FNIRSI DST-210 Handheld Oscilloscope, Multimeter, and DDS Signal Generator

Прирачник за корисничко упатство

Вовед

The FNIRSI DST-210 is a compact and powerful 3-in-1 device designed for a wide range of electrical and electronic testing applications. It integrates the functionalities of a digital oscilloscope, a true RMS digital multimeter, and a DDS signal generator into a single handheld unit. This manual provides detailed instructions for its setup, operation, and maintenance.

Што има во кутијата

  • DST-210 DMM Scope (1)
  • Сонда P6100 (1)
  • Multimeter Test Leads (1)
  • Alligator Clip Probe (1)
  • USB Data Cable (1)
  • Упатство за употреба (1)
Contents of the FNIRSI DST-210 box including the device, probes, cables, and user guide.

Figure 1: All components included in the FNIRSI DST-210 package.

Поставување

1. Полнење на уредот

Before initial use, fully charge the device using the provided Type-C USB cable. Connect the cable to the Type-C port on the side of the device and to a 5V 1A power source. The battery indicator on the screen will show charging status. A full charge typically takes approximately 3 hours for the 3000mAh battery.

2. Првично вклучување и избор на јазик

Press and hold the power button on the side of the device to turn it on. Upon first power-on, you will be prompted to select your preferred language. Use the navigation buttons to select 'English' and press 'ENTER'.

3. Connecting Probes

The DST-210 supports various probes for its different functions:

  • Multimeter Probes: Insert the red and black multimeter test leads into the corresponding input jacks at the bottom of the device (VΩHz for red, COM for black).
  • Oscilloscope Probe: Connect the P6100 oscilloscope probe to the BNC connector labeled 'DSO' on the top of the device. Ensure the probe's attenuation switch is set correctly (e.g., 1X or 10X) to match the device's settings.
  • Signal Generator Probe: Connect the alligator clip probe to the 'DDS' BNC connector on the top of the device for signal output.
FNIRSI DST-210 device with all probes and cables connected, showing its 3-in-1 functionality.

Figure 2: FNIRSI DST-210 with all probes connected for various functions.

Работни режими

The DST-210 offers three primary operating modes: Multimeter, Oscilloscope, and Signal Generator. Use the rotary dial to select the desired mode from the main interface.

1. Режим на мултиметар

This mode provides comprehensive digital multimeter functionalities with 19999 counts. It supports auto-ranging for most measurements.

  • Мерења: DC/AC Voltage, DC/AC Current, Resistance, Capacitance, Frequency, Diode Test, Continuity Test, Live/Neutral Wire Detection.
  • Операција: Rotate the dial to the 'Multimeter' position. The device will automatically attempt to detect the measurement type. Use the navigation buttons to manually select specific measurement types (e.g., AC Voltage vs. DC Voltage) if needed.
  • Карактеристики: Curve recording, Max/Min value display, Data hold, Auto power-off.
FNIRSI DST-210 displaying various multimeter measurements including AC/DC Voltage, Continuity, AC/DC Current, and Resistance.

Figure 3: Multimeter mode displaying various measurement types.

Video 1: Demonstration of FNIRSI DST-210's multimeter functions, including various measurements and probe usage.

2. Режим на осцилоскоп

The oscilloscope function allows for waveform visualization and analysis with a 10MHz bandwidth and 48MSa/s sampстапка на линг.

  • Мерења: Real-time waveform display, Frequency, Period, Duty Cycle, Vpp, Vmax, Vmin, Vrms, Average.
  • Операција: Rotate the dial to the 'Oscilloscope' position. Connect the oscilloscope probe to the circuit under test. Use the navigation buttons to adjust vertical sensitivity (V/div) and horizontal time base (S/div). The 'AUTO' button can automatically optimize display settings.
  • Карактеристики: Support trigger level display, infinite persistence, waveform storage and export.
FNIRSI DST-210 in oscilloscope mode, showing waveform analysis for CAN Bus verification, audio analysis, and power checks.

Figure 4: Oscilloscope mode demonstrating waveform analysis capabilities.

Видео 2: Надview of the FNIRSI DST-210's oscilloscope features and real-time waveform display.

3. DDS Signal Generator Mode

The built-in DDS signal generator can output 13 types of waveforms for various testing and simulation purposes.

  • Бранови форми: Sine Wave, Square Wave, Sawtooth Wave, Half-Wave, Full-Wave, Step Wave, Reverse Step Wave, Index Up, Index Decrease, Direct Current, Multi-Audio, Sink Pulse, Lorentz Wave.
  • Операција: Rotate the dial to the 'Signal Generator' position. Connect the alligator clip probe to the circuit where the signal is needed. Use the navigation buttons to select the desired waveform type, adjust frequency (0-50KHz), duty cycle (0-100%), and amplitude (0.1V-3.0V).
FNIRSI DST-210 displaying various signal generator waveforms including Sine, Square, Sawtooth, and Half-Wave.

Figure 5: Signal Generator mode showing different waveform outputs.

Одржување

1. Батерија и полнење

The device is powered by a 3000mAh lithium battery. Charge it using the Type-C port (5V 1A). The battery icon on the screen indicates the charge level. For optimal battery life, avoid fully discharging the device frequently.

2. Auto Power-Off

To conserve battery, the device features an auto power-off function. This can be configured in the 'System Settings' menu. Options typically include 15 minutes, 30 minutes, 1 hour, or disabled.

3. Поставки за приказ

The 2.8-inch TFT color screen offers adjustable backlight brightness and theme options (Daylight/Night). These settings can be accessed via the 'System Settings' menu to enhance visibility in different lighting conditions.

FNIRSI DST-210's display showing day and night themes, waveform storage, rotary dial, and battery information.

Figure 6: System settings interface for display and power management.

4. Firmware Updates and USB Sharing

The device supports firmware updates and USB data sharing. Check the manufacturer's website (www.fnirsi.cn) for the latest firmware and instructions. USB sharing allows for waveform data export to a computer.

Решавање проблеми

  • Уредот не се вклучува: Проверете дали батеријата е наполнета. Поврзете ја со полнач од тип C и обидете се повторно.
  • No reading in Multimeter mode: Check that the probes are securely connected and that the correct measurement mode is selected for the circuit under test.
  • Unstable waveform in Oscilloscope mode: Adjust the trigger level and time base settings. Ensure proper probe connection and attenuation settings.
  • Signal Generator not outputting: Verify the probe is connected to the 'DDS' port and that the desired waveform, frequency, and amplitude are configured.
  • Screen issues (e.g., flickering, unresponsiveness): Try a factory reset via the 'System Settings' menu. If the issue persists, contact customer support.

Спецификации

ПараметарВредност
Во реално време Сampling Стапка48MSa / s
Аналоген пропусен опсег10 MHz
Влезна импеданса1MΩ
Режим на спојувањеAC/DC
Тест томtage Опсег (1:1 Сонда)80Vpp (±40V)
Тест томtage Опсег (10:1 Сонда)800Vpp (±400V)
Вертикална чувствителност10mV/див - 10V/див
Временска база на ниво500ns ~ 20s
Бројачи на мултиметри19999
DDS Waveform Frequency0-50 KHz
Материјал на екранот2.8 инчен TFT екран во боја
Батерија3000 mAh
Големина на производот≈177.43×87.47×34.5мм
Нето Тежина≈300гр