Features:
- Constant voltage design
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Over load / Over voltage
- Cooling by free air convection
- Fully encapsulated with IP67 level (Note.7)
- Fully isolated plastic case
- Class II power unit, no FG
- Class 2 power unit
- Pass LPS
- Suitable for LED-related fixtures or appliances (such as LED Decoration or Advertisement devices)(Note. 7)
- 100% full load burn-in test
- Low cost, high reliability
- 2 years warranty
http://www.meanwell.com.cn/Upload/PDF/LED_EN.pdf
SPECIFICATION
MODEL | LPV-60-5 | LPV-60-12 | LPV-60-15 | LPV-60-24 | LPV-60-36 | LPV-60-48 | |
OUTPUT |
DC VOLTAGE | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 8A | 5A | 4A | 2.5A | 1.67A | 1.25A | |
CURRENT RANGE | 0 ~ 8A | 0 ~ 5A | 0 ~ 4A | 0 ~ 2.5A | 0 ~ 1.67A | 0 ~ 1.25A | |
RATED POWER | 40W | 60W | 60W | 60W | 60W | 60W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±8.0% | ±5.0% | |||||
LINE REGULATION | ±1.0% | ||||||
LOAD REGULATION | ±6.0% | ±2.0% | |||||
SETUP, RISE TIME Note.6 | 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V) | ||||||
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load | ||||||
INPUT |
VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 76% | 83% | 83% | 86% | 86% | 86% | |
AC CURRENT (Typ.) | 1.2A/115VAC 1A/230VAC | ||||||
INRUSH CURRENT(Typ.) | COLD START 60A(twidth=525μs measured at 50% Speak) at 230VAC | ||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | ||||||
LEAKAGE CURRENT | 0.25mA / 240VAC | ||||||
PROTECTION |
OVERLOAD | 110 ~ 150% rated output power | |||||
Protection type: Hiccup mode, recovers automatically after the fault condition is removed | |||||||
OVERVOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | |
Protection type: Shut down o/p voltage, re-power on to recover | |||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, the period for 60min. each along X, Y, and Z axes | ||||||
SAFETY & EMC |
SAFETY STANDARDS |
UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(for LPV-60-12,LPV-60-24 only), EAC TP TC 004, IP67, IEC62368-1 , BS EN/EN62368-1 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020 | ||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 | ||||||
OTHERS |
MTBF | 5188.4K hrs min. Telcordia SR-332 (Bellcore); 732.1Khrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 162.5*42.5*32mm (L*W*H) | ||||||
PACKING | 0.4Kg; 32pcs/13.8Kg/0.63CUFT | ||||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25℃ of ambient temperature. |
Mechanical Specification
Recommend Mounting Direction
Block Diagram
Derating Curve
Static Characteristics
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx
Documents / Resources
![]() |
MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply [pdf] User Manual LPV-60 Series, 60W Single Output Switching Power Supply, LPV-60 Series 60W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply |
![]() |
MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply [pdf] User Guide LPV-60 Series, 60W Single Output Switching Power Supply, LPV-60 Series 60W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply, LPV-60-5, LPV-60-12, LPV-60-15, LPV-60-24, LPV-60-36, LPV-60-48 |
![]() |
MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply [pdf] User Manual LPV-60 Series, 60W Single Output Switching Power Supply, LPV-60 Series 60W Single Output Switching Power Supply |
![]() |
MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply [pdf] Owner's Manual LPV-60 Series 60W Single Output Switching Power Supply, LPV-60 Series, 60W Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply |
![]() |
MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply [pdf] Owner's Manual LPV-60 Series, LPV-60 Series 60W Single Output Switching Power Supply, 60W Single Output Switching Power Supply, Single Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |
![]() |
MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply [pdf] User Manual LPV-60-5, LPV-60-12, LPV-60-15, LPV-60-24, LPV-60-36, LPV-60-48, LPV-60 Series 60W Single Output Switching Power Supply, LPV-60 Series, 60W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |
![]() |
MEAN WELL LPV-60 Series 60W Single Output Switching Power Supply [pdf] Owner's Manual LPV-60-5, LPV-60-12, LPV-60-15, LPV-60-24, LPV-60-36, LPV-60-48, LPV-60 Series 60W Single Output Switching Power Supply, LPV-60 Series, 60W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |