MeanWell

MEAN WELL HEP-150 Switching Power Supply for Harsh Environment

MEAN-WELL-HEP-150-Switching-Power-Supply-for-Harsh-Environment

Features

  • Universal AC input/ Full range (up to 305VAC)
  • Built-in active PFC function
  • High efficiency up to 94%
  • Fanless design, cooling by free air convection
  • -55+70 C wide operating range
  • Aluminum case and filling with heat-conducted silicone
  • IP65 design, optional IP68 rated model available
  • Meet 6KV surge immunity level
  • Withstand 10G vibration test
  • Protections: Short circuit/Overload/ Over voltage /Over temperature
  • Operating altitude up to 5000 meters (Note.9)
  • 6 years warranty

Applications
Outdoor telecommunication equipment
Outdoor electronic signage and billboard
Petroleum plant or mine shaft facility

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

HEP-150 is a 150W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 94%, enabling HEP-150 perfectly work between -55C and +70C under free air convection.

Model EncodingMEAN-WELL-HEP-150-Switching-Power-Supply-for-Harsh-Environment-2

Specification

MODEL HEP-150-12 HEP-150-15 HEP-150-24 HEP-150-36 HEP-150-48 HEP-150-54
DC VOLTAGE 12V 15V 24V 36V 48V 54V  
RATED CURRENT 12.5A 10A 6.3A 4.2A 3.2A 2.8A  
RATED POWER 150W 150W 151.2W 151.2W 153.6W 151.2W  
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p  
VOLTAGE ADJ. RANGE Note.5 10.8 ~ 13.5V 13.5 ~ 17V 22 ~ 27V 33 ~ 40V 43 ~ 53V 49 ~ 58V  
CURRENT ADJ. RANGE Can be adjusted by internal potentiometer for A type only  
7.5 ~ 12.5A 6 ~ 10A 3.8 ~ 6.3A 2.5 ~ 4.2A 1.92 ~ 3.2A 1.68 ~ 2.8A  
VOLTAGE TOLERANCE Note.3 ±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%  
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%  
LOAD REGULATION ±2.0% ±1.5% ±0.5% ±0.5% ±0.5% ±0.5%  
SETUP, RISE TIME Note.7 1000ms,50ms/115VAC  500ms,50ms/230VAC at full load  
HOLD UP TIME (Typ.) 16ms at full load  230VAC /115VAC  
VOLTAGE RANGE Note.4 85~264VAC (277VAC operational)          120~370VDC(390VDC operational)  
FREQUENCY RANGE 47 ~ 63Hz  
POWER FACTOR (Typ.) PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load  
EFFICIENCY (Typ.) 91.5% 92% 93% 93.5% 94% 94%  
AC CURRENT (Typ.) 1.7A / 115VAC            0.75A / 230VAC            0.7A / 277VAC  
INRUSH CURRENT(Typ.) COLD START 65A at 230VAC  
LEAKAGE CURRENT <0.75mA / 277VAC  
OVERLOAD 105 ~ 125%  
Protection type : Constant current limiting, recovers automatically after fault condition is removed  
SHORT CIRCUIT Constant current limiting, recovers automatically after fault condition is removed  
 

OVER VOLTAGE

14 ~ 17V 18 ~ 21V 28 ~ 34V 41 ~ 46V 54 ~ 63V 59 ~ 65V  
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery  
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down  
WORKING TEMP. -55 ~ +70℃ (Refer to “Derating Curve”)  
WORKING HUMIDITY 20 ~ 95% RH non-condensing  
STORAGE TEMP., HUMIDITY -60 ~ +80℃, 10 ~ 95% RH non-condensing  
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 60℃)  
VIBRATION 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes  
SAFETY STANDARDS  Note.6,9 UL62368-1, IEC62368-1,IP65 (or IP68 for HEP-150 Blank type), EAC TP TC 004 approved ;

Design refer to BS EN/EN62368-1

 
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC   I/P-FG:2KVAC   O/P-FG:1.5KVAC  
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH  
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020  
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level (surge 6KV),

EAC TP TC 020

 
MTBF 1967.4K hrs min.        Telcordia SR-332 (Bellcore) ;  164.2Khrs min.         MIL-HDBK-217F (25℃)  
DIMENSION 228*68*38.8mm (L*W*H)  
PACKING 1.15Kg; 12pcs/14.8Kg/0.8CUFT  

Note:

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
  5. A type only.
  6. Safety and EMC design refer to BS ENEN60598-1, CNS15233, GB7000.1, FCC part18.
  7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
  8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-quality EMC Directive on the complete installation again.
  9. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
  10. The ambient temperature derating of 3.5 C /1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft).

X Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block DiagramMEAN-WELL-HEP-150-Switching-Power-Supply-for-Harsh-Environment-3

Derative CurveMEAN-WELL-HEP-150-Switching-Power-Supply-for-Harsh-Environment-4

Mechanical SpecificationMEAN-WELL-HEP-150-Switching-Power-Supply-for-Harsh-Environment-5

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

Documents / Resources

MEAN WELL HEP-150 Switching Power Supply for Harsh Environment [pdf] User Guide
HEP-150 Switching Power Supply Harsh Environment, HEP-150, Switching Power Supply Harsh Environment, Power Supply Harsh Environment, Harsh Environment, Environment

References

Leave a comment

Your email address will not be published. Required fields are marked *