MEAN WELL - logo25W Single Output Switching Power Supply
RS-25 seriesMEAN WELL RS-25 Series Single Output Switching Power SupplyGTIN CODE MW Search
https://www.meanwell.com/serviceGTIN.aspx

Features :

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105t long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70t
  • Withstand 5G vibration test
  • No load power consumption<0.5W
  • High efficiency, long life and high reliability
  • 3 years warranty

MEAN WELL RS-25 Series Single Output Switching Power Supply - qr codehttps://www.meanwell.com/Upload/PDF/Enclosed_Type_EN.pdf

SPECIFICATION

MODEL RS•25-3.3 RS•25•5 RS•25•12 RS•25•15 RS•25-24 RS-25-48
OUTPUT DC VOLTAGE 3.3V 5V 12V 15V 24V 48V
RATED CURRENT 6A 5A 2.1A 1.7A 1.1A 0.57A
CURRENT RANGE 0 – 6A 0 – 5A 0 – 2.1A 0 – 1.7A 0 – 1.1A 0 – 0.57A
RATED POWER 19.8W 25W 25.2W 25.5W 26.4W 27.36W
RIPPLE & NOISE (max.) Natal 80mVp-p BOmVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 2.85 – 3.6V 4.75 – 5.5V 10.8 – 13.2V 13.5 – 16.5V 22 – 27.6V 42 – 54V
VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION Note.3 ±2.0% ± 1.0% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 1800ms, 23ms/230VAC 4000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 80ms/230VAC 14ms/115VAC at full load
INPUT VOLTAGE RANGE 88 – 264VAC 125 – 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 – 63Hz
EFFICIENCY(Typ.) 74.% 179.% 182.% 184.% I86% I85%
AC CURRENT (Typ.) 0.7A/115VAC 0.4A/230VAC
INRUSH CURRENT (Typ.) COLD START 45A/230VAC
LEAKAGE CURRENT <2mA/ 240VAC
PROTECTION OVERLOAD 110 -180% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 3.8 – 4.45V I 5.75 – 6.75V 1 13.8 – 16.2V 1 17.25 – 20.25V I 27.6 – 32.4V I 55.2 – 64.8V
Protection type : Shut off o/p voltage, damping by zener diode
ENVIRONMENT WORKING TEMP. -20 – +70t (Refer to ‘Derating Curve’)
WORKING HUMIDITY 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 – +85t , 10 – 95% RH
TEMP. COEFFICIENT ±0.03%1°C (0 – 50°C)
VIBRATION 10 – 500Hz. 5G 10min./1cycle. period for 60min. each along X. Y, Z axes
SAFETY &
EMC (Note 6)
SAFETY STANDARDS UL62368-1, TUV BS EN1EN62368-1 , AS/NZS 62368.1, EAC TP TC 004, CCC 064943.1, BSMI CNS14336-1, BIS IS13252(Part1):201011EC 60950-1: 2005 approved
WITHSTAND VOLTAGE UP-0/P:3KVAC UP-FG:2KVAC 0/P-FG:0.5KVAC
ISOLATION RESISTANCE 11P-0/P, UP-FG, O!P-FG:100M Ohms! 500VDC / 25°C/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2.-3,G69254 class 6.GB17625.1, EAC TP TC 020, CNS13438 Class B
EMC IMMUNITY Compliance to 6S EN/EN61000-4-2,3,4,5,6,8,11, BS EN1EN55035, light industry level, EAC TP TC 020
OTHERS MTBF 3992.0K hrs min. Telcordia SR-332 (Bellcore) ; 663.3K firs min. MIL-HDBK-217F (25t )
DIMENSION 78*51’28mm (L*W•H)
PACKING 0.2Kg; 60pcs/13Kg10.46CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25-C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 rt F & 47 If F parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high Me at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power sum is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.’
(as available on https://Awnv.meanwell.com//Upbad/PDF/EMIfitatement_en.pdf )
7. The ambient temperature derating of 3.5-C/1000m with fanless models and of 5.C/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability Disdains. : For detailed information, please refer to https://wvmmeanwell.com/serviceDisciaimeraspx

Mechanical Specification

MEAN WELL RS-25 Series Single Output Switching Power Supply - Specification

Block Diagram

MEAN WELL RS-25 Series Single Output Switching Power Supply - Diagram

Derating Curve

MEAN WELL RS-25 Series Single Output Switching Power Supply - Curve

Output Derating VS Input Voltage

MEAN WELL RS-25 Series Single Output Switching Power Supply - Voltage

Documents / Resources

MEAN WELL RS-25 Series Single Output Switching Power Supply [pdf] Owner's Manual
RS-25 Series Single Output Switching Power Supply, RS-25 Series, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply

References

Leave a comment