Features

  • Support 1+1 and N+1 redundancy system
  • 2 channels input and 1 output
  • Suitable for redundancy operation of 12V/24V/48V system
  • Output current up to 20A
  • Cooling by free air convection
  • -40~+80°C ultra-wide operating temperature (>+60°C derating)
  • 32mm slim width
  • Built-in 2 channels DC OK signal and alarm relay contact
  • Installed on DIN Rail TS35/7.5 or 15
  • 3 years warranty

Applications

  • Industrial control system
  • Semiconductor fabrication equipment
  • Factory automation
  • Electro-mechanical apparatus

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

The DRDN20 series is a 20A redundancy module that can be used with a power supply to improve overall system operation reliability. Product key features include: 12V/24V/48V input voltage for selection, support N+1 and 1+1 redundancy systems, built-in two rails DC input contacts and single output. The MOSFET technology implemented can reduce heat loss and reduce the voltage difference between the input and output voltages, built-in 2 channels DC OK relay contacts for monitoring output status, ultra-wide operating temperature of -40 to +80°C and narrow width (32mm.

Model Encoding
Installation Instruction

SPECIFICATION

 MODEL DRDN20-
=12V, 24V, 48V
     INPUT NUMBER OF INPUT 2 Channels
DC NORMAL VOLTAGE 12Vdc 24Vdc 48Vdc
DC VOLTAGE RANGE 9~14Vdc 19~29Vdc 36~60Vdc
RATED CURRENT 0~20A per input         Continuous
VOLTAGE DROP (Vin-Vout)   (max.) 0.25V
PEAK CURRENT 0~30A per input          5Sec.
EFFICIENCY (Typ.) 98%
INPUT REVERSE CURRENT (max.) 1mA
INPUT REVERSE VOLTAGE (max.) 40Vdc 40Vdc 65Vdc
  OUTPUT RATED CURRENT 0~20A, Continuous
PEAK CURRENT (max.) 30A, 5Sec.
CAPACITANCE(Typ.) 320uF
STANDBY POWER LOSSES(Typ.) 1.5W
 PROTECTION OVERLOAD <30A,5Sec. No damage
SHORT CIRCUIT <30A,5Sec. No damage
   FUNCTION REDUNDANCY For 1+1 redundancy ,and support N+1 redundancy
BOTH INPUTS VOLTAGE ALARM <8.5V or >14.7V (±5%) <18V or >31V (±5%) <34.2V or >63V (±5%)
RELAY 30Vdc/1A resistive load
LED STATUS DISPLAY Green LED OK
     ENVIRONMENT COOLING Free air convection
WORKING TEMP.                         Note.2 -40 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 5 ~ 95% RH non-condensing
STORAGE TEMP. -40 ~ +85℃
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 60℃)
VIBRATION Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373
OPERATING ALTITUDE            Note.3 5000 meters/OVC II
         SAFETY & EMC(Note.4) SAFETY STANDARDS IEC62368-1, UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE IP/OP – Chassis : 0.5KVac ; IP/OP- Relay : 0.5KVac ; Relay – Chassis : 0.5KVac
ISOLATION RESISTANCE IP/OP – Chassis, IP/OP- Relay, Relay – Chassis:>100M Ohms / 500Vdc / 25℃/ 70% RH
   EMC EMISSION Parameter Standard Test Level / Note
Conducted BS EN/EN55032(CISPR32) Class B
Radiated BS EN/EN55032(CISPR32) Class B
Voltage Flicker —– —–
Harmonic Current —– —–
       EMC IMMUNITY BS EN/EN55035, BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter Standard Test Level / Note
ESD BS EN/EN61000-4-2 Level 4, 15KV air ; Level 3, 8KV contact; criteria A
Radiated BS EN/EN61000-4-3 Level 3, 10V/m ; criteria A
EFT / Burst BS EN/EN61000-4-4 Level 3, 2KV ; criteria A
Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-Chassis ;criteria A
Conducted BS EN/EN61000-4-6 Level 3, 10V ; criteria A
Magnetic Field BS EN/EN61000-4-8 Level 4, 30A/m ; criteria A
 OTHERS MTBF 1836.0K hrs min.     Telcordia SR-332 (Bellcore) ;   482.1K hrs min.     MIL-HDBK-217F (25℃)
DIMENSION 32*125.2*102mm (W*H*D)
PACKING 0.35Kg;28psc/10.8Kg/1.24CUFT
    NOTE 1. All parameters NOT specially mentioned are measured at normal input (12V/24V/48V), rated load and 25℃ of ambient temperature.2. Derating may be needed over high ambient temperature. Please check the derating curve for more details.3. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.”(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram
Installation Instruction

DC OK Relay Contact

Contact Ratings (max.) 30V/1A resistive load
Contact Close(DC OK) PSU turns on
Contact Open(DC Fail) PSU turns off / over or under input voltage
Derating Curve
Installation Instruction
Output Derating VS Input Voltage
Installation Instruction
Typical Application Notes
1+1 Redundancy:
Using 1 more PSU as the redundant unit
Installation Instruction
1+N Redundancy:
Using more PSUs as the redundant units to increase the reliability
Installation Instruction
 Single Use:

Connecting only one PSU to one DRDN20 to reduce the stress of the and hence increase the reliability
Installation Instruction

Mechanical Specification

  • Side View
    Installation Instruction
  • Top View
    Installation Instruction
  • Front View
    Installation Instruction
  • Side View
    Installation Instruction
  • Bottom View
    Installation Instruction
Terminal Pin No. Assignment (TB3 
Pin No. Assignment
1,2 Alarm1 DC OK
3,4 Alarm2 DC OK
5 FG
6,7 DC output  +Vout
8 DC output  -Vout

Installation Instruction

ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
(For reference only. Not included with unit.)
Back View
This series fits DIN rail TS35/7.5 or TS35/15.
For installation details, please refer to the Instruction manual
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
icons icons
Company Logo

Documents / Resources

MEAN WELL DRDN20 20A DIN Rail Type Redundancy Module [pdf] Owner's Manual
DRDN20, DRDN20 20A DIN Rail Type Redundancy Module, 20A DIN Rail Type Redundancy Module, DIN Rail Type Redundancy Module, Type Redundancy Module, Redundancy Module, Module

References

Leave a comment

Your email address will not be published. Required fields are marked *