Features :
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 105t long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 70t
- Withstand 5G vibration test
- No load power consumption<0.5W
- High efficiency, long life and high reliability
- 3 years warranty
https://www.meanwell.com/Upload/PDF/Enclosed_Type_EN.pdf
SPECIFICATION
MODEL | RS•25-3.3 | RS•25•5 | RS•25•12 | RS•25•15 | RS•25-24 | RS-25-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 5V | 12V | 15V | 24V | 48V |
RATED CURRENT | 6A | 5A | 2.1A | 1.7A | 1.1A | 0.57A | |
CURRENT RANGE | 0 – 6A | 0 – 5A | 0 – 2.1A | 0 – 1.7A | 0 – 1.1A | 0 – 0.57A | |
RATED POWER | 19.8W | 25W | 25.2W | 25.5W | 26.4W | 27.36W | |
RIPPLE & NOISE (max.) Natal | 80mVp-p | BOmVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 2.85 – 3.6V | 4.75 – 5.5V | 10.8 – 13.2V | 13.5 – 16.5V | 22 – 27.6V | 42 – 54V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.3 | ±2.0% | ± 1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1800ms, 23ms/230VAC 4000ms, 30ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 80ms/230VAC 14ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 88 – 264VAC 125 – 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||||
FREQUENCY RANGE | 47 – 63Hz | ||||||
EFFICIENCY(Typ.) | 74.% | 179.% | 182.% | 184.% | I86% | I85% | |
AC CURRENT (Typ.) | 0.7A/115VAC 0.4A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 45A/230VAC | ||||||
LEAKAGE CURRENT | <2mA/ 240VAC | ||||||
PROTECTION | OVERLOAD | 110 -180% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 3.8 – 4.45V | I 5.75 – 6.75V | 1 13.8 – 16.2V | 1 17.25 – 20.25V | I 27.6 – 32.4V I | 55.2 – 64.8V | |
Protection type : Shut off o/p voltage, damping by zener diode | |||||||
ENVIRONMENT | WORKING TEMP. | -20 – +70t (Refer to ‘Derating Curve’) | |||||
WORKING HUMIDITY | 20 – 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 – +85t , 10 – 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%1°C (0 – 50°C) | ||||||
VIBRATION | 10 – 500Hz. 5G 10min./1cycle. period for 60min. each along X. Y, Z axes | ||||||
SAFETY & EMC (Note 6) |
SAFETY STANDARDS | UL62368-1, TUV BS EN1EN62368-1 , AS/NZS 62368.1, EAC TP TC 004, CCC 064943.1, BSMI CNS14336-1, BIS IS13252(Part1):201011EC 60950-1: 2005 approved | |||||
WITHSTAND VOLTAGE | UP-0/P:3KVAC UP-FG:2KVAC 0/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | 11P-0/P, UP-FG, O!P-FG:100M Ohms! 500VDC / 25°C/ 70% RH | ||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2.-3,G69254 class 6.GB17625.1, EAC TP TC 020, CNS13438 Class B | ||||||
EMC IMMUNITY | Compliance to 6S EN/EN61000-4-2,3,4,5,6,8,11, BS EN1EN55035, light industry level, EAC TP TC 020 | ||||||
OTHERS | MTBF | 3992.0K hrs min. Telcordia SR-332 (Bellcore) ; 663.3K firs min. MIL-HDBK-217F (25t ) | |||||
DIMENSION | 78*51’28mm (L*W•H) | ||||||
PACKING | 0.2Kg; 60pcs/13Kg10.46CUFT | ||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25-C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 rt F & 47 If F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high Me at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power sum is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.’ (as available on https://Awnv.meanwell.com//Upbad/PDF/EMIfitatement_en.pdf ) 7. The ambient temperature derating of 3.5-C/1000m with fanless models and of 5.C/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability Disdains. : For detailed information, please refer to https://wvmmeanwell.com/serviceDisciaimeraspx |
Mechanical Specification
Block Diagram
Derating Curve
Output Derating VS Input Voltage
Documents / Resources
![]() |
MEAN WELL RS-25 Series Single Output Switching Power Supply [pdf] Owner's Manual RS-25 Series Single Output Switching Power Supply, RS-25 Series, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |