MEAN WELL HEP-150 Switching Power Supply for Harsh Environment
Features
- Universal AC input/ Full range (up to 305VAC)
- Built-in active PFC function
- High efficiency up to 94%
- Fanless design, cooling by free air convection
- -55+70 C wide operating range
- Aluminum case and filling with heat-conducted silicone
- IP65 design, optional IP68 rated model available
- Meet 6KV surge immunity level
- Withstand 10G vibration test
- Protections: Short circuit/Overload/ Over voltage /Over temperature
- Operating altitude up to 5000 meters (Note.9)
- 6 years warranty
Applications
Outdoor telecommunication equipment
Outdoor electronic signage and billboard
Petroleum plant or mine shaft facility
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
HEP-150 is a 150W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 94%, enabling HEP-150 perfectly work between -55C and +70C under free air convection.
Model Encoding
Specification
MODEL | HEP-150-12 | HEP-150-15 | HEP-150-24 | HEP-150-36 | HEP-150-48 | HEP-150-54 | |||||||
DC VOLTAGE | 12V | 15V | 24V | 36V | 48V | 54V | |||||||
RATED CURRENT | 12.5A | 10A | 6.3A | 4.2A | 3.2A | 2.8A | |||||||
RATED POWER | 150W | 150W | 151.2W | 151.2W | 153.6W | 151.2W | |||||||
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | |||||||
VOLTAGE ADJ. RANGE Note.5 | 10.8 ~ 13.5V | 13.5 ~ 17V | 22 ~ 27V | 33 ~ 40V | 43 ~ 53V | 49 ~ 58V | |||||||
CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer for A type only | ||||||||||||
7.5 ~ 12.5A | 6 ~ 10A | 3.8 ~ 6.3A | 2.5 ~ 4.2A | 1.92 ~ 3.2A | 1.68 ~ 2.8A | ||||||||
VOLTAGE TOLERANCE Note.3 | ±2.5% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||||||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||||||
LOAD REGULATION | ±2.0% | ±1.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||||||
SETUP, RISE TIME Note.7 | 1000ms,50ms/115VAC 500ms,50ms/230VAC at full load | ||||||||||||
HOLD UP TIME (Typ.) | 16ms at full load 230VAC /115VAC | ||||||||||||
VOLTAGE RANGE Note.4 | 85~264VAC (277VAC operational) 120~370VDC(390VDC operational) | ||||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load | ||||||||||||
EFFICIENCY (Typ.) | 91.5% | 92% | 93% | 93.5% | 94% | 94% | |||||||
AC CURRENT (Typ.) | 1.7A / 115VAC 0.75A / 230VAC 0.7A / 277VAC | ||||||||||||
INRUSH CURRENT(Typ.) | COLD START 65A at 230VAC | ||||||||||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||||||||||
OVERLOAD | 105 ~ 125% | ||||||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||||||||||
SHORT CIRCUIT | Constant current limiting, recovers automatically after fault condition is removed | ||||||||||||
OVER VOLTAGE |
14 ~ 17V | 18 ~ 21V | 28 ~ 34V | 41 ~ 46V | 54 ~ 63V | 59 ~ 65V | |||||||
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery | |||||||||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||||||||
WORKING TEMP. | -55 ~ +70℃ (Refer to “Derating Curve”) | ||||||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||||||||||
STORAGE TEMP., HUMIDITY | -60 ~ +80℃, 10 ~ 95% RH non-condensing | ||||||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | ||||||||||||
VIBRATION | 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||||||||||
SAFETY STANDARDS Note.6,9 | UL62368-1, IEC62368-1,IP65 (or IP68 for HEP-150 Blank type), EAC TP TC 004 approved ;
Design refer to BS EN/EN62368-1 |
||||||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | ||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | ||||||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level (surge 6KV),
EAC TP TC 020 |
||||||||||||
MTBF | 1967.4K hrs min. Telcordia SR-332 (Bellcore) ; 164.2Khrs min. MIL-HDBK-217F (25℃) | ||||||||||||
DIMENSION | 228*68*38.8mm (L*W*H) | ||||||||||||
PACKING | 1.15Kg; 12pcs/14.8Kg/0.8CUFT |
Note:
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltages. Please check the static characteristics for more details.
- A type only.
- Safety and EMC design refer to BS ENEN60598-1, CNS15233, GB7000.1, FCC part18.
- Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-quality EMC Directive on the complete installation again.
- The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
- The ambient temperature derating of 3.5 C /1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft).
X Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derative Curve
Mechanical Specification
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Documents / Resources
![]() |
MEAN WELL HEP-150 Switching Power Supply for Harsh Environment [pdf] User Guide HEP-150 Switching Power Supply Harsh Environment, HEP-150, Switching Power Supply Harsh Environment, Power Supply Harsh Environment, Harsh Environment, Environment |