MASTERBUILT MB20041223 Temperature Probe Kit Installation Guide

MB20041223 Temperature Probe Kit

Product Specifications:

  • Product Name: Temperature Probe Kit, GSGXT
  • Model Numbers: MB20041223, MB20043024

Product Usage Instructions:

1. Preparing the Grill:

Remove all cooking grates and warming racks from the grill.

2. Accessing the Temperature Probe:

  1. Unscrew the shutdown flap handle located on the grill.
  2. Remove the 3 screws on the shutdown flap hopper shroud and take
    off the shroud.

3. Disconnecting Old Temperature Probe:

  1. Remove the 4 thumb screws from the back of the controller to
    access it.
  2. Take out the controller by removing the 6 screws on its back
    and rear plate.
  3. Disconnect the temperature probe (yellow wire) from the
    controller.
  4. Disconnect two black and white wire connections on the side of
    the controller.

4. Removing Old Probe Assembly:

  1. Remove the temperature probe and bracket assembly (2 screws)
    from the rear of the grill.
  2. Take out the grommet securing the assembly.

5. Installing New Temperature Probe:

  1. Secure the new temperature probe with screws in place of the
    old one.
  2. Route the new temperature probe through the grill and secure a
    new grommet in place.
  3. Connect the new temperature probe to the controller.

6. Completing Installation:

For the remaining installation, follow all steps in reverse
order to ensure proper reassembly of the grill components.

Frequently Asked Questions (FAQ):

Q: Do I need any special tools for installing the temperature
probe kit?

A: The installation of the temperature probe kit requires basic
tools like screwdrivers for unscrewing components and securing the
new probe in place. No special tools are needed.

Q: Can I use this temperature probe kit with any type of
grill?

A: The Temperature Probe Kit, GSGXT, is designed to be
compatible with specific grill models. Ensure that your grill model
matches the compatibility list provided before installation.

“`

Temperature Probe Kit, GSGXT
MB20041223, MB20043024
CAUTION
· Always remove plug from outlet before servicing your grill. · Make sure your grill has fully cooled to avoid burns. · Some components may have sharp edges. Use caution to avoid injury.
Note: Your grill may vary from images shown

1

2

3

Remove all cooking grates and warming racks.
4

Unscrew the shutdown flap handle.

Remove 3 screws on the shutdown flap hopper shroud. Remove the shroud.

5

6

TEMPERATURE PROBE

Remove the 4 thumb screws from the back of the controller. Remove the controller

Remove the 6 screws on the back of the controller and remove the rear plate.
Disconnect the temperature probe from the controller. This should be the yellow wire.

Disconnect two black and white wire connections on the side of the controller.

601861 240906-GH

7

8

9

NUT

GROMMET

Remove the temp probe and bracket assembly (2 screws) from the rear
of the grill. Remove the grommet

Secure the temp probe bracket (2 Screws).

10

11

SCREW
Secure the new temp probe.

GROMMET

Route the temperature probe through the grill and secure the new grommet.

Connect the new temperature probe to the controller

For the remaining installation, follow all steps in reverse.