■ Features:

  • 2:1 wide input range
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • 1500VAC I/O isolation
  • Forced air cooling by built-in DC Fan
  • 100% full load burn-in test
  • 24V and 48V input voltage design refer to LVD
  • 2 years warranty

SPECIFICATION

MODEL SD-350B SD-350C
OUTPUT DC VOLTAGE 5V 12V 24V 48V 5V 12V 24V 48V
RATED CURRENT 57A 27.5A 14.6A 7.3A 60A 27.5A 14.6A 7.3A
CURRENT RANGE 0 – 5M 0 – 27.5A 0 – 14.6A 0 – 7.3A 0 – 60A 0 – 27.5A 0 – 14.6A 0 – 7.3A
RATED POWER 285W 330W 350.4W 350.4W 300W 330W 350.4W 350.4W
RIPPLE & NOISE (max.) Note/ 100mVp-p 120mVp-p 150mVp-p 200mVp-p 100mVp-p 120mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 4.5 – 5.5VDC 11 – 16VDC 23 – 30VDC 43 – 53VDC 4.5 – 5.5VDC 11 – 16VDC 23 – 30VDC 43 – 53VDC
VOLTAGE TOLERANCE Not4.3 ±2.0% 31.% ±1.0% ±1.0% ±2.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.3% ±0.2% ±0.2% 31.% ±0.3% ±0.2% ±0 2%
LOAD REGULATION ±1.0% 31.% 31.% ±1.0% ±1.0% ±1.0% 31.% ±1.0%
SETUP, RISE TIME 300ms, 50ms at full load
INPUT VOLTAGE RANGE 8:19 – 36VDC C:36 – 72VDC D:72 -144VDC
EFFICIENCY (Typ.) 74% 80% 80% 84% 76% 81% 81% 82%
DC CURRENT (Typ.) 14.4A/24V 16A/24V 17.6A/24V 17.6A/24V 7.6A/48V 8.8A/48V 9.0A148V 9.0A148V
INRUSH CURRENT (Typ.) C:45N48VDC D:45A/96VDC
PROTECTION OVERLOAD 105 – 135% rated output power
Protection type : Shut down olp voltage, re-power on to recover
OVER VOLTAGE 5.75 – 6.75V 1 16.8 – 20V 1 31.5 – 37.5V 1 53 – 65V 1 5.75 – 6.7W 1 16.8 – 20V 1 31.5 – 37.5V 1 53 – 65V
Protection type : Shut down o/p voltage. re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
EWIROMIENI WORKING TEMP. -20 – +60°C (Refer to ‘Derating Curve)
WORKING HUMIDITY 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 – +85°C, 10 – 95% RH
TEMP. COEFFICIENT ±0.03%/t (0 – 50°C)
VIBRATION 10 – 500Hz, 2G 10min./1cycle, 60min. each along X. V, Z axes
SAFETY & EMC
(Note 4)
SAFETY STANDARDS EAC TP TC 004 approved, design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE I/P-01P:1.5KVAC 1/P-Fa2KVAC 0/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-0/P, NP-FG, 0/P-FG:100M Ohms / 500VDC 125°C/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020
EMC IMMUNITY Compliance to BS EWEN61000-4-2,3,4,6,8, 8S EN/EN55035, light industry level, EAC TP TC 020
OTHERS MTBF 1705.6K hrs min. Telcordia SR-332 (Bellcore) ; 263.9K hrs min. MIL-HDBK-217F (25t )
DIMENSION 215’115’50mm (L’W’H)
PACKING 1.1Kg; 12pcs/14.4Kg10.9CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 2OMHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  5. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft)
    Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

SPECIFICATION

MODEL SD-350D
OUTPUT DC VOLTAGE 5V 12V 24V 48V
RATED CURRENT 60A 29.2A 14.6A 7.3A
CURRENT RANGE 0 – 60A 0 – 29.2A 0 – 14.6A 0 – 7.3A
RATED POWER 300W 350.4W 350.4W 350.4W
RIPPLE & NOISE (max.) Note/ 100mVp-p 120mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 4.5 – 5.5VDC 11 – 16VDC 23 – 30VDC 43 – 53VDC
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.3% ±0.2% ±0.2%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 300ms, 50ms at full load
INPUT VOLTAGE RANGE B:19 – 36VDC C:36 – 72VDC D:72 -144VDC
EFFICIENCY (Typ.) 78% 83% 87% 89%
DC CURRENT (Typ.) 6A196V 6N96V 6N96V 6N96V
INRUSH CURRENT (Typ.) C:45N4BVDC D:45A/96VDC
PROTECTION OVERLOAD 105 -135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE 5.75 – 6.75V 1 16.8 – 20V 31.5 – 37.5V 153 – 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
ENVIROMEK WORKING TEMP. -20 – +60°C (Refer to ‘Derating Curve’)
WORKING HUMIDITY 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 – +85°C, 10 – 95% RH
TEMP. COEFFICIENT ±0.03%/°C (0 – 50°C)
VIBRATION 10 – 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY &
EMC (Note 4)
SAFETY STANDARDS IECIBS EN/EN 62368-1, EAC TP TC 004 approved, design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE I/P-0/P:1.5KVAC 1/P-Fa2KVAC 0/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, 0/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION Compliance to BS EN/EN55022 (CISPR22) Class B, EAC TP TC 020
EMC IMMUNITY Compliance to BS ENEN61000-4-2,3,4,6,8, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS MTBF 1705.6K hrs min. Tetcordia SR-332 (Bellcore) ; 263.9K hrs min. MIL-HDBK-217F (25-C )
DIMENSION 215’115’50mm (L’W’H)
PACKING 1.1Kg; 12pcs/14.4Kg/0.9CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20OMHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  5. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft)
    Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN WELL SD 350 Series 350W Single Output DC DC Converter - Mechanical Specification

Terminal Pin No. Assignment :

Pin No. Assignment Pin No. Assignment
1 DC INPUT V+ 4,5,6 DC OUTPUT V-
2 DC INPUT V- 7,8,9 DC OUTPUT V+
3 FG –Earth

Block Diagram

MEAN WELL SD 350 Series 350W Single Output DC DC Converter - Diagram

Derating Curve

MEAN WELL SD 350 Series 350W Single Output DC DC Converter - Derating Curve 1

Static Characteristics

MEAN WELL SD 350 Series 350W Single Output DC DC Converter - Derating Curve 2

File Name:SD-350-SPEC 2022-09-20