MEAN WELL XLC-60-MA 60W Multiple Stage Constant Power Constant Voltage LED Driver
Product Usage Instructions
Installation Guidelines
The device has an integrated antenna for easy integration. Follow these guidelines when mounting the device:
- Keep the device away from vertical metal structures.
- If mounting on a metal plate, ensure the antenna is not obscured and there is a cutout under it for RF signal transmission.
- Environmental factors and installation positioning may affect communication range, necessitating on-site adjustments and testing.
Resetting AC ON/OFF Process
If there is a malfunction in the ‘AC ON/OFF process’, reset by following these methods:
- AC ON time exceeds 25 seconds.
- AC ON times for 2-5 seconds and repeat twice.
Additional Information
- For detailed installation instructions, refer to the Installation Manual.
60W Multiple-Stage Constant Power/Constant Voltage LED Driver
Features
- Constant power mode output with multiple stage selectable by DIP switch (H-type)
- Constant voltage mode output(12/24/48V)
- Plastic housing with class II and PFC design
- Flicker free, complying with CE Erp directive
- Standby power consumption <O.5W
- Meet emergency lighting (EL) application
- Minimum dimming level 0.1% (12/24/48V)
- Minimum dimming level 0.5% (H-type)
- Matter over thread, Matter 1.3 specification
- 5 years warranty
Applications
- Recessed Light
- Down Light
- Panel Light
- Commercial Lighting
- Decorative Lighting
- LED strip lighting
- Matter wireless Lighting
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx
Description
XLC-60-MA series is a 60W with constant power and constant voltage output LED driver . It can operate from AC and output current ranging between 900 mA to 1700 mA selectable by DIP switch. Thanks to high efficiency up to 90%, it is able to operate for -250 case temperature under free air convection. XLC-60-MA series is designed based on latest safety regulations with matter wireless dimming.lt provides more flexibility for LED Lighting application.
Model Encoding
Type | Function | Note |
MA |
H type output current selectable by DIP switch, without strain-relief(Built-in type) |
In stock |
12, 24, 48V Constant voltage output, without strain-relief(Built-in type) | ||
MAS |
H type output current selectable by DIP switch, with strain-relief(Independent type) |
In stock |
12, 24, 48V Constant voltage output, with strain-relief(Independent type) |
SPECIFICATION
MODEL | XLC-60 -12-MA | XLC-60-24-MA | XLC-60-48-MA | ||||
OUTPUT |
DC VOLTAGE | 12V | 24V | 48V | |||
DEFAULT CURRENT | 5A | 2.5A | 1.25A | ||||
RATED POWER | Note.2 | 60W | 60W | 60W | |||
SETUP,RISE TIME | Note.3 | 2500ms,180ms/230VAC ,2500ms,180ms/115VAC | |||||
INPUT |
VOLTAGE RANGE | 100~305VAC 155~400VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR | PF≥0.95/115VAC, PF≥0.95/230VAC, PF≥0.9/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section) |
||||||
TOTAL HARMONIC DISTORTION | THD< 20%(@load ≥60%/230VAC; @load ≥75%/277VAC); THD<10%@load 100%/230VAC (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) | ||||||
EFFICIENCY(Typ.) | 86% | 87% | 88% | ||||
AC CURRENT | 0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC | ||||||
INRUSH CURRENT | COLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||||
MAX. NO. of PSUs on 16A CIRCUIT BREAKER | 25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC | ||||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||||
STANDBY POWER CONSUMPTION | Note.4 | Standby power consumption<0.5W (Dimming OFF) | |||||
PROTECTION |
OVERLOAD |
105~200% rated output power | |||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed. | |||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE |
14~17V | 26~35V | 52~63V | ||||
Shut down output voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Shut down output voltage, recovers automatically after fault condition is removed | ||||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | |||||
MAX. CASE TEMP. | Tcase=90℃ | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP.,HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC |
SAFETY STANDARDS |
CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations (DC input 176-280VDC); BS EN/EN62384, GB/T 19510.1, GB/T 19510.213, EAC TP TC 004 approved;
Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13 |
|||||
WITHSTAND VOLTAGE | I/P-O/P: 3.75KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P: >100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION |
Parameter | Standard | Test Level/Note | ||||
Conducted | BS EN/EN55015(CISPR15) ,GB/T 17743 | —– | |||||
Radiated | BS EN/EN55015(CISPR15) ,GB/T 17743 | —– | |||||
Harmonic Current | BS EN/EN61000-3-2 , GB17625.1 | Class C @load≥60% | |||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||||
EMC IMMUNITY |
BS EN/EN61547 | ||||||
Parameter | Standard | Test Level/Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||||
Radiated | BS EN/EN61000-4-3 | Level 2 | |||||
EFT/Burst | BS EN/EN61000-4-4 | Level 2 | |||||
Surge | BS EN/EN61000-4-5 | Level 3, 1KV/Line-Line | |||||
Conducted | BS EN/EN61000-4-6 | Level 2 | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 2 | |||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | 70% residual voltage for 10
period, 0% residual voltage for 0.5 periods |
|||||
