Manwal tal-Istruzzjonijiet tal-Modulu tal-Kontrollur tal-Awtonomija Carnegie Robotics 55001384

55001384 Modulu tal-Kontrollur tal-Awtonomija

Speċifikazzjonijiet

Manifattur: Robotika Carnegie

Numru tal-Mudell: 55001384

Istruzzjonijiet dwar l-Integrazzjoni: KDB 996369 D03 OEM
Manwal v01

Istruzzjonijiet għall-Użu tal-Prodott

1. FCC Rules Compliance

The module integrator must assess worst-case operating
conditions and test the host product for compliance to FCC Part
15.247 and Part 15.407.

2. Kundizzjonijiet ta' Użu Operattiv

The module is standalone. Consult with the module manufacturer
for installation methods if the end product involves multiple
simultaneous transmissions or different operational conditions.

3. RF Exposure Guidelines

Install and operate the equipment at a minimum distance of 20cm
from the body to comply with FCC’s and ISED’s RF Exposure
linji gwida.

4. Antenni

This radio transmitter is FCC approved to operate with specific
antenna types and maximum permissible gain. Use only approved
antennas listed in the manual.

5. Labeling and Compliance

The final end product must be labeled with FCC ID:
2AMDR-55001384 and IC: 24410-55001384 in a visible area.

6. Additional Testing Requirements

Host manufacturers are advised to confirm compliance with FCC
and ISED requirements when the module is installed in the host
sistema.

7. FCC Attenzjoni

Any changes or modifications not approved could void the user’s
awtorità biex tħaddem it-tagħmir.

FAQ

Q: What are the recommended distances for RF exposure
konformità?

A: The equipment should be installed and operated at a minimum
distance of 20cm from the body to comply with FCC’s and ISED’s RF
Linji gwida dwar l-espożizzjoni.

Q: Nista 'nuża antenni mhux elenkati fil-manwal?

A: Antenna types not included in the approved list are strictly
prohibited for use with this device to maintain compliance.

"`

Carnegie Robotics 55001384 Integration Instructions
Deskrizzjoni:
Qualcomm® Robotics RB5 Core Kit consisting of Thundercomm TurboX C865 System on Module with customization around 12GB Ram and external antennas enabled for system integration.
See Qualcomm or Thundercomm hardware manuals for specifications to each product.

Integration instructions for host product manufacturers according to KDB 996369 D03 OEM Manual v01 (ISED recognized)

2.2

Lista tar-regoli FCC applikabbli

CFR 47 FCC PARTI 15 SUBPARTI C&E ġiet investigata. Huwa applikabbli għall-modulari.

Specifically, an assessment of the worst case operating conditions has to be performed by the module integrator and tested on the host product for compliance to FCC part 15.247 and part 15.407.

2.3

Kundizzjonijiet speċifiċi għall-użu operattiv

This module is a stand-alone module. If the end product will involve the Multiple simultaneously

transmitting condition or different operational conditions for a stand-alone modular transmitter in a host,

the host manufacturer has to consult with the module manufacturer for the installation method in the end

sistema.

2.4

Limited module procedures. – Not applicable

2.5

Trace antenna designs. – Not applicable

2.6

Konsiderazzjonijiet ta' espożizzjoni RF

To maintain compliance with FCC’s and ISED’s RF Exposure guidelines, this equipment should be

installed and operated at a minimum distance of 20cm from your body.

2.7

Antenni

This radio transmitter FCC ID: 2AMDR-55001384 / IC: 24410-55001384

has been approved by the Federal Communications Commission to operate with the antenna types listed below, with the maximum permissible gain indicated. Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device.

Carnegie Robotics LLC, 4501 Hatfield St. Pittsburgh, PA 15201, USA, Phone 412-200-5539

Identifikazzjoni Interna
Antenna 0**

Antenna Description Wi-Fi Antenna

Tip ta 'antenna
External Antenna 2X MIMO WIFI

Qligħ massimu ta 'l-antenna
2.4G Wi-Fi: 1.2 dBi, 5G Wi-Fi: 2.0dBi

Antenna 1

Wi-Fi Antenna

External Antenna 2X MIMO WIFI

2.4G Wi-Fi: 1.2 dBi, 5G Wi-Fi: 2.0dBi

**Bluetooth has been disabled on device and has not been tested

Antennas Tested: Abracon Part Number AECW0401W2-0600F_DS Taoglas MA210.K.CG.001

2.8

Label and compliance information.

Il-prodott finali finali għandu jkun ittikkettat f'żona viżibbli b'dan li ġej:

Contains FCC ID: 2AMDR-55001384, IC: 24410-55001384

2.9

Informazzjoni dwar il-modi tat-test u r-rekwiżiti addizzjonali tal-ittestjar

Host manufacturers are strongly recommended to confirm compliance with FCC and ISED requirements

for the transmitter when the module is installed in the host.

2.10

Ittestjar addizzjonali, Parti 15 Subparti B u ċaħda ta' responsabbiltà tal-ICES-003

The host manufacturer is responsible for compliance of the host system with module installed with all other

applicable requirements for the system such as FCC Part 15 B and ICES-003.

Attenzjoni FCC:

Carnegie Robotics LLC, 4501 Hatfield St. Pittsburgh, PA 15201, USA, Phone 412-200-5539

Kwalunkwe Tibdil jew modifika mhux approvata espressament mill-parti responsabbli għall-konformità tista' tħassar l-awtorità tal-utent biex iħaddem it-tagħmir.
FCC and ISED Statements This device complies with Part 15 of the FCC Rules and with ICES-003 of the ISED rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR Innovation, Sciences et Développement économique (d’ISDE) Canada applicables aux appareils radio. L’exploitation est autorisée aux deux conditions suivantes:
(1) l-appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage is susceptible d'en compromettre the functionnement.
IMPORTANT NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ICES-003 of the ISED Canada rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
–Orjenta mill-ġdid jew iċċaqlaq l-antenna li tirċievi.
–Iżżid is-separazzjoni bejn it-tagħmir u r-riċevitur.
Carnegie Robotics LLC, 4501 Hatfield St. Pittsburgh, PA 15201, USA, Phone 412-200-5539

–Ikkonnettja t-tagħmir f'bokk fuq ċirkwit differenti minn dak li miegħu huwa mqabbad ir-riċevitur. –Ikkonsulta lin-negozjant jew lil tekniku tar-radju / TV bl-esperjenza għall-għajnuna.
Statements regarding human exposure With respect to radiofrequency radiation exposure Information, it is declared that this equipment complies with FCC and ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated at a minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
Déclarations concernant l’exposition humaine Respectant les informations relatives à l’exposition aux radiations de fréquences radio, on déclare que cet équipement respecte les limites d’exposition aux radiations de l’ISDE aux conditions prévues pour un environnement non contrôlé. Cet équipement doit être installé et fonctionner à une distance minimale de 20 cm entre l’appareil irradiant et votre corps. Cet émetteur ne doit pas être installé ou utilisé en conjonction avec d’autres antennes ou d’autres émetteurs.
Carnegie Robotics LLC, 4501 Hatfield St. Pittsburgh, PA 15201, USA, Phone 412-200-5539