interface on the rear panel of the signal generator to the USB interface of the computer with a USB cable.
(3) Install the driver: Run Waveform Editor software on the computer. Follow the instructions to install the driver. The path of the driver is the USBDRV folder in the directory where the Waveform Editor communication software is located, such as “C:Program Files (x86)DS_WaveWaveform EditorUSBDRV”.
(4) Host computer communication port setting: Open the Waveform Editor software, click “Communications” in the menu bar, select “Ports-Settings”, in the setting dialog box, select the communication port as “USB”.
10

4.Quick Start
After the connection is successful, the connection status prompt in the lower right corner of the software interface turns green.

Reading the Waveform
(1) Run “Waveform Editor.exe”

(2) Enter the “Waveform Editor” interface (3) Press the required waveform on the instrument

(4) Click on Read Waveform read and displayed.

on the waveform editor and the waveform is

Write and recall the waveform
Use the Line Draw, Hand Draw and Point Edit mode in the Waveform Editor to edit the required waveform, and save and display it on the instrument. (1) Under Waveform Editor software interface, Click “Write waveform lcon “. (2) After the writing is successful, the “File transfer completed” prompt box will
be displayed in the waveform editor. Click “OK”.
11

4.Quick Start

(3) On the instrument, the screen shows “Wave has been updated to USERX (X is 0-15)”.

(4) Press the

Arb Wave button ,then press the NextPage button to enter

the NextPage menu.

(5) Press the Store soft key to enter the file system, and then press the Enter soft key to enter the file system. Select the file name “USERX” that has just written the waveform.

(6) Press the Call out soft key, the screen displays “File read successfully”,

then press the

arbitrary wave key, the written waveform can be

viewed on the instrument.

Note: The file size is displayed on the right of the file. If 0B is displayed, the file is empty.

Utility Setting

Press the front panel Utility function key to enter the system options menu. The user can set the display parameters of the signal generator, CH1/2 parameters, interface parameters and system parameters. Press Utility again to exit the system options menu.
Utility system menu

Menu

Description

Display Setting

Backlight

Set the screen brightness

Switch On/Off the screen saverWhen set to On the time Screen saver
before actuating can be adjusted from 0-9999

Separator

Set the separator for the screen display data

CH1/2 Setting

CH1 Load CH2 Load Align Phase

Used to match the display voltage with the desired load. The range is from 1 to 10 k
Adjust the phase alignment of the two channels

System Setting

Language

Select the required interface language

Beeper

Turn the sounder ON or Off

USB Device Select the communication protocol for the USB Device interface

12

4.Quick Start

USB Device
Factory Set Upgrade

PC: This is the internal communication protocol. Select this option when connecting to the Waveform Editor software running on a computer via the USB Device interface. USBTMC: Select this when you need to use the USBTMC communication protocol standard.
Reset to factory settings. The instrument firmware can be updated using a USB storage device through the rear panel USB interface.

13

5. Appendix

5.Appendix

Appendix AAccessories
2 × 5VDC power adapter (UK & EU) 1 × USB power cable 1 × Quick Guide 1 × BNC/Q9 cable 1 × BNC to alligator cable 1 × USB communication cable
Appendix BGeneral Care and Cleaning
General Maintenance Do not store or leave the instrument where the liquid crystal display will be exposed to direct sunlight for long periods of time. Caution: To avoid any damage to the instrument or probe, do not expose to any corrosive liquids or solvents. Cleaning Inspect the instrument and probes regularly. To clean the instrument exterior perform the following steps: 1. Disconnect power before cleaning your instrument. 2. Wipe any dust from the instrument and probe surface with a soft cloth. Do not scratch the transparent LCD protection screen when cleaning the display. 3. Clean the instrument further with a moist soft cloth. Mild detergent may be used on stubborn marks. To avoid damage to the instrument or probe, do not use any corrosive chemical cleaning agent.
Warning: Before powering on again for operation, it should be confirmed that the instrument has been dried completely, avoiding any electrical short circuit or possible electric shock to the user.

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT.
When this product has reached the end of its life it must be treated as Waste Electrical & Electronics Equipment (WEEE). Any WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and recycling of the materials used. Contact your local authority for details of recycling schemes in your area.
Made in China 150 Armley Road, Leeds, LS12 2QQ (UK) Riverside One, Sir John Rogerson Quay, Dublin 2 (EU)
14

Documents / Resources

multicomp PRO MP751059 Dual Channel Arbitrary Waveform Generator [pdf] User Guide
MP751059, MP751060, MP751059 Dual Channel Arbitrary Waveform Generator, MP751059, Dual Channel Arbitrary Waveform Generator, Channel Arbitrary Waveform Generator, Arbitrary Waveform Generator, Waveform Generator

References

Leave a comment

Your email address will not be published. Required fields are marked *