ആമുഖം
This user manual provides comprehensive instructions for the safe and efficient operation, setup, and maintenance of the JBC JTSE-2QA Digital Hot Air Rework Station. Please read this manual thoroughly before using the device to ensure optimal performance and longevity.
ഉൽപ്പന്നം കഴിഞ്ഞുview

Figure 1: The JBC JTSE-2QA Digital Hot Air Rework Station, featuring the main unit with digital display, the hot air tool, and its dedicated stand. This station is designed for precise and controlled hot air applications in electronics rework.
The JBC JTSE-2QA is a high-performance digital hot air rework station designed for professional electronics repair and assembly. It offers precise temperature control and airflow management, making it ideal for desoldering and soldering surface-mount components (SMD).
സുരക്ഷാ നിർദ്ദേശങ്ങൾ
ഉപകരണങ്ങൾക്ക് പരിക്കേൽക്കുന്നതും കേടുപാടുകൾ സംഭവിക്കുന്നതും തടയാൻ ഇനിപ്പറയുന്ന സുരക്ഷാ മുൻകരുതലുകൾ എപ്പോഴും പാലിക്കുക:
- Ensure the station is connected to a properly grounded power outlet (230V).
- Do not touch the hot air nozzle or heated components directly. Use appropriate tools and allow components to cool.
- Operate the station in a well-ventilated area to dissipate fumes.
- Keep flammable materials away from the hot air stream.
- Disconnect the power cord before performing any maintenance or cleaning.
- Do not operate the station if the power cord or unit is damaged.
- This device is for professional use only. Keep out of reach of children.
സജ്ജമാക്കുക
- അൺപാക്ക് ചെയ്യുന്നു: പാക്കേജിംഗിൽ നിന്ന് എല്ലാ ഘടകങ്ങളും ശ്രദ്ധാപൂർവ്വം നീക്കം ചെയ്യുക. "ബോക്സിൽ എന്താണുള്ളത്" എന്ന വിഭാഗത്തിൽ ലിസ്റ്റ് ചെയ്തിരിക്കുന്ന എല്ലാ ഇനങ്ങളും നിലവിലുണ്ടെന്ന് ഉറപ്പാക്കുക.
- പ്ലേസ്മെൻ്റ്: Place the main unit on a stable, heat-resistant, and level surface. Ensure adequate clearance around the unit for ventilation.
- Connect Hot Air Tool: Connect the hot air tool's hose and electrical connector to the corresponding ports on the main unit. Ensure a secure connection.
- Connect Stand: Position the hot air tool stand near the main unit and place the hot air tool securely in its holder when not in use. The stand often includes a sensor to detect when the tool is placed, activating standby mode.
- പവർ കണക്ഷൻ: Plug the power cord into the main unit's power inlet, then connect it to a grounded 230V AC power outlet.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
1. പവർ ഓൺ/ഓഫ്
Press the power button located on the front panel to turn the station on or off. The digital display will illuminate upon startup.
2. Setting Temperature and Airflow
നാവിഗേഷൻ ബട്ടണുകൾ ഉപയോഗിക്കുക (+, -, OK) on the front panel to adjust the hot air temperature and airflow settings. The display shows the current and set values. The temperature range is typically 150°C to 450°C.
- താപനില: Adjust the desired hot air temperature for your application.
- എയർ ഫ്ലോ: Control the air volume output from the nozzle. Start with lower airflow for delicate components and increase as needed.
3. Using the Hot Air Tool
When the hot air tool is removed from its stand, the heating element will activate and the station will begin to reach the set temperature. When returned to the stand, the station will enter standby mode, cooling down the tool to a safe temperature.
- നിങ്ങളുടെ ആപ്ലിക്കേഷന് അനുയോജ്യമായ നോസൽ തിരഞ്ഞെടുക്കുക.
- Maintain a safe distance between the nozzle and the component to avoid overheating.
- Move the hot air tool in a circular motion to ensure even heating.
മെയിൻ്റനൻസ്
Regular maintenance ensures the longevity and optimal performance of your JBC JTSE-2QA station.
- വൃത്തിയാക്കൽ: Disconnect the power before cleaning. Use a soft, damp cloth to wipe down the exterior of the main unit and the hot air tool. Do not use abrasive cleaners or solvents.
- നോസൽ കെയർ: Periodically inspect the hot air nozzles for blockages or damage. Clean them as needed to ensure proper airflow.
- എയർ ഫിൽട്ടർ: Check and clean or replace the air filter (if applicable) according to the manufacturer's recommendations to maintain optimal airflow and prevent dust accumulation.
- സംഭരണം: Store the station in a clean, dry environment when not in use.
ട്രബിൾഷൂട്ടിംഗ്
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| Station does not power on. | No power supply; loose power cord. | Check power connection; ensure outlet is functional. |
| Hot air tool not heating. | Tool not properly connected; tool in stand (standby mode); faulty heating element. | Ensure tool is securely connected and removed from stand; contact support if element is faulty. |
| അപര്യാപ്തമായ വായുപ്രവാഹം. | Blocked nozzle; dirty air filter. | Clean or replace nozzle; check and clean/replace air filter. |
| Temperature fluctuations. | Sensor issue; unstable power supply. | Ensure stable power; contact support for sensor issues. |
സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | വിശദാംശങ്ങൾ |
|---|---|
| മോഡൽ നമ്പർ | JTSE-2QA |
| നിർമ്മാതാവ് | ജെബിസി |
| ഇൻപുട്ട് വോളിയംtage | 230 വോൾട്ട് എസി |
| താപനില പരിധി | 150 - 450 °C (302 - 842 °F) |
| അളവുകൾ (L x W x H) | 474 x 368 x 195 സെ.മീ |
| ഇനത്തിൻ്റെ ഭാരം | 4.1 Kilograms (4104 Grams) |
| ഉൾപ്പെടുത്തിയ ഘടകങ്ങൾ | ഹോട്ട് എയർ റീവർക്ക് സ്റ്റേഷൻ |
| ചാനലുകളുടെ എണ്ണം | 1 |
വാറൻ്റിയും പിന്തുണയും
For warranty information, technical support, or service inquiries regarding your JBC JTSE-2QA Digital Hot Air Rework Station, please contact JBC customer service or visit their official webവാറന്റി ക്ലെയിമുകൾക്കുള്ള വാങ്ങലിന്റെ തെളിവായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.
ജെബിസി ഉദ്യോഗസ്ഥൻ Webസൈറ്റ്: www.jbctools.com