LRS-200 Series Single Output Switching Power Supply
“
Specifications:
Model | DC Voltage | Rated Current | Rated Power | Ripple & Noise (max.) | Output Voltage Range | Setup, Rise Time | Hold Up Time (Typ.) | Voltage Range | Frequency Range | Efficiency (Typ.) | AC Current (Typ.) | Inrush Current (Typ.) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
LRS-200-3.3 | 3.3V | 40A | 132W | 150mVp-p | 10.2 ~ 13.8V | 1500ms, 50ms/230VAC | 16ms/230VAC | 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC | 47 ~ 63Hz | 83% | 4A/115VAC 2.2A/230VAC | COLD STAR 60A/115VAC 60A/230VAC |
Product Usage Instructions:
1. Installation:
Ensure the power supply is disconnected from the power source
before installation.
Mount the power supply securely in a well-ventilated area
following the manufacturer’s guidelines.
2. Connecting to Devices:
Use appropriate cables to connect the output of the power supply
to your devices.
Ensure correct polarity and voltage matching to prevent damage
to your devices.
3. Powering On:
Switch on the power supply and verify that the output voltage
matches your device requirements.
4. Maintenance:
Regularly check for any signs of overheating or unusual noises
from the power supply.
Keep the power supply clean and free from dust accumulation.
Frequently Asked Questions (FAQ):
Q: What is the maximum altitude for operating this power
supply?
A: The power supply can operate at altitudes up to 5000
meters.
Q: How do I select the appropriate model for my device?
A: Choose the model based on the required DC voltage and current
ratings of your device.
Q: What is the efficiency of the power supply?
A: The efficiency ranges from 83% to 90% depending on the
model.
“`
200W Single Output Switching Power Supply
LRS-200 series
User’s Manual
IS 13252
THOMAS SAMUEL
THOMAS SAMUEL
(Note 11)
EN61558-1 EN61558-2-16
Note 10
TP TC004
IEC62368-1 IEC61558-1 IEC61558-2-16
UL62368-1
(Note.9)
Operating altitude up to 5000 meters (Note.8)
Downloaded from Arrow.com.
File Name:LRS-200-SPEC 2025-04-07
200W Single Output Switching Power Supply
LRS-200 series
SPECIFICATION
MODEL
LRS-200-3.3 LRS-200-4.2 LRS-200-5 LRS-200-12 LRS-200-15 LRS-200-24 LRS-200-36 LRS-200-48
DC VOLTAGE
3.3V
4.2V
5V
12V
15V
24V
36V
48V
RATED CURRENT
40A
40A
40A
17A
14A
8.8A
5.9A
4.4A
CURRENT RANGE
0 ~ 40A 0 ~ 40A
0 ~ 40A
0 ~ 17A
0 ~ 14A
0 ~ 8.8A 0 ~ 5.9A 0 ~ 4.4A
RATED POWER
132W
168W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p
200W 150mVp-p
204W 150mVp-p
210W 150mVp-p
211.2W 150mVp-p
212.4W 200mVp-p
211.2W 200mVp-p
OUTPUT
VOLTAGE ADJ. RANGE 2.97 ~ 3.6V VOLTAGE TOLERANCE Note.3 ±3.0% LINE REGULATION Note.4 ±0.5% LOAD REGULATION Note.5 ±2.5%
3.6 ~ 4.4V ±4.0% ±0.5% ±2.5%
4.5 ~ 5.5V ±3.0% ±0.5% ±2.0%
10.2 ~ 13.8V 13.5 ~ 18V
±1.5%
±1.0%
±0.5%
±0.5%
±1.0%
±0.5%
21.6 ~ 28.8V 32.4 ~ 39.6V 43.2 ~ 52.8V
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME
1500ms, 50ms/230VAC 1500ms,50ms/115VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE
90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC)
FREQUENCY RANGE 47 ~ 63Hz
INPUT
EFFICIENCY (Typ.) AC CURRENT (Typ.)
