User Manual for MEAN WELL models including: LPV-60 Series, 60W Single Output Switching Power Supply, LPV-60 Series 60W Single Output Switching Power Supply

数据手册下载

LPV-60-24 MEANWELL/台湾明纬LPV-60-24LED 驱动器 LPV-60-24型号/规格参数/最小包装/手册-百能云芯元器件


File Info : application/pdf, 2 Pages, 498.40KB

PDF preview unavailable. Download the PDF instead.

lpv-60-spec pdfjs
60W Single Output Switching Power Supply

LPV-60 series

   
SPECIFICATION





User's Manual





























IS 15885(Part 2/Sec13)

THOMAS SAMUEL

THOMAS SAMUEL

LPS IP67 

R-41027766
  

MODEL

LPV-60-5

LPV-60-12

LPV-60-15

LPV-60-24

LPV-60-36

LPV-60-48

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

36V

48V

RATED CURRENT

8A

5A

4A

2.5A

1.67A

1.25A

CURRENT RANGE

0 ~ 8A

0 ~ 5A

0 ~ 4A

0 ~ 2.5A

0 ~ 1.67A

0 ~ 1.25A

RATED POWER

40W

60W

60W

60W

60W

60W

RIPPLE & NOISE (max.) Note.2 80mVp-p

120mVp-p

120mVp-p

150mVp-p

150mVp-p

150mVp-p

VOLTAGE TOLERANCE Note.3 ±8.0%

±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±6.0%

±2.0%

SETUP, RISE TIME Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)

HOLD UP TIME (Typ.)

50ms/230VAC 16ms/115VAC at full load

VOLTAGE RANGE

Note.4 90 ~ 264VAC 127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

76%

83%

83%

86%

86%

86%

INPUT

AC CURRENT (Typ.) INRUSH CURRENT(Typ.)

1.2A/115VAC 1A/230VAC COLD START 60A(twidth=525s measured at 50% Ipeak) at 230VAC

MAX. No. of PSUs on 16A CIRCUIT BREAKER

3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

OVER LOAD PROTECTION
OVER VOLTAGE

110 ~ 150% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

5.75 ~ 6.75V

13.8 ~ 16.2V

17.25 ~ 20.25V

27.6 ~ 32.4V

Protection type : Shut down o/p voltage, re-power on to recover

41.4 ~ 48.6V

55.2 ~ 64.8V

WORKING TEMP.

-30 ~ +70 (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY STANDARDS

UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(for LPV-60-12,LPV-60-24 only), EAC TP TC 004, IP67, IEC62368-1 , BS EN/EN62368-1 approved

SAFETY & WITHSTAND VOLTAGE

I/P-O/P:3KVAC

EMC

ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH

EMC EMISSION

Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, light industry level, EAC TP TC 020

MTBF

5188.4K hrs min. Telcordia SR-332 (Bellcore) ; 732.1Khrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

162.5*42.5*32mm (L*W*H)

NOTE

PACKING

0.4Kg; 32pcs/13.8Kg/0.63CUFT

 



















https://www.meanwell.com/Upload/PDF/LED_EN.pdf 

. 

     ,    https://www.meanwell.com/serviceDisclaimer.aspx

Downloaded from Arrow.com.

File Name:LPV-60-SPEC 2022-03-24

60W Single Output Switching Power Supply
Mechanical Specification

AC/N(Blue) AC/L(Brown)

600±30 UL1015 18AWG

162.5 3.5

T case 3.6

81.5 3.6

3.5

T case: Max. Case Temperature.

LPV-60 series

Case No. 976A Unit:mm

600±30 UL1007 16AWG

+V(Red) -V(Black)

3.5 42.5 15 3.5
32

Recommend Mounting Direction

Block Diagram

EMI FILTER

I/P

&

RECTIFIERS

O.L.P.

POWER SWITCHING
PWM CONTROL

RECTIFIERS &
FILTER

DETECTION CIRCUIT
O.V.P.

fosc : 65KHz
+V -V

Derating Curve

Static Characteristics

100

230VAC

80

60

115VAC

40

20

-30 -15

0

15

30

40

50

60

70 (HORIZONTAL)

AMBIENT TEMPERATURE ()

100 90 80 70 60 50 40
90 100 125 135 145 155 165 175 180 200 230 264
INPUT VOLTAGE (V) 60Hz

LOAD (%) LOAD (%)

Downloaded from Arrow.com.