OTHERS |
MATTER STANDARD | Matter 1.3 Specification | |||||
FLICKER | Note.7 | PstLM ≤ 1, SVM ≤ 0.4 | |||||
MTBF | 4130.5K hrs min. Telcordia SR-332 (Bellcore) | 317.7Khrs min. | MIL-HDBK-217F (25℃) | ||||
DIMENSION | 176*45*32mm , 136*45*32mm (L*W*H) | ||||||
PACKING | 0.32Kg; 40pcs/13.8Kg/0.48CUFT(for Blank type); 0.39Kg; 40pcs/16.6Kg/0.61CUFT(for S-type); | ||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details. 3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. 4. Standby power consumption is measured at 230VAC. 5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). 7. Flicker is measured at full load with the light source provided by MEAN WELL. 8. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. 9. This series meets the typical life expectancy of 50000 hours of operation when Tcase, particularly tc point(or TMP, per DLC), is about 75℃ or less. 10. For more information, please contact with MEAN WELL sales. ※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
MODEL | XLC-60-H-MA | ||||||
OUTPUT |
OPEN CIRCUIT VOLTAGE Note.2 | 60V | |||||
DEFAULT CURRENT | 1400mA | ||||||
CURRENT ADJ. RANGE (BY DIP SWITCH) |
0.9~1.7A |
||||||
CONSTANT CURRENT REGION | 9~54V | ||||||
RATED POWER | Note.4 | 60W | |||||
CURRENT RIPPLE | Note.5 | <4% | |||||
CURRENT TOLERANCE | ±5% | ||||||
DIMMING RANGE | 0~100% | ||||||
SETUP, RISE TIME | Note.6 | 2500ms,100ms/230VAC ,2500ms,100ms/115VAC | |||||
INPUT |
VOLTAGE RANGE | 100~305VAC 155~400VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR |
PF≥0.95/115VAC, PF≥0.95/230VAC,PF≥0.9/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section) |
||||||
TOTAL HARMONIC DISTORTION | THD< 20%(@load ≥60%/230VAC; @load ≥75%/277VAC); THD<10%@load 100%/230VAC (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) | ||||||
EFFICIENCY(Typ.) | Note.7 | 90% | |||||
AC CURRENT | 0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC | ||||||
INRUSH CURRENT | COLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||||
MAX. NO. of PSUs on 16A CIRCUIT BREAKER |
25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC |
||||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||||
STANDBY POWER CONSUMPTION | Note.9 | Standby power consumption<0.5W (Dimming off) | |||||
PROTECTION |
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||
OVER TEMPERATURE | Stage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed. | ||||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | |||||
MAX. CASE TEMP. | Tcase=90℃ | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC |
SAFETY STANDARDS |
CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations (DC input 176- 280VDC); BS EN/EN62384 , GB/T 19510.1, GB/T 19510.213, EAC TP TC 004 approved;
Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13 |
|||||
WITHSTAND VOLTAGE | I/P-O/P: 3.75KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P: >100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION |
Parameter | Standard | Test Level/Note | ||||
Conducted | BS EN/EN55015(CISPR15) ,GB/T 17743 | —– | |||||
Radiated | BS EN/EN55015(CISPR15) ,GB/T 17743 | —– | |||||
Harmonic Current | BS EN/EN61000-3-2 , GB17625.1 | Class C @load≥60% | |||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||||
EMC IMMUNITY |
BS EN/EN61547 | ||||||
Parameter | Standard | Test Level/Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||||
Radiated | BS EN/EN61000-4-3 | Level 2 | |||||
EFT/Burst | BS EN/EN61000-4-4 | Level 2 | |||||
Surge | BS EN/EN61000-4-5 | Level 3, 1KV/Line-Line | |||||
Conducted | BS EN/EN61000-4-6 | Level 2 | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 2 | |||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | 70% residual voltage for 10
period, 0% residual voltage for 0.5 periods |
|||||
OTHERS |
MATTER STANDARD | Matter 1.3 Specification | |||||
FLICKER | Note.10 | PstLM ≤ 1, SVM ≤ 0.4 | |||||
MTBF | 4130.5K hrs min. Telcordia SR-332 (Bellcore) | 317.7Khrs min. | MIL-HDBK-217F (25℃) | ||||
DIMENSION | 176*45*32mm , 136*45*32mm (L*W*H) | ||||||
PACKING | 0.32Kg; 40pcs/13.8Kg/0.48CUFT(for blank type); 0.39Kg; 40pcs/16.6Kg/0.61CUFT(for S-type); | ||||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. Output hiccups under no-load condition. 3. Please refer to “DRIVER METHODS OF LED MODULE”. 4. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details. 5. Current ripple is measured 50%~100% of maximum voltage under rated power delivery. 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. 7. Efficiency is measured at 1050mA/54V output set by DIP switch. 8. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. 9. Standby power consumption is measured at 230VAC. 10. Flicker is measured at full load with the light source provided by MEAN WELL. 11. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 12. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m (6500ft). 13. This series meets the typical life expectancy of 50000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less. 14. For more information, please contact with MEAN WELL sales. ※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
BLOCK DIAGRAM
DRIVING METHODS OF LED MODULE
Operating Area
XLC-60-H-MA
CONSTANT POWER TABLE
XLC-60-H-MA is a multiple-stage constant power driver, selection of output current through DIP switch setting is exhibited below.
