matt E SP-EVCP-RC Single Phase Voltage Monitoring

matt E SP-EVCP-RC Single Phase Voltage Monitoring

Important Information

The SP-EVCP-RC from matt:e incorporates our unique monitoring device that disconnects all poles including CPC in the event of a broken Neutral fault in line with Regulation 722.411.4.1 (iv) and has the additional functionality for load curtailment in line with Regulation 722.311.201, isolating the charge point from the supply once the house consumption rises above the pre-set limit and automatically restores the power to the charge point when the load falls back within a satisfactory level.

Creating a simple, single connection centre that allows for connection to the existing PME earthing facility without the use of Earth electrodes that saves time during survey and installation while offering a safe alternative for your work force.

Product Features

  • Built in matt: e technology
  • BS: 7671 2018 Amendment 1 2020 compliant
  • NO EARTH ELECTRODES REQUIRED
  • Load management with hard wired CT, factory set at 60A,80A or 100A
  • CT with simple plug and play connection
  • Built in 32amp Double Pole Type A RCBO
  • Standard 3 Year parts warranty
  • Mild steel IP2X enclosure
  • Designed and Built in the UK

Dimension

Description Single-phase Voltage Monitoring and Protection Unit
Input Volts Nominal input voltage single-phase 230V 50Hz
Max Load 32 amps
Load Management Pre set at 60A, 80, 100A
CT Cable Length Pre set at 60A, 80, 100A
CT Cable Length 1m
Cable Entry Facility Bottom, 1 x 42mm 2 x 25mm 1 x 16mm
Terminal Capacity In Out
L/N: 2.5mm2 -25mm2 L/N 2.5mm2 – 10mm2
E: 2.5mm2 —16mm2 E: 2.5mm2 – 10mm2
Dimensions ( H x W x D ) 169mm x 182mm x 111mm
Weight Approximately 3kG
Enclosure Mild Steel Powder Coated
Ingress Protection IP2X
Warranty The matt:e SP-EVCP-RC is guaranteed for a period of 3 years from the date of purchase. This warranty is limited to the replacement of faulty components only.

Customer Support

t: 01543 227290 e: info@matt-e.co.uk w: www.matt-e.co.uk
matt: e Ltd, Unit 5 Common Barn Farm Tamworth Road Lichfield WS14 9PX

Logo

Documents / Resources

matt E SP-EVCP-RC Single Phase Voltage Monitoring [pdf] Owner's Manual
SP-EVCP-RC Single Phase Voltage Monitoring, SP-EVCP-RC, Single Phase Voltage Monitoring, Phase Voltage Monitoring, Voltage Monitoring

References

Leave a comment

Your email address will not be published. Required fields are marked *