MEAN WELL RSP-200 series 200 Watt Single Output with PFC Function Instruction Manual
Features
- Universal AC input/ Full range
- Built-in active PFC function
- High efficiency up to 90%
- Cooling by free air convection
- Protections: Short circuit / Overload/Over voltage / Over temperature
- Optional conformal coating
- LED indicator for power on
- 3 years warranty
Description
RSP-200 is a 200W single output enclosed type AC/DC power supply. This series operates for 88~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection, working for the temperature up to 70°C.
Model Encoding / Order Information
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- RF application
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL | RSP-200-2.5 | RSP-200-3.3 | RSP-200-4 | RSP-200-5 | RSP-200-7.5 | RSP-200-12 | |
OUTPUT | DC VOLTAGE | 2.5V | 3.3V | 4V | 5V | 7.5V | 12V |
RATED CURRENT | 40A | 40A | 40A | 40A | 26.7A | 16.7A | |
CURRENT RANGE | 0 ~ 40A | 0 ~ 40A | 0 ~ 40A | 0 ~ 40A | 0 ~ 26.7A | 0 ~ 16.7A | |
RATED POWER | 100W | 132W | 160W | 200W | 200.25W | 200.4W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 2.35 ~ 2.85V | 2.97 ~ 3.8V | 3.7 ~ 4.3V | 4.5 ~ 5.5V | 6 ~ 9V | 10 ~ 13.2V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.3% | |
LOAD REGULATION | ±1.5% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±0.5% | |
SETUP, RISE TIME | 1500ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 8ms at full load 230VAC /115VAC | ||||||
INPUT | VOLTAGE RANGE Note.4 | 88 ~ 264VAC 124 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||||
EFFICIENCY (Typ.) | 79.5% | 81.5% | 84% | 85.5% | 89% | 89% | |
AC CURRENT (Typ.) | 2A/115VAC 1.1A/230VAC | 2.5A/115VAC 1.3A/230VAC | |||||
INRUSH CURRENT (Typ.) | 20A/115VAC 40A/230VAC | ||||||
LEAKAGE CURRENT | <1mA / 240VAC | ||||||
PROTECTION | OVERLOAD | 105 ~ 135% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 2.88 ~ 3.5V | 3.8 ~ 4.62V | 4.5 ~ 5.6V | 5.75 ~ 7V | 9.4 ~ 10.9V | 13.8 ~ 16.2V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 45℃) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC(Note 5) | SAFETY STANDARDS | UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004, CCC GB4943.1,BSMI CNS14336-1, AS/NZS 60950.1 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1 | ||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 | ||||||
OTHERS | MTBF | 2078.1K hrs min. Telcordia SR-332 (Bellcore) ; 224.5K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 215*115*30mm (L*W*H) | ||||||
PACKING | 0.72Kg; 15pcs/11.8Kg/0.67CUFT | ||||||
NOTE |
|
MODEL | RSP-200-13.5 | RSP-200-15 | RSP-200-24 | RSP-200-27 | RSP-200-36 | RSP-200-48 | |
OUTPUT | DC VOLTAGE | 13.5V | 15V | 24V | 27V | 36V | 48V |
RATED CURRENT | 14.9A | 13.4A | 8.4A | 7.5A | 5.56A | 4.2A | |
CURRENT RANGE | 0 ~ 14.9A | 0 ~ 13.4A | 0 ~ 8.4A | 0 ~ 7.5A | 0 ~ 5.56A | 0 ~ 4.2A | |
RATED POWER | 201.15W | 201W | 201.6W | 202.5W | 200.16W | 201.6W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 220mVp-p | 240mVp-p | |
VOLTAGE ADJ. RANGE | 12 ~ 15V | 13.5 ~ 18V | 20 ~ 26.4V | 26 ~ 31.5V | 32.4 ~ 39.6V | 41 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% | ±0.2% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1500ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 8ms at full load 230VAC /115VAC | ||||||
INPUT | VOLTAGE RANGE Note.4 | 88 ~ 264VAC 124 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||||
EFFICIENCY (Typ.) | 89% | 89.5% | 89.5% | 89% | 90% | 90% | |
AC CURRENT (Typ.) | 2.5A/115VAC 1.3A/230VAC | ||||||
INRUSH CURRENT (Typ.) | 20A/115VAC 40A/230VAC | ||||||
LEAKAGE CURRENT | <1mA / 240VAC | ||||||
PROTECTION | OVERLOAD | 105 ~ 135% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 15.7 ~ 18.4V | 18.8 ~ 21.8V | 27.6 ~ 32.4V | 32.9 ~ 38.3V | 41.4 ~ 48.6V | 58.4 ~ 68V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 45℃) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC(Note 5) | SAFETY STANDARDS | UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004, CCC GB4943.1,BSMI CNS14336-1, AS/NZS 60950.1 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1 | ||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 | ||||||
OTHERS | MTBF | 2078.1K hrs min. Telcordia SR-332 (Bellcore) ; 224.5K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 215*115*30mm (L*W*H) | ||||||
PACKING | 0.72Kg; 15pcs/11.8Kg/0.67CUFT | ||||||
NOTE |
|
Mechanical Specification
Terminal Pin No. Assignment :
Pin No. | Assignment | Pin No. | Assignment |
1 | AC/L | 4~6 | DC OUTPUT -V |
2 | AC/N | 7~9 | DC OUTPUT +V |
3 | FG |
Block Diagram
PFC fosc : 100KHz
PWM fosc : 100KHz
Derating Curve
Static Characteristics
Documents / Resources
![]() |