83%
86%
87%
4A/115VAC 2.2A/230VAC
87.5%
88%
INRUSH CURRENT (Typ.) COLD STAR 60A/115VAC 60A/230VAC
89.5%
89.5%
90%
LEAKAGE CURRENT
<2mA / 240VAC
110 ~ 140% rated output power
OVER LOAD
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
PROTECTION OVER VOLTAGE
3.8 ~ 4.45V 4.6 ~ 5.4V 5.75 ~ 6.75V 13.8 ~ 16.2V 18 ~ 21V
28.8 ~ 33.6V 41.4 ~ 46.8V 55.2 ~ 64.8V
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
OVER TEMPERATURE
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
WORKING TEMP.
-25 ~ +70 (Refer to “Derating Curve”)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/ (0 ~ 50)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY : According to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY STANDARDS
IEC/UL 62368-1, BSMI CNS15598-1,EAC TP TC 004, KC62368-1(for LRS-200-12/24 only),GB 4943.1, BIS IS13252(Part1):2010/IEC 60950-1: 2005(NOTE 11) ,BS EN/EN61558-1, BS EN61558-2-16 Designed by AS/NZS 61558.1/2.16, AS/NZS 62368.1,BS EN/EN62368-1
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETY ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
EMC EMISSION
Compliance to BSMI CNS15936, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-200-12/24 only)
EMC IMMUNITY
Compliance to BS EN/EN55035, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-200-12/24 only)
MTBF
2346.6K hrs min. Telcordia SR-332 (Bellcore) ; 279.4Khrs min. MIL-HDBK-217F (25)
OTHERS DIMENSION
215*115*30mm (L*W*H)
PACKING
0.66Kg; 15pcs/10.9Kg/0.67CUFT
NOTE
11. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.
, https://www.meanwell.com/serviceDisclaimer.aspx
Downloaded from Arrow.com.
File Name:LRS-200-SPEC 2025-04-07
200W Single Output Switching Power Supply
LRS-200 series
Block Diagram
I/P
EMI FILTER
FG
Derating Curve
115/230V(SW)
RECTIFIERS
POWER SWITCHING
RECTIFIERS &
FILTER RECTIFIERS
& FILTER
O.L.P.
PWM CONTROL
O.T.P. O.V.P.
DETECTION CIRCUIT
Static Characteristics
fosc : 65KHz
+V -V
100
12~48V
80
3.3~5V
60 50 40
20
-25 -20 -10 0 10 20 30 40 50 60 70 (HORIZONTAL)
AMBIENT TEMPERATURE ()
100
90
180 ~ 264VAC
80
90 ~ 132VAC
70
60
50 40
90
95 100 105 110 115 120 125 132
180 190 200 210 220 230 240 250 264
INPUT VOLTAGE (VAC) 60Hz
LOAD (%) LOAD (%)
Downloaded from Arrow.com.
File Name:LRS-200-SPEC 2025-04-07
135
200W Single Output Switching Power Supply
Mechanical Specification
215
32.5
150
LRS-200 series
Case No. 207 Unit:mm Tolerance:±1
9.5
8
LED +V ADJ.
9 8 7 6 5 4 3 2 1
4-M4 L=3mm
15
32.5
150
2
12.8 6.9
6.5 6.5
16
32.5
50
115
12.5 30
4-M4(Both Sides) L=5mm
Terminal Pin No. Assignment :
Pin No. Assignment Pin No.
1
AC/L
4~6
2
AC/N
7~9
3
FG
Assignment DC OUTPUT -V DC OUTPUT +V
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Downloaded from Arrow.com.
File Name:LRS-200-SPEC 2025-04-07
Documents / Resources
![]() |
MEAN WELL LRS-200 Series Single Output Switching Power Supply [pdf] Installation Guide LRS-200-3.3, LRS-200-4.2, LRS-200-5, LRS-200-12, LRS-200-15, LRS-200-24, LRS-200-36, LRS-200-48, LRS-200 Series Single Output Switching Power Supply, LRS-200 Series, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply |