30W Single Output LED Power Supply

PLN-30 series


MEAN WELL PLN-30-9 Single Output LED Power Supply

■ GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

User’s Manual

MEAN WELL PLN-30-9 Single Output LED Power Supply - QR Code

■ Features :
  • Universal AC input / Full range (up to 295VAC)
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit with adjustable OCP level
  • Fully isolated plastic case with P64 level
  • Built-in active PFC function
  • Pass LPS
  • Class II power unit, no FG
  • Class 2 power unit
  • 100% full load burn-in test
  • High reliability
  • Suitable for LED lighting and moving sign applications (Note.2)
  • Compliance to worldwide safety regulations for lighting
  • 2 years warranty

Class II Icon 2    MEAN WELL A - 1    MEAN WELL A - 2    MEAN WELL A - 3    MEAN WELL A - 4    MEAN WELL A - 4    MEAN WELL A - 5    MEAN WELL A - 6    MEAN WELL A - 7 (CCC Optional)    MEAN WELL - PFC    MEAN WELL - CCC    MEAN WELL - RU(for 48V only)    MEAN WELL - C RU US(except for 48V)    MEAN WELL A - 8BS EN/EN61347-1,-2-13    EAC Icon 3    Mean Well - CB    CE Icon    UKCA Icon

■ SPECIFICATION
MODEL PLN-30-9 PLN-30-12 PLN-30-15 PLN-30-20
OUTPUT DC VOLTAGE 9V 12V 15V 20V
CONSTANT CURRENT REGION 

Note.6

6.3 ~ 9V 8.4 ~ 12V 10.5 ~ 15V 14 ~ 20V
RATED CURRENT 3.3A 2.5A 2A 1.5A
CURRENT RANGE 0 ~ 3.3A 0 ~ 2.5A 0 ~ 2A 0 ~ 1.5A
RATED POWER 29.7W 30W 30W 30W
RIPPLE & NOISE (max.) 

Note.2

2.6Vp-p 2Vp-p 2.6Vp-p 2.6Vp-p
VOLTAGE ADJ. RANGE 

Note.5

-5% ~ 10%. Can be adjusted by internal potentiometer SVR1
CURRENT ADJ. RANGE 

Note.5

3% ~ -25%. Can be adjusted by internal potentiometer SVR2
VOLTAGE TOLERANCE 

Note.3

±10%
LINE REGULATION ±3.0%
LOAD REGULATION ±5.0%
SETUP TIME 500ms / 230VAC   3000ms / 115VAC at full load
INPUT VOLTAGE RANGE 

Note.4

90 ~ 295VAC   127 ~ 417VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to “Power Factor Characteristic” curve)
TOTAL HARMONIC DISTORTION THD< 20% when output loading≧75% at 115VAC/230VAC input and output loading≧80% at 277VAC input
EFFICIENCY (Typ.) 80% 82.5% 83.5% 84%
AC CURRENT (Typ.) 0.4A/115VAC   0.2A/230VAC   0.15A/277VAC
INRUSH CURRENT (Typ.) COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <0.5mA / 240VAC
PROTECTION OVER CURRENT 100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE 10 ~ 14V 14 ~ 17V 17 ~ 22V 23 ~ 26V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -30 ~ +50℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.06%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC SAFETY STANDARDS UL879, UL1310, CSA C22.2 No. 207-M89(except for 48V), TUV BS EN/EN61347-1, BS EN/EN61347-2-13, GB19510.1, GB19510.14, EAC TP TC 004, IP64 approved
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (pin≧25W), Class D (>70% load) ; BS EN/EN61000-3-3; GB/T 17743, GB17625.1,EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61547, light industry level, criteria B;EAC TP TC 020
OTHERS MTBF 4296.9K hrs min.   Telcordia SR-332 (Bellcore) ;   621.4Khrs min.   MIL-HDBK-217F (25℃)
DIMENSION 145*47*30mm (L*W*H)
PACKING 0.22Kg; 60pcs/14.2Kg/1.25CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated Joad and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
  5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
  6. Please refer to “DRIVING METHODS OF LED MODULE”. 
  7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMG performance will be affected by the complete installation, the final equipment manufacturers must re-quality EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf
  8. Direct connecting to LEDS is suggested, but is not suitable for using additional drivers. 
  9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power Supply can only be used behind a switch without permanently connected to the mains. 
  10. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan modes for operating altitude higher than 2000m(8500ft).
  11. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
  12. PLN-30-9 s used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be use for signaling products (including, but not limited to road-, railway.-, marineorair traffic-signaling-, traffic control or airfield lamps).

※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL PLN-30-24 PLN-30-27 PLN-30-36 PLN-30-48
OUTPUT DC VOLTAGE 24V 27V 36V 48V
CONSTANT CURRENT REGION 

Note.6

16.8 ~ 24V 18.9 ~ 27V 25.2 ~ 36V 33.6 ~ 48V
RATED CURRENT 1.25A 1.12A 0.84A 0.63A
CURRENT RANGE 0 ~ 1.25A 0 ~ 1.12A 0 ~ 0.84A 0 ~ 0.63A
RATED POWER 30W 30.24W 30.24W 30.24W
RIPPLE & NOISE (max.) 

Note.2

2.6Vp-p 2.3Vp-p 4.5Vp-p 3.7Vp-p
VOLTAGE ADJ. RANGE 

Note.5

-5% ~ 10%. Can be adjusted by internal potentiometer SVR1
CURRENT ADJ. RANGE 

Note.5

3% ~ -25%. Can be adjusted by internal potentiometer SVR2
VOLTAGE TOLERANCE 

Note.3

±10%
LINE REGULATION ±3.0%
LOAD REGULATION ±5.0%
SETUP TIME 500ms / 230VAC   3000ms / 115VAC at full load
INPUT VOLTAGE RANGE 

Note.4

90 ~ 295VAC   127 ~ 417VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to “Power Factor Characteristic” curve)
TOTAL HARMONIC DISTORTION THD< 20% when output loading≧75% at 115VAC/230VAC input and output loading≧80% at 277VAC input
EFFICIENCY (Typ.) 84% 84.5% 85% 85.5%
AC CURRENT (Typ.) 0.4A/115VAC   0.2A/230VAC   0.15A/277VAC
INRUSH CURRENT (Typ.) COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <0.5mA / 240VAC
PROTECTION OVER CURRENT 100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE 27 ~ 34V 31 ~ 35V 40 ~ 50V 53 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -30 ~ +50℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.06%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC SAFETY STANDARDS UL879, UL1310, CSA C22.2 No. 207-M89(except for 48V), TUV BS EN/EN61347-1, BS EN/EN61347-2-13, GB19510.1, GB19510.14, EAC TP TC 004, IP64 approved
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (pin≧25W), Class D (>70% load) ; BS EN/EN61000-3-3; GB/T 17743, GB17625.1,EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61547, light industry level, criteria B;EAC TP TC 020
OTHERS MTBF 4296.9K hrs min.   Telcordia SR-332 (Bellcore) ;   621.4Khrs min.   MIL-HDBK-217F (25℃)
DIMENSION 145*47*30mm (L*W*H)
PACKING 0.22Kg; 60pcs/14.2Kg/1.25CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated Joad and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
  5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
  6. Please refer to “DRIVING METHODS OF LED MODULE”. 
  7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMG performance will be affected by the complete installation, the final equipment manufacturers must re-quality EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf
  8. Direct connecting to LEDS is suggested, but is not suitable for using additional drivers. 
  9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power Supply can only be used behind a switch without permanently connected to the mains. 
  10. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan modes for operating altitude higher than 2000m(8500ft).
  11. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
  12. PLN-30-9 s used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be use for signaling products (including, but not limited to road-, railway.-, marineorair traffic-signaling-, traffic control or airfield lamps).

※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MEAN WELL logo1

■ Mechanical Specification

Case No.964A   Unit: mm

MEAN WELL PLN-30-9 Single Output LED Power Supply - a1

※ T case: Max. Case Temperature.

MEAN WELL PLN-30-9 Single Output LED Power Supply - a2

Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2 shown in the diagram.

MEAN WELL PLN-30-9 Single Output LED Power Supply - a3

SVR1 Output voltage adjustment
SVR2 Output current adjustment
■ Block Diagram

fosc : 39KHz(115VAC)
53KHz(230VAC)

MEAN WELL PLN-30-9 Single Output LED Power Supply - a4

■ Derating Curve

MEAN WELL PLN-30-9 Single Output LED Power Supply - b1

■ Static Characteristics

MEAN WELL PLN-30-9 Single Output LED Power Supply - b2

■ Power Factor Characteristic

Constant Current Mode

MEAN WELL PLN-30-9 Single Output LED Power Supply - b3

MEAN WELL PLN-30-9 Single Output LED Power Supply - b5 277Vac
MEAN WELL PLN-30-9 Single Output LED Power Supply - b6 230Vac
MEAN WELL PLN-30-9 Single Output LED Power Supply - b7 115Vac

■ EFFICIENCY vs LOAD (48V Model)

PLN-30 series possess superior working efficiency that up to 85.5% can be reached in field applications.

MEAN WELL PLN-30-9 Single Output LED Power Supply - b4

MEAN WELL PLN-30-9 Single Output LED Power Supply - b5 277Vac
MEAN WELL PLN-30-9 Single Output LED Power Supply - b6 230Vac
MEAN WELL PLN-30-9 Single Output LED Power Supply - b7 115Vac

■ DRIVING METHODS OF LED MODULE

This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.

MEAN WELL PLN-30-9 Single Output LED Power Supply - b8

  1. In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems.
    Should there be any compatibility issues, please contact MEAN WELL.
  2. Constant Current area
  3. Hiccup Protection

File Name:PLN-30-SPEC   2024-03-12

Documents / Resources

MEAN WELL PLN-30-9 Single Output LED Power Supply [pdf] Owner's Manual
PLN-30-9, PLN-30-12, PLN-30-15, PLN-30-20, PLN-30-24, PLN-30-27, PLN-30-36, PLN-30-48, PLN-30-9 Single Output LED Power Supply, PLN-30-9, Single Output LED Power Supply, Output LED Power Supply, LED Power Supply, Power Supply, Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *