MICROTECH-logo

MICROTECH IP67 Wireless Offset Centerline Caliper

MICROTECH-IP67-Wireless-Offset-Centerline-Caliper-product-image

Specifications
  • Brand: MICROTECH
  • Model: Offset Centerline Caliper IP67
  • Wireless Connectivity: WIRELESS TO MDS, WIRELESS HID+MAC
  • Calibration Standards: ISO 17025:2017, ISO 9001:2015
  • Battery Type: CR2032
  • IP Rating: IP67

Product Usage Instructions

Initial Setup

  1. Wipe the measuring surfaces with a clean cloth soaked in gasoline to remove anti-corrosion oil.
  2. Insert the CR2032 battery into the caliper, ensuring correct polarity.
  3. The caliper has an Autoswitch on/off function; move the electronic module to switch it on.

Measurement Process

  • Ensure measuring jaws sum to the measured object without knocking.
  • Avoid warps on measuring surfaces and ensure full contact with the object.

Battery Replacement
Replace the CR2032 battery when needed, following proper safety precautions.

Button Functions
Use the MODE button to select different wireless data transfer modes.

Wireless Data Transfer

  • Switch on the wireless module by pressing the button for 2 seconds.
  • Select the desired transfer mode (STANDARD or ECO) for data transfer.
  • Use the buttons on the caliper or the app to save data.

Downloading MDS App
Download the MICROTECH MDS app from www.microtech.tools for various platforms.

Frequently Asked Questions (FAQ)
  • Q: What battery type does the caliper use?
    • A: The caliper uses a CR2032 battery for operation.
  • Q: How do I switch on the wireless data transfer mode?
    • A: Press the wireless module button for 2 seconds to activate the wireless data transfer mode.
  • Q: Where can I download the MICROTECH MDS app?
  • Q: How should I clean the caliper for maintenance?
    • A: Wipe the measuring surfaces with a clean cloth soaked in gasoline to remove anti-corrosion oil.

MICROTECH
WWW.MICROTECH.TOOLS

WIRELESS OFFSET CENTERLINE CALIPER IP67

USER MANUAL

MICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (1)

Item No Range Resolution Accuracy Anvil D Protection Preset
standard option
mm inch mm μm mm mm
141730154 10-160 0.4-6.4” 0,01 ±30 10 20, 35 IP67
141730204 10-210 0.4-8.4”
141730304 10-310 0.4-12.4”

MODIFICATIONS

MICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (2)

OPERATION INSTRUCTIONS

OFFSET CENTERLINE calipers equipped with special jaws for measuring center to center distance.
Wipe with a clean cloth, soaked in gasoline, measuring surface of the frame and gauge calipers to remove anti-corrosion oil. If necessary, open the battery cover; insert the battery (type CR2032) according to the polarity of the electrodes.

This caliper has Autoswitch on/ off function

  • move electronic module for switch on caliper
  • after 10 minutes without any moving caliper will switch off

During the measurement, measuring jaws should to sum to the measured object without knocking.
During the measurement avoid warps of measuring surfaces of the instrument. Measuring surface must be fully in contact with the measurement object

MICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (3)

WARNING!
IN THE PROCESS OF WORKING WITH CALIPERS SHOULD BE AVOIDED: Scratches on the measuring surfaces
Measuring the size of object in the process of machining
Shocks or dropping, avoid bending of rod or other surfaces.

BUTTON FUNCTIONS

MICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (4)

POWER CONSUMPTION

MODE TRANSFER DATA
WIRELESS OFF 45 μA
WIRELESS TO MDS STANDARD 2.0 mA
ECO (GATT) 45-100 μA
WIRELESS HID 0.4 mA
WIRELESS HID+MAC 0.4 mA

WIRELESS DATA TRANSFER MODES
MICROTECH caliper with Built-in Wireless data output module for transfer results

MICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (5)

WIRELESS DATA TRANSFER CONNECTION

  • SWITCH ON WIRELESS module pushMICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (6) button 2 sec;
  • In WIRELESS TO MDSMICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (7) non-stop blinking on display up to connection to MDS app  and selecting STANDARD or ECO sub-mode.
  • ECO recommended for battery economy
  • In STANDARD sub mode data transfer 4 times/sec and  MICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (7)all time on display.
  • PushMICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (6) button to save data to MDS app or use buttons and Timer inside app. In ECO (GATT) sub mode caliper ready to transfer data any time with no indication. Push button to save data on MDS app.
  • For selecting next mode pushMICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (6) 5 sec.
  • WIRELESS HID and WIRELESS HID+MAC MICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (7) blinking 2 sec on display and will be ready  for searching on Tablet, Smartphone or Computer Bluetooth connections. After successful connection save data to customers app with pushMICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (6) button.

DOWNLOAD MICROTECH MDS APP
Link to to Download MICROTECH MDS app for Windows, Android, iOS, MAcOS on www.microtech.tools

MICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (8)

VIDEO MANUAL
Video manual with Connection on MICROTECH YouTube https://www.youtube.com/@Microtech-Instrumentsor by QR code scanning

MICROTECH-IP67-Wireless-Offset-Centerline-Caliper-image (9)

Changing without prior notice

Documents / Resources

MICROTECH IP67 Wireless Offset Centerline Caliper [pdf] User Manual
141730154, 141730304, IP67 Wireless Offset Centerline Caliper, IP67, Wireless Offset Centerline Caliper, Offset Centerline Caliper, Centerline Caliper, Caliper

References

Leave a comment

Your email address will not be published. Required fields are marked *