MEAN WELL XLC-60-MA 60W Multiple Stage Constant Power Constant Voltage LED Driver

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-product

Product Usage Instructions

Installation Guidelines
The device has an integrated antenna for easy integration. Follow these guidelines when mounting the device:

  • Keep the device away from vertical metal structures.
  • If mounting on a metal plate, ensure the antenna is not obscured and there is a cutout under it for RF signal transmission.
  • Environmental factors and installation positioning may affect communication range, necessitating on-site adjustments and testing.

Resetting AC ON/OFF Process
If there is a malfunction in the ‘AC ON/OFF process’, reset by following these methods:

  1. AC ON time exceeds 25 seconds.
  2. AC ON times for 2-5 seconds and repeat twice.

Additional Information

  • For detailed installation instructions, refer to the Installation Manual.

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (1)

60W Multiple-Stage Constant Power/Constant Voltage LED Driver

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (2)

Features

  • Constant power mode output with multiple stage selectable by DIP switch (H-type)
  • Constant voltage mode output(12/24/48V)
  • Plastic housing with class II and PFC design
  • Flicker free, complying with CE Erp directive
  • Standby power consumption <O.5W
  • Meet emergency lighting (EL) application
  • Minimum dimming level 0.1% (12/24/48V)
  • Minimum dimming level 0.5% (H-type)
  • Matter over thread, Matter 1.3 specification
  • 5 years warranty

Applications

  • Recessed Light
  • Down Light
  • Panel Light
  • Commercial Lighting
  • Decorative Lighting
  • LED strip lighting
  • Matter wireless Lighting

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx

Description
XLC-60-MA series is a 60W with constant power and constant voltage output LED driver . It can operate from AC and output current ranging between 900 mA to 1700 mA selectable by DIP switch. Thanks to high efficiency up to 90%, it is able to operate for -250 case temperature under free air convection. XLC-60-MA series is designed based on latest safety regulations with matter wireless dimming.lt provides more flexibility for LED Lighting application.

Model Encoding

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- 17

Type Function Note
 

MA

H type output current selectable by DIP switch, without strain-relief(Built-in type)  

In stock

12, 24, 48V Constant voltage output, without strain-relief(Built-in type)
 

MAS

H type output current selectable by DIP switch, with strain-relief(Independent type)  

In stock

12, 24, 48V Constant voltage output, with strain-relief(Independent type)

SPECIFICATION

MODEL XLC-60 -12-MA XLC-60-24-MA XLC-60-48-MA
 

 

OUTPUT

DC VOLTAGE 12V 24V 48V
DEFAULT CURRENT 5A 2.5A 1.25A
RATED POWER Note.2 60W 60W 60W
SETUP,RISE TIME Note.3 2500ms,180ms/230VAC ,2500ms,180ms/115VAC
 

 

 

 

 

 

 

 

INPUT

VOLTAGE RANGE 100~305VAC             155~400VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF≥0.95/115VAC, PF≥0.95/230VAC, PF≥0.9/277VAC@full load

(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)

TOTAL HARMONIC DISTORTION THD< 20%(@load ≥60%/230VAC; @load ≥75%/277VAC); THD<10%@load 100%/230VAC (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY(Typ.) 86% 87% 88%
AC CURRENT 0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC
INRUSH CURRENT COLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER 25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <0.75mA / 277VAC
STANDBY POWER CONSUMPTION Note.4 Standby power consumption<0.5W (Dimming OFF)
 

 

 

PROTECTION

 

OVERLOAD

105~200% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed
 

OVER VOLTAGE

14~17V 26~35V 52~63V
Shut down output voltage, re-power on to recover
OVER TEMPERATURE Shut down output voltage, recovers automatically after fault condition is removed
 

 

 

ENVIRONMENT

WORKING TEMP. Tcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP. Tcase=90℃
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP.,HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

 

 

 

 

 

 

 

 

 

 

SAFETY

& EMC

 

SAFETY STANDARDS

CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations (DC input 176-280VDC); BS EN/EN62384, GB/T 19510.1, GB/T 19510.213, EAC TP TC 004 approved;

Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13

WITHSTAND VOLTAGE I/P-O/P: 3.75KVAC
ISOLATION RESISTANCE I/P-O/P: >100M Ohms / 500VDC / 25℃/ 70% RH
 

 

 

EMC EMISSION

Parameter Standard Test Level/Note
Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 —–
Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 —–
Harmonic Current BS EN/EN61000-3-2 , GB17625.1 Class C @load≥60%
Voltage Flicker BS EN/EN61000-3-3 —–
 

 

 

 

 

 

 

