ioLogik E2200 Series Smart Ethernet Remote
Installation Guide
Package Checklist
- 1 ioLogik E2200 series remote I/O product
- Quick installation guide (printed)
- LDP1602 LCD Module (Optional)
Specifications
Ethernet Interface | |
10/100BaseT(X) Ports (R)45 connector) | 1 |
Magnetic Isolation Protection | 1.5 kV (built-in) |
Ethernet Software Features | |
Configuration Options | Web Console (HTTP), Windows Utility |
Industrial Protocols | CGI commands, Modbus TCP Server (Slave), Moxa AOPC (Active Tag), MXIO Library, SNMPv1 Trap, SNMPv1/v2c/v3 |
Management | ioAdmin, BootP, IPv4, SMTP, DHCP Client, HTTP, Web Console, TCP/IP |
MIB | Device Settings MIB |
Time Management | SNTP |
Serial Interface | |
Baudrate | 1200 bps to 115,200 kbps |
Connector | Terminal block |
No. of Ports | 1 |
Parity | None |
Serial Standards | RS-485 |
Stop Bits | 8 |
Serial Signals | |
RS-485-2w | Data+, Data-, GND |
Power Parameters | |
Input Voltage | 12 to 36 VDC |
No. of Power Inputs | 1 |
Power Connector | 1 removable 6-contact terminal block |
Power Consumption | ioLogik E2210 Series: 202 mA @ 24 VDC ioLogik E2212 Series: 136 mA @ 24 VDC ioLogik E2214 Series: 170 mA @ 24 VDC ioLogik E2240 Series: 198 mA @ 24 VDC ioLogik E2242 Series: 178 mA @ 24 VDC ioLogik E2260 Series: 95 mA @ 24 VDC ioLogik E2262 Series: 160 mA @ 24 VDC |
Physical Characteristics | |
Dimensions | 115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in) |
Weight | 250 g (0.55 lb) |
Installation | DIN-rail mounting, wall mounting |
Wiring | I/O cable, 16 to 26 AWG Power cable, 16 to 26 AWG |
Environmental Limits | |
Operating Temperature | Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | S to 950/0 (non-condensing) |
Altitude | 2000 m (Please contact Moxa if you require products guaranteed to function properly at higher altitudes.) |
LED Indicators
LED | Light | Description |
PWR | Off | System power off |
Red | System power on | |
RDY | Off | System not ready |
Green | System ready | |
Red | System error | |
Green, blinking | Click & Go running | |
Green/Red, blinking | System in Safe mode | |
Serial | Off | Serial port not connected |
Red | Serial port connected | |
Blinking | Data sending and receiving | |
Ethernet | Off | Ethernet port not connected |
Amber | 10 Mbps connected | |
Green | 100 Mbps connected | |
Blinking | Data sending and receiving | |
DI | Off | DI status off |
Green | DI status on | |
DO | Off | DO status off |
Red | DO status on | |
DIO | Off | DI or DO status off |
Green | DI mode and status on | |
Amber | DO mode and status on | |
AI | Off | AI channel disabled Transmitter not connected when in 4 to 20 mA mode |
Green | AI channel enabled | |
RTD | Green | RTD status on |
Red | RTD transmitter not connected | |
TC | Green | TC status on |
Red | TC transmitter not connected | |
DO Power | Off | External power off or not connected |
Red | External power on |
I/O Wiring Diagrams
Contact Type | Power Source Requirement |
Dry Contact | A dry Contact does not need to be connected to a power source to function properly.* |
Wet Contact | A wet Contact must be connected to a power source to function properly. |
*Some users connect dry contacts to a power source for added stability.
Depending on your application, you can decide whether or not to connect your dry contacts to power sources.
Mounting
There are two ways to mount the ioLogik E2200 Series: DIN rail or wall mounting.
- Mounting on a DIN rail
Pull out the bottom slider; latch the unit onto the DIN rail, and then push the slider back in. - Mounting on a wall
Pull out both the top and bottom sliders and align the screws accordingly. The heads of the screws should be less than 6.0 mm in diameter, and the shafts should be less than 3.5 mm in diameter, as shown in the figure.
Connecting to the ioLogik E2200
You have two ways to connect to the ioLogik E2200: by admin or by web console.
- Default IP Address: 192.168.127.254
- Subnet Mask: 255.255.255.0
NOTE Be sure to configure the host PC’s IP address to the same subnet as the ioLogik E2200. For example, 192.168.127.253
Restore Factory Defaults
There are three ways to restore the ioLogik to factory default settings.
- Hold the RESET button for 5 seconds.
- Right-click on the specific ioLogik in the admin utility and select Reset to Default.
- Select Load Factory Default from the web console.
NOTE Refer to the user’s manual for detailed configuration and settings information.
How to Download the Software
Step 1: Click on the following link to open the Support & Downloads search tool: http://www.moxa.com/support/support_home.aspx?isSearchShow=1
Step 2: Type the model name in the search box or select a product from the drop-down box and then click Search.
Step 3: Click the Software Packages link to download the latest software for the product.
www.moxa.com/support
P/N: 1802022000011