Vo | Io DIP S.W | 1 | 2 | 3 |
9~54V | 900mA | —- | —- | —- |
9~54V | 1050mA | —- | —- | ON |
9~50V | 1200mA | —- | ON | —- |
9~46V | 1300mA | —- | ON | ON |
9~43V | 1400mA(default) | ON | —- | —- |
9~40V | 1500mA | ON | —- | ON |
9~38V | 1600mA | ON | ON | —- |
9~36V | 1700mA | ON | ON | ON |
Note: The operating voltage range which show on this table is recommend to use.
PWM OUTPUT DIMMING PRINCIPLE
- For 12V124V148V PWM style output dimming
- Dimming is achieved by varying the duty cycle of the output current.
OUTPUT LOAD vs TEMPERATURE
- STATIC CHARACTERISTIC
- LIFE TIME
TOTAL HARMONIC DISTORTION (THD)
- XLC-60-H-MA Modie, Tcase at 750C
POWER FACTOR PF CHARACTERISTIC
XLC-60-H-MA Modie, Tcase at 750C
A EFFICIENCY vs LOAD
- XLC-60-H-MA series possess superior working efficiency that up to 90% can be reached in field applications.
- XLC-60-H-MA Modie, Tcase at 750C
MECHANICAL SPECIFICATION
XLC-60-MA series Built-in Type
XLC-60-MAS series Independent Type
LED indicator
Flash slowly | Bluetooth Broadcast running |
Flash quickly | Factory Reset running. |
Constantly ON | Matter wireless connected |
Constantly OFF | Matter wireless disconnected and Bluetooth Broadcast OFF |
FACTORY RESET
By RESET BUTTON
Press and hold the reset button for 10 seconds. When the LED indicator flashes quickly, release the button. The factory reset will then be completed.
By AC ON/OFF
To perform a factory reset through AC ON/OFF, the following process must be strictly followed. If the AC ON/OFF process is correct, the output light will flash for 15 seconds. When the flashing stop, it means the factory reset is completed. This operation is consistent with the factory reset effect performed by long-pressing the reset button.
AC ON/OFF process to execute factory reset:
Phase | Duration | AC status |
1 | 10-15s | ON |
2 | >30s | OFF |
3 | 2-5s | ON |
4 | >30s | OFF |
5 | 10-15s | ON |
6 | >30s | OFF |
7 | 2-5s | ON |
8 | >30s | OFF |
9 | 2-5s | ON |
10 | >30s | OFF |
11 | >25s | ON(should wait until output light stop flashing) |
If there is a malfunction in the ‘AC ON/OFF process’, the process can be reset by the following method, starting from stage 1 again.
- Method 1 : AC ON time exceeds 25 seconds
- Method 2: AC ON times for 2-5s and twice
PLACEMENT
Matter device has an integrated antenna for easy integration. In order to maximize the range in every direction, some design guidelines should be taken into consideration when mounting the device.
The antenna positions of the device are shown in the figure below:
- Keep the device as far away as possible from vertical metal structures.
- When the device is mounted on a metal plate, the antenna should not be obscured, and there needs to be a cutout under the antenna to ensure that the RF signal can be transmitted.
- The device’s communication range may be influenced by environmental factors and installation positioning, necessitating on-site adjustments and testing.
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
FAQs
Q: How do I select the output voltage?
A: The output voltage (12/24/48V) can be selected by using the DIP switch on the device.
Q: What should I do if the device malfunctions during the AC ON/OFF process?
A: Follow the reset methods mentioned in the user manual to reset the AC ON/OFF process.
Q: How can I maximize the communication range of the device?
A: Follow the placement guidelines provided in the manual to ensure optimal communication range.
Documents / Resources
![]() |
MEAN WELL XLC-60-MA 60W Multiple Stage Constant Power Constant Voltage LED Driver [pdf] User Guide XLC-60-MAS, XLC-60-MA, XLC-60-MA 60W Multiple Stage Constant Power Constant Voltage LED Driver, XLC-60-MA, 60W Multiple Stage Constant Power Constant Voltage LED Driver, Constant Power Constant Voltage LED Driver, Constant Voltage LED Driver, Voltage LED Driver, LED Driver, Driver |