EMC IMMUNITY

BS EN/EN61547
Parameter Standard Test Level/Note
ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated BS EN/EN61000-4-3 Level 2
EFT/Burst BS EN/EN61000-4-4 Level 2
Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line
Conducted BS EN/EN61000-4-6 Level 2
Magnetic Field BS EN/EN61000-4-8 Level 2
Voltage Dips and Interruptions BS EN/EN61000-4-11 70% residual voltage for 10

period, 0% residual voltage for 0.5 periods

 

 

 

OTHERS

MATTER STANDARD Matter 1.3 Specification
FLICKER Note.7 PstLM ≤ 1, SVM ≤ 0.4
MTBF 4130.5K hrs min. Telcordia SR-332 (Bellcore) 317.7Khrs min. MIL-HDBK-217F (25℃)  
DIMENSION 176*45*32mm , 136*45*32mm (L*W*H)
PACKING 0.32Kg; 40pcs/13.8Kg/0.48CUFT(for Blank type);              0.39Kg; 40pcs/16.6Kg/0.61CUFT(for S-type);
NOTE 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.

2.  De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

3.  Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.

4.  Standby power consumption is measured at 230VAC.

5.  The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

6.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

7.  Flicker is measured at full load with the light source provided by MEAN WELL.

8.  For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.

9.  This series meets the typical life expectancy of 50000 hours of operation when Tcase, particularly tc point(or TMP, per DLC), is about 75℃ or less.

10.  For more information, please contact with MEAN WELL sales.

※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MODEL XLC-60-H-MA
 

 

 

 

 

 

OUTPUT

OPEN CIRCUIT VOLTAGE Note.2 60V
DEFAULT CURRENT 1400mA
CURRENT ADJ. RANGE (BY DIP SWITCH)  

0.9~1.7A

CONSTANT CURRENT REGION 9~54V
RATED POWER Note.4 60W
CURRENT RIPPLE Note.5 <4%
CURRENT TOLERANCE ±5%
DIMMING RANGE 0~100%
SETUP, RISE TIME Note.6 2500ms,100ms/230VAC ,2500ms,100ms/115VAC
 

 

 

 

 

 

 

 

INPUT

VOLTAGE RANGE 100~305VAC            155~400VDC
FREQUENCY RANGE 47 ~ 63Hz
 

POWER FACTOR

PF≥0.95/115VAC, PF≥0.95/230VAC,PF≥0.9/277VAC@full load

(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)

TOTAL HARMONIC DISTORTION THD< 20%(@load ≥60%/230VAC; @load ≥75%/277VAC); THD<10%@load 100%/230VAC (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY(Typ.) Note.7 90%
AC CURRENT 0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC
INRUSH CURRENT COLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER  

25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC

LEAKAGE CURRENT <0.75mA / 277VAC
STANDBY POWER CONSUMPTION Note.9 Standby power consumption<0.5W (Dimming off)
 

PROTECTION

SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATURE Stage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed.
 

 

 

ENVIRONMENT

WORKING TEMP. Tcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP. Tcase=90℃
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

 

 

 

 

 

 

 

 

SAFETY

& EMC

 

SAFETY STANDARDS

CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations (DC input 176- 280VDC); BS EN/EN62384 , GB/T 19510.1, GB/T 19510.213, EAC TP TC 004 approved;

Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13

WITHSTAND VOLTAGE I/P-O/P: 3.75KVAC
ISOLATION RESISTANCE I/P-O/P: >100M Ohms / 500VDC / 25℃/ 70% RH
 

 

EMC EMISSION

Parameter Standard Test Level/Note
Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 —–
Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 —–
Harmonic Current BS EN/EN61000-3-2 , GB17625.1 Class C @load≥60%
Voltage Flicker BS EN/EN61000-3-3 —–
 

 

 

 

 

EMC IMMUNITY

BS EN/EN61547
Parameter Standard Test Level/Note
ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated BS EN/EN61000-4-3 Level 2
EFT/Burst BS EN/EN61000-4-4 Level 2
Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line
Conducted BS EN/EN61000-4-6 Level 2
Magnetic Field BS EN/EN61000-4-8 Level 2
Voltage Dips and Interruptions BS EN/EN61000-4-11 70% residual voltage for 10

period, 0% residual voltage for 0.5 periods

 

 

OTHERS

MATTER STANDARD Matter 1.3 Specification
FLICKER Note.10 PstLM ≤ 1, SVM ≤ 0.4
MTBF 4130.5K hrs min. Telcordia SR-332 (Bellcore) 317.7Khrs min. MIL-HDBK-217F (25℃)  
DIMENSION 176*45*32mm , 136*45*32mm (L*W*H)
PACKING 0.32Kg; 40pcs/13.8Kg/0.48CUFT(for blank type);              0.39Kg; 40pcs/16.6Kg/0.61CUFT(for S-type);
 

NOTE

1.  All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.

2.  Output hiccups under no-load condition.

3.  Please refer to “DRIVER METHODS OF LED MODULE”.

4.  De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

5.  Current ripple is measured 50%~100% of maximum voltage under rated power delivery.

6.  Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.

