Features:
- 1000VDC I/O isolation
- Internal SMD technology
- Built-in EMI filter
- Cooling by free air convection
- Non-conductive plastic case
- Dual in line package
- 100% burn-in test
- Low cost / High reliability
- Approvals: FCC /EAC/CE/UKCA
- 2 years warranty
SELECTION GUIDE
ORDER NO. | SUSO1L-05 | SUSO1M-05 | SUSO1N-05 | SUS010-05 | SUSO1L-09 | SUSO1M-09 | SUSO1N-09 | SUS010-09 | |||
DC OUTPUT VOLTAGE | 5V | 9V | |||||||||
OUTPUT CURRENT RANGE | 0 – 200mA | 0 – 111mA | |||||||||
EFFICIENCY | 73% | 74% | 72% | 74% | 75% | 79% | 80% | 77% |
ORDER NO. | SUSO1L-12 | SUSO1M-12 | SUSO1N-12 | SUS010-12 | SUSO1L-15 | SUSO1M-15 | SUSO1N-15 | SUS010-15 | |||
DC OUTPUT VOLTAGE | 12V | 15V | |||||||||
OUTPUT CURRENT RANGE | 0 – 84mA | 0 – 67mA | |||||||||
EFFICIENCY | 78% I82% I83% | 83% | 79% 182% | 83% | 83% |
SPECIFICATION
OUTPUT | RATED POWER | 1W | ||||||||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | |||||||||
LINE REGULATION Note.3 | ±1.2% for 1% input variation | |||||||||
LOAD REGULATION Note.4 | ±8.0% | |||||||||
VOLTAGE ACCURACY | ±2.0% | |||||||||
SWITCHING FREQUENCY | 50KHz min. | |||||||||
INPUT | VOLTAGE RANGE | 4.5 – 5.5V | 10.8 -13.2V | 21.6 – 26.4V | 43.2 – 52.8V | 4.5 – 5.5V | 10.8 -13.2V | 21.6 – 26.4V | 43.2 – 52.8V | |
NORMAL VOLTAGE | 5V | 12V | 24V | 48V | 5V | 12V | 24V | 48V | ||
INPUT CURRENT | Full load | 280mA | 112mA | 55mA | 28mA | 280mA | 112mA | 55mA | 28mA | |
No load | 21mA | 11mA | 10mA | 3mA | 21mA | 11mA | 10mA | 3mA | ||
FILTER | Capacitor type | |||||||||
PROTECTION | Fuse recommended | |||||||||
PROTECTION | OVERLOAD | Momentary | ||||||||
Protection type : Broken | ||||||||||
SHORT CIRCUIT Momentary |
||||||||||
Protection type : Broken | ||||||||||
ENVIRONMENT | WORKING TEMP. | -25 – +71 c (Refer to “Derating Curve”) | ||||||||
WORKING HUMIDITY | 20% – 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -25 – +105 c , 10 – 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03% / t (0 – 50’C) | |||||||||
VIBRATION | 10 – 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC | SAFETY STANDARDS | EAC TP TC 020/2011 approved | ||||||||
WITHSTAND VOLTAGE | 1113-0/P:1.5KVOC | |||||||||
ISOLATION RESISTANCE | IIP-0/P: 100M Ohms / 500VDC/ 25°C/ 70% RH | |||||||||
ISOLATION CAPACITANCE | 80pF max. | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 Class B, FCC part 15 Class B, EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A, EAC TP TC 020 | |||||||||
OTHERS | MTBF | 700khrs min. MIL-HDBK-217F(25°C) | ||||||||
DIMENSION | 22.6’9.91.9mm or 0.89’1’0.39’1’0.35′ inch (L’W*H) | |||||||||
WEIGHT | 3.1g |
Mechanical Specification
Pin Configuration
Pin No. | Output |
1 & 16 | +Vin |
6 & 11 | -Vout |
7 & 10 | +Vout |
8 & 9 | -Vin |
Derating Curve
NOTE
- All parameters are specified at normal input, rated load, 25’C 70% RH ambient.
- Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a O.1uf & 47uf capacitor.
- Line regulation is measured from low line to high line at rated load.
- Load regulation is measured from 20% to 100% rated load.
Product Liability Disclaimer : For detailed information, please refer to https://vww.meanwell.com/serviceDisclaimer.aspx
File Name: SUS01-SPEC 2022-03-16