MiraBox M3 Stream Dock Controller User Guide

MiraBox-logo

MiraBox M3 Stream Dock Controller

MiraBox-M3-Stream-Dock-Controller-product

Technical Parameters

Specification Details
Product Name Stream Dock M3
Basic Configurations 15 LCD Keys 3 Dial Knobs Working Voltage: 5V Connection Type: Wired (USB)
Dimensions 151 * 80 * 43.6 mm
Keycap Material Acrylic + Magnet
Enclosure Material ABS (Upper & Lower Covers, Positioning Plate)
Package Accessories 1 x M3 Console 1 x Base Bracket 1 x USB Type-A to Type-C Cable 1 x User Manual
Cable Length 1.5 meters
Color Options Black / White
Supported Operating Systems Windows 10 (64-bit) or newer macOS 11 or newer

Operating Instruction

  1. Download and install the Stream Dock application.MiraBox-M3-Stream-Dock-Controller-fig (1)
  2. Connect the Stream Dock keyboard to the USB port on your PC or Mac and open the software.
    • It is not recommended to use USB hubs/docking stations.
    • It is recommended to use USB 3.0.MiraBox-M3-Stream-Dock-Controller-fig (2)
  3. Launch the Stream Dock application, operate from the right panel and drag them to the left button area to define functions. You can also double-click the operation on the right panel, and the function will be automatically added to the blank area of the left button.MiraBox-M3-Stream-Dock-Controller-fig (3)
  4. Use custom icons to configure your buttons and personalize the keys. For the best visual effect, please use 126 x 126 pixel png(Jpg/gif format fileMiraBox-M3-Stream-Dock-Controller-fig (4)
    • You can open the icon settings by right-clicking, select the icon replacement method, or directly drag the image file onto the icon to achieve a faster icon replacement.MiraBox-M3-Stream-Dock-Controller-fig (5)
  5. Right-click the icon to copy, paste or delete the function.MiraBox-M3-Stream-Dock-Controller-fig (6)
  6. You can right-click in the software’s background setting area to open the background setting. By selecting a custom background file, you can achieve the effect of background switching. For the best visual effect, please use 1920*1080 pixel png/jpg/gif/MP4 format files. MiraBox-M3-Stream-Dock-Controller-fig (7)
  7. You can download a large number of plug-ins, icons, scenes and other resources in the Space. The downloaded plug-ins will be automatically added to the right panel, the icon files will be saved to the icon library, and the scene files will be automatically added to your scene list. (The imported scene file needs to be consistent with your device model; otherwise it cannot be imported.)MiraBox-M3-Stream-Dock-Controller-fig (8)
  8. In the favorite websites scene, we have preset a button for you to quickly obtain video tutorials.MiraBox-M3-Stream-Dock-Controller-fig (9)
  9. Use the matching base bracket to make the Stream Dock get better support.MiraBox-M3-Stream-Dock-Controller-fig (10)
  10. The key activation of the M3 relies on precise detection of magnetic field changes. During device shipping or daily use, the key area may be affected by external magnetic interference, causing magnetic baseline drift. This can result in keys failing to activate when pressed – a normal occurrence that can be resolved by recalibrating the key magnetic field.

Follow these steps for magnetic calibration: 

  1. Place the Stream Dock M3 on a flat, stable surface away from any sources of strong magnetic interference.
  2. Connect the device directly to your computer using the USB cable.
  3. Navigate to: Stream Dock App > Settings > Device > Key Field Calibration and click to begin.
    1. Step 1: All 15 LCD keys will sequentially illuminate in blue.
    2. Step 2: When the first key transitions from blue to red, press and hold it down for 3 seconds. It will turn green once successfully calibrated.
    3. Step 3: Repeat this press-and-hold sequence for the remaining 14 keys as they light up.
    4. Step 4: Once complete, test all keys to confirm accurate registration and activation.

Note: If the calibration is interrupted (such as due to a power outage or accidental cable disconnect), simply disconnect the device, reconnect it, and restart the calibration sequence.MiraBox-M3-Stream-Dock-Controller-fig (11)

Troubleshooting

  1. Some key presses are not detected (Stream Dock M3): This can occur due to external magnetic interference causing magnetic baseline drift. Recalibrate the key magnetic field following the calibration steps in the manual.
  2. Calibration doesn’t complete: If calibration is interrupted (for example, power outage or accidental USB cable disconnect), disconnect the device, reconnect it, and restart the calibration sequence.

Documents / Resources

PDF thumbnailM3 Stream Dock Controller
User Guide · Stream Deck dock controller, M3, stream dock, M3 Stream Dock Controller, Stream Dock Controller, Dock Controller

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.