7.  Efficiency is measured at 1050mA/54V output set by DIP switch.

8.  For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.

9.  Standby power consumption is measured at 230VAC.

10.  Flicker is measured at full load with the light source provided by MEAN WELL.

11. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

12.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m (6500ft).

13.  This series meets the typical life expectancy of 50000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.

14.  For more information, please contact with MEAN WELL sales.

※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

BLOCK DIAGRAM

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (3)

DRIVING METHODS OF LED MODULE

Operating Area

XLC-60-H-MA

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (4)

CONSTANT POWER TABLE
XLC-60-H-MA is a multiple-stage constant power driver, selection of output current through DIP switch setting is exhibited below.

Vo Io              DIP S.W 1 2 3
9~54V 900mA —- —- —-
9~54V 1050mA —- —- ON
9~50V 1200mA —- ON —-
9~46V 1300mA —- ON ON
9~43V 1400mA(default) ON —- —-
9~40V 1500mA ON —- ON
9~38V 1600mA ON ON —-
9~36V 1700mA ON ON ON

Note: The operating voltage range which show on this table is recommend to use.

PWM OUTPUT DIMMING PRINCIPLE

  • For 12V124V148V PWM style output dimming
  • Dimming is achieved by varying the duty cycle of the output current.

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (5)

OUTPUT LOAD vs TEMPERATURE

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (6)

  • STATIC CHARACTERISTIC
  • LIFE TIME

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (7)

TOTAL HARMONIC DISTORTION (THD)

  • XLC-60-H-MA Modie, Tcase at 750C

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (8)

POWER FACTOR PF CHARACTERISTIC

XLC-60-H-MA Modie, Tcase at 750C

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (9)

A EFFICIENCY vs LOAD

  • XLC-60-H-MA series possess superior working efficiency that up to 90% can be reached in field applications.
  • XLC-60-H-MA Modie, Tcase at 750C

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (10)

MECHANICAL SPECIFICATION

XLC-60-MA series Built-in Type

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (11)

XLC-60-MAS series Independent Type

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (12)

LED indicator

Flash slowly Bluetooth Broadcast running
Flash quickly Factory Reset running.
Constantly ON Matter wireless connected
Constantly OFF Matter wireless disconnected and Bluetooth Broadcast OFF

FACTORY RESET

By RESET BUTTON
Press and hold the reset button for 10 seconds. When the LED indicator flashes quickly, release the button. The factory reset will then be completed.

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (13)

By AC ON/OFF
To perform a factory reset through AC ON/OFF, the following process must be strictly followed. If the AC ON/OFF process is correct, the output light will flash for 15 seconds. When the flashing stop, it means the factory reset is completed. This operation is consistent with the factory reset effect performed by long-pressing the reset button.

AC ON/OFF process to execute factory reset:

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (14)

Phase Duration AC status
1 10-15s ON
2 >30s OFF
3 2-5s ON
4 >30s OFF
5 10-15s ON
6 >30s OFF
7 2-5s ON
8 >30s OFF
9 2-5s ON
10 >30s OFF
11 >25s ON(should wait until output light stop flashing)

If there is a malfunction in the ‘AC ON/OFF process’, the process can be reset by the following method, starting from stage 1 again.

  • Method 1 : AC ON time exceeds 25 seconds
  • Method 2: AC ON times for 2-5s and twice

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (15)

PLACEMENT
Matter device has an integrated antenna for easy integration. In order to maximize the range in every direction, some design guidelines should be taken into consideration when mounting the device.

The antenna positions of the device are shown in the figure below:

MEAN-WELL-XLC-60-MA-60W-Multiple-Stage-Constant-Power-Constant-Voltage-LED-Driver-fig- (16)

  • Keep the device as far away as possible from vertical metal structures.
  • When the device is mounted on a metal plate, the antenna should not be obscured, and there needs to be a cutout under the antenna to ensure that the RF signal can be transmitted.
  • The device’s communication range may be influenced by environmental factors and installation positioning, necessitating on-site adjustments and testing.

Installation Manual
Please refer to : http://www.meanwell.com/manual.html

FAQs

Q: How do I select the output voltage?
A: The output voltage (12/24/48V) can be selected by using the DIP switch on the device.

Q: What should I do if the device malfunctions during the AC ON/OFF process?
A: Follow the reset methods mentioned in the user manual to reset the AC ON/OFF process.

Q: How can I maximize the communication range of the device?
A: Follow the placement guidelines provided in the manual to ensure optimal